24-hour continuous sound-level measurements conducted in Spanish urban areas

被引:7
|
作者
Garcia, A [1 ]
Garrigues, JV [1 ]
机构
[1] Dept Fis Aplicada, Valencia 46100, Spain
关键词
D O I
10.3397/1.2828468
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Environmental sound measurements have been carried out during recent years in different cities and locations in Spain. The sound levels have been continuously sampled over 24-hour periods using a noise level analyzer. The data presented in this paper have been obtained from a total of 12 000 hours of measurement. All the information collected has been used to investigate the time patterns of the hourly sound levels under a wide range of conditions and to evaluate the relationships between several noise descriptors in urban areas. (C) 1998 Institute of Noise Control Engineering.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [1] 24 hour measurements of noise levels in urban areas
    Garcia, A
    Garrigues, JV
    INTER-NOISE 96 - THE 1996 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, 25TH ANNIVERSARY CONGRESS - LIVERPOOL, PROCEEDINGS, BOOKS 1-6: NOISE CONTROL - THE NEXT 25 YEARS, 1996, : 2057 - 2060
  • [2] 24 Hour Measurements of Noise Levels in Urban Areas
    Proc Int Conf Noise Control Eng, 4 (2057):
  • [3] Are preservatives necessary in 24-hour urine measurements?
    Yilmaz, Guelsen
    Yilmaz, Fatma Meric
    Hakligor, Aylin
    Yucel, Dogan
    CLINICAL BIOCHEMISTRY, 2008, 41 (10-11) : 899 - 901
  • [4] A 24-hour continuous infusion study of bivalirudin in the rat
    Gleason, TG
    Chengelis, CP
    Jackson, CB
    Lindstrom, P
    INTERNATIONAL JOURNAL OF TOXICOLOGY, 2003, 22 (03) : 195 - 206
  • [5] Continuous 24-hour measurement of middle ear pressure
    Tideholm, B
    Jonsson, S
    Carlborg, B
    Welinder, R
    Grenner, J
    ACTA OTO-LARYNGOLOGICA, 1996, 116 (04) : 581 - 588
  • [6] EFFECTS OF GROUND COVER AND REFLECTING SURFACES ON SOUND-LEVEL METER MEASUREMENTS
    PROCTOR, TM
    MAGRAB, EB
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1975, 58 : S70 - S70
  • [7] DEFRA answers questions on 24-hour cover in rural areas
    不详
    VETERINARY RECORD, 2007, 160 (17) : 563 - 563
  • [8] Demonstration of 24-hour continuous optical turbulence monitoring in a city
    Beesley, L. F.
    Griffiths, R.
    Hartley, K.
    Farley, O. J. D.
    Quatresooz, F.
    Rodriguez-gomez, A.
    Comeron, A.
    Townson, M.
    Alaluf, D.
    Osborn, J.
    OPTICS EXPRESS, 2025, 33 (05): : 10140 - 10149
  • [9] 24-HOUR CONTINUOUS TREMOR QUANTIFICATION BASED ON EMG RECORDING
    BACHER, M
    SCHOLZ, E
    DIENER, HC
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1989, 72 (02): : 176 - 183
  • [10] CONTINUOUS 24-HOUR ELECTROCARDIOGRAPHY IN THYROTOXICOSIS BEFORE AND AFTER TREATMENT
    NORTHCOTE, RJ
    MACFARLANE, P
    KESSON, CM
    BALLANTYNE, D
    AMERICAN HEART JOURNAL, 1986, 112 (02) : 339 - 344