Conductive Hydrogel-Based Electrochemical Sensor: A Soft Platform for Capturing Analyte

被引:50
作者
Fu, Li [1 ]
Yu, Aimin [2 ]
Lai, Guosong [3 ]
机构
[1] Hangzhou Dianzi Univ, Coll Mat & Environm Engn, Key Lab Novel Mat Sensor Zhejiang Prov, Hangzhou 310018, Peoples R China
[2] Swinburne Univ Technol, Fac Sci Engn & Technol, Dept Chem & Biotechnol, Hawthorn, Vic 3122, Australia
[3] Hubei Normal Univ, Coll Chem & Chem Engn, Hubei Key Lab Pollutant Anal & Reuse Technol, Huangshi 435002, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
conductive hydrogels; electrochemistry; quantitative analysis; chemometrics; nanocomposites; analytical chemistry; food analysis; drug testing; GLASSY-CARBON ELECTRODE; GRAPHENE OXIDE HYDROGEL; CROSS-LINKED HYDROGEL; BIOSENSING PLATFORM; GOLD NANOPARTICLES; ASCORBIC-ACID; DNA HYDROGEL; AMPEROMETRIC DETERMINATION; POLYPYRROLE HYDROGELS; ANTIOXIDANT ACTIVITY;
D O I
10.3390/chemosensors9100282
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrode modifications for electrochemical sensors attract a lot of attention every year. Among them, hydrogels are a relatively special class of electrode modifier. Since hydrogels often contain polymers, even though they are conductive polymers, they are not ideal electrode modifiers because of their poor conductivity. However, the micro-aqueous environment and the three-dimensional structure of hydrogels are an excellent platform for immobilizing bioactive molecules and maintaining their activity. This gives the hydrogel-modified electrochemical sensor the potential to perform specific recognition. At the same time, the rapid development of nanomaterials also makes the composite hydrogel have good electrical conductivity. This has led many scientists to become interested in hydrogel-based electrochemical sensors. In this review, we summarize the development process of hydrogel-based electrochemical sensors, starting from 2000. Hydrogel-based electrochemical sensors were initially used only as a carrier for biomolecules, mostly for loading enzymes and for specific recognition. With the widespread use of noble metal nanoparticles and carbon materials, hydrogels can now be used to prepare enzyme-free sensors. Although there are some sporadic studies on the use of hydrogels for practical applications, the vast majority of reports are still limited to the detection of common model molecules, such as glucose and H2O2. In the review, we classify hydrogels according to their different conducting strategies, and present the current status of the application of different hydrogels in electrochemical sensors. We also summarize the advantages and shortcomings of hydrogel-based electrochemical sensors. In addition, future prospects regarding hydrogel for electrochemical sensor use have been provided at the end.
引用
收藏
页数:18
相关论文
共 125 条
[1]   Hydrogel: Preparation, characterization, and applications: A review [J].
Ahmed, Enas M. .
JOURNAL OF ADVANCED RESEARCH, 2015, 6 (02) :105-121
[2]   A novel glucose sensor using lutetium phthalocyanine as redox mediator in reduced graphene oxide conducting polymer multifunctional hydrogel [J].
Al-Sagur, H. ;
Komathi, S. ;
Khan, M. A. ;
Gurek, A. G. ;
Hassan, A. .
BIOSENSORS & BIOELECTRONICS, 2017, 92 :638-645
[3]   Electrically conductive, mechanically robust, pH-sensitive graphene/polymer composite hydrogels [J].
Alam, Ashraful ;
Meng, Qingshi ;
Shi, Ge ;
Arabi, Sherif ;
Ma, Jun ;
Zhao, Ning ;
Kuan, Hsu-Chiang .
COMPOSITES SCIENCE AND TECHNOLOGY, 2016, 127 :119-126
[4]   Graphene oxide/conducting polymer composite hydrogels [J].
Bai, Hua ;
Sheng, Kaixuan ;
Zhang, Pengfei ;
Li, Chun ;
Shi, Gaoquan .
JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (46) :18653-18658
[5]   Electrodes modified with 3D graphene composites: a review on methods for preparation, properties and sensing applications [J].
Baig, Nadeem ;
Saleh, Tawfik A. .
MICROCHIMICA ACTA, 2018, 185 (06)
[6]   Disposable MMP-9 sensor based on the degradation of peptide cross-linked hydrogel films using electrochemical impedance spectroscopy [J].
Biela, Anna ;
Watkinson, Michael ;
Meier, Ute C. ;
Baker, David ;
Giovannoni, Gavin ;
Becer, C. Remzi ;
Krause, Steffi .
BIOSENSORS & BIOELECTRONICS, 2015, 68 :660-667
[7]   Polypyrrole-hydrogel composites for the construction of clinically important biosensors [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :53-59
[8]   Chemical and biological sensors based on electrochemical detection using conducting electroactive polymers [J].
Brahim, S ;
Wilson, AM ;
Narinesingh, D ;
Iwuoha, E ;
Guiseppi-Elie, A .
MICROCHIMICA ACTA, 2003, 143 (2-3) :123-137
[9]  
Burrs SL, 2015, ANALYST, V140, P1466, DOI [10.1039/c4an01788a, 10.1039/C4AN01788A]
[10]   An electrochemical impedance biosensor for Hg2+ detection based on DNA hydrogel by coupling with DNAzyme-assisted target recycling and hybridization chain reaction [J].
Cai, Wei ;
Xie, Shunbi ;
Zhang, Jin ;
Tang, Dianyong ;
Tang, Ying .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :466-472