Toward Isolation of Palytoxins: Liquid Chromatography Coupled to Low- or High-Resolution Mass Spectrometry for the Study on the Impact of Drying Techniques, Solvents and Materials

被引:4
|
作者
Mazzeo, Antonia [1 ]
Varra, Michela [1 ]
Tartaglione, Luciana [1 ,2 ]
Ciminiello, Patrizia [1 ]
Zendong, Zita [3 ]
Hess, Philipp [3 ]
Dell'Aversano, Carmela [1 ,2 ]
机构
[1] Univ Napoli Federico II, Sch Med & Surg, Dept Pharm, Via D Montesano 49, I-80131 Naples, Italy
[2] CoNISMa Natl Interuniv Consortium Marine Sci, Piazzale Flaminio 9, I-00196 Rome, Italy
[3] IFREMER, DYNECO, Lab Phycotoxines, Rue Iile Yeu, F-44311 Nantes, France
关键词
palytoxin; LC-HRMS; evaporation; stability; palytoxin methyl ester; OVATOXIN-A; STRUCTURAL INSIGHTS; PUTATIVE PALYTOXIN; TOXIN PROFILE; OSTREOPSIS; ACCUMULATION; ELUCIDATION; SEAFOOD; ANALOG; SHAPE;
D O I
10.3390/toxins13090650
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Palytoxin (PLTX) and its congeners are emerging toxins held responsible for a number of human poisonings following the inhalation of toxic aerosols, skin contact, or the ingestion of contaminated seafood. Despite the strong structural analogies, the relative toxic potencies of PLTX congeners are quite different, making it necessary to isolate them individually in sufficient amounts for toxicological and analytical purposes. Previous studies showed poor PLTX recoveries with a dramatic decrease in PLTX yield throughout each purification step. In view of a large-scale preparative work aimed at the preparation of PLTX reference material, we have investigated evaporation as a critical-although unavoidable-step that heavily affects overall recoveries. The experiments were carried out in two laboratories using different liquid chromatography-mass spectrometry (LC-MS) instruments, with either unit or high resolution. Palytoxin behaved differently when concentrated to a minimum volume rather than when evaporated to complete dryness. The recoveries strongly depended on the solubility as well as on the material of the used container. The LC-MS analyses of PLTX dissolved in aqueous organic blends proved to give a peak intensity higher then when dissolved in pure water. After drying, the PLTX adsorption appeared stronger on glass surfaces than on plastic materials. However, both the solvents used to dilute PLTX and that used for re-dissolution had an important role. A quantitative recovery (97%) was achieved when completely drying 80% aqueous EtOH solutions of PLTX under N-2-stream in Teflon. The stability of PLTX in acids was also investigated. Although PLTX was quite stable in 0.2% acetic acid solutions, upon exposure to stronger acids (pH < 2.66), degradation products were observed, among which a PLTX methyl-ester was identified.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Occurrence of cytostatic compounds in hospital effluents and wastewaters, determined by liquid chromatography coupled to high-resolution mass spectrometry
    Cristian Gómez-Canela
    Francesc Ventura
    Josep Caixach
    Silvia Lacorte
    Analytical and Bioanalytical Chemistry, 2014, 406 : 3801 - 3814
  • [42] Identification of Auxin Metabolites in Brassicaceae by Ultra-Performance Liquid Chromatography Coupled with High-Resolution Mass Spectrometry
    Revelou, Panagiota-Kyriaki
    Kokotou, Maroula G.
    Constantinou-Kokotou, Violetta
    MOLECULES, 2019, 24 (14):
  • [43] Analysis of bioactive peptides by liquid chromatography high-resolution electrospray mass spectrometry
    DAgostino, PA
    Hancock, JR
    Provost, LR
    JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 77 - 85
  • [44] Identification of glycated sites in ovalbumin under freeze-drying processing by liquid chromatography high-resolution mass spectrometry
    Tu, Zong-cai
    Zhong, Bi-zhen
    Wang, Hui
    FOOD CHEMISTRY, 2017, 226 : 1 - 7
  • [45] Use of liquid chromatography coupled to low- and high-resolution linear ion trap mass spectrometry for studying the metabolism of paynantheine, an alkaloid of the herbal drug Kratom in rat and human urine
    Philipp, Anika A.
    Wissenbach, Dirk K.
    Weber, Armin. A.
    Zapp, Josef
    Zoerntlein, Siegfried W.
    Kanogsunthornrat, Jidapha
    Maurer, Hans H.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2379 - 2391
  • [46] Determination of Synthetic Cathinones in Urine and Oral Fluid by Liquid Chromatography High-Resolution Mass Spectrometry and Low-Resolution Mass Spectrometry: A Method Comparison
    Pascual-Caro, Sergi
    Borrull, Francesc
    Aguilar, Carme
    Calull, Marta
    SEPARATIONS, 2020, 7 (04) : 1 - 14
  • [47] Use of liquid chromatography coupled to low- and high-resolution linear ion trap mass spectrometry for studying the metabolism of paynantheine, an alkaloid of the herbal drug Kratom in rat and human urine
    Anika A. Philipp
    Dirk K. Wissenbach
    Armin. A. Weber
    Josef Zapp
    Siegfried W. Zoerntlein
    Jidapha Kanogsunthornrat
    Hans H. Maurer
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2379 - 2391
  • [48] Improving Resolution of Isomeric Flavonoids and Their Glycosides Using Two-Dimensional Liquid Chromatography Coupled With High-Resolution Mass Spectrometry
    Pua, Aileen
    Goh, Rui Min Vivian
    Ee, Kim-Huey
    Huang, Yunle
    Liu, Shao Quan
    Lassabliere, Benjamin
    Yu, Bin
    CHROMATOGRAPHIA, 2021, 84 (05) : 507 - 515
  • [49] Comparative study of low- versus high-resolution liquid chromatography-mass spectrometric strategies for measuring perfluorinated contaminants in fish
    Kadar, H.
    Veyrand, B.
    Antignac, J. -P.
    Durand, S.
    Monteau, F.
    Le Bizec, B.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (09): : 1261 - 1273
  • [50] Improving Resolution of Isomeric Flavonoids and Their Glycosides Using Two-Dimensional Liquid Chromatography Coupled With High-Resolution Mass Spectrometry
    Aileen Pua
    Rui Min Vivian Goh
    Kim-Huey Ee
    Yunle Huang
    Shao Quan Liu
    Benjamin Lassabliere
    Bin Yu
    Chromatographia, 2021, 84 : 507 - 515