Effect of air exhaust location on surgical site particle distribution in an operating room

被引:22
作者
Agirman, Aleyna [1 ]
Cetin, Yunus Emre [2 ]
Avci, Mete [3 ]
Aydin, Orhan [1 ]
机构
[1] Karadeniz Tech Univ, Dept Mech Engn, TR-61080 Trabzon, Turkey
[2] Karadeniz Tech Univ, Arsin Vocat Sch, TR-61910 Arsin Trabzon, Turkey
[3] Recep Tayyip Erdogan Univ, Dept Mech Engn, TR-53100 Rize, Turkey
关键词
operating room; exhaust outlet; particle deposition; CFD; VENTILATION PERFORMANCE; AIRBORNE PARTICLES; DOOR OPENINGS; FLOW; DISPERSION; INFECTION; TRANSPORT; IMPACT; DISPLACEMENT; THEATER;
D O I
10.1007/s12273-020-0642-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates effect of exhaust outlet location on airflow and particle distribution in an operating room with laminar ventilation system (LAF) via computational fluid dynamics (CFD). Four different exhaust opening configurations are comparatively examined: floor level, central level, ceiling level and floor & ceiling level. Three different particle diameters (5,10 and 20 mu m) are considered for a constant value of the air change rate (30 ACH). Deposited particle numbers to operating table and to instrument table are given and compared for different particle diameters and exhaust outlet cases. It is shown that the exhaust configuration in which both floor & ceiling level air outlets employed together shows the best performance in terms of lowest particle deposition to the operating table. For this case, compared to original floor level exhaust outlet design, the total number of particles deposited on the operating table decreased by 64% for the smallest particle diameter (5 mu m) and 26% for the largest particle diameter (20 mu m).
引用
收藏
页码:979 / 988
页数:10
相关论文
共 67 条
  • [1] Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system
    Aganovic, Amar
    Cao, Guangyu
    Stenstad, Liv-Inger
    Skogas, Jan Gunnar
    [J]. BUILDING AND ENVIRONMENT, 2017, 126 : 42 - 53
  • [2] Agirman Aleyna, 2019, E3S Web of Conferences, V111, DOI 10.1051/e3sconf/201911101032
  • [3] A numerical study on the effects of exhaust locations on energy consumption and thermal environment in an office room served by displacement ventilation
    Ahmed, Ahmed Qasim
    Gao, Shian
    Kareem, Ali Khaleel
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 117 : 74 - 85
  • [4] Analyzing the risk factors influencing surgical site infections: the site of environmental factors
    Alfonso-Sanchez, Jose L.
    Martinez, Isabel M.
    Martin-Moreno, Jose M.
    Gonzalez, Ricardo S.
    Botia, Francisco
    [J]. CANADIAN JOURNAL OF SURGERY, 2017, 60 (03) : 155 - 161
  • [5] Burden of endemic health-care-associated infection in developing countries: systematic review and meta-analysis
    Allegranzi, Benedetta
    Nejad, Sepideh Bagheri
    Combescure, Christophe
    Graafmans, Wilco
    Attar, Homo
    Donaldson, Liam
    Pittet, Didier
    [J]. LANCET, 2011, 377 (9761) : 228 - 241
  • [6] [Anonymous], 2008, VENTILATION AIR COND
  • [7] [Anonymous], 2013, ANSYS FLUENT THEOR G
  • [8] [Anonymous], 2016, GLOB GUID PREV SURG
  • [9] Balocco C., 2014, J BIOMED SCI ENG, V2014, DOI [10.4236/jbise.2014.711086, DOI 10.4236/JBISE.2014.711086, DOI 10.1161/CIR.0b013e3181dbece1]
  • [10] BELANI KG, 2013, ANESTHESIA ANALGESIA