Multi-objective optimization of inverse planning for accurate radiotherapy

被引:20
作者
Cao Rui-Fen [1 ,2 ]
Wu Yi-Can [1 ,2 ,3 ]
Pei Xi [1 ,2 ]
Jing Jia [1 ,3 ,5 ]
Li Guo-Li [4 ]
Cheng Meng-Yun [1 ,2 ]
Li Gui [1 ,2 ]
Hu Li-Qin [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[2] Engn Technol Res Ctr Accurate Radiotherapy, Hefei 230031, Peoples R China
[3] Univ Sci & Technol China, Sch Nucl Sci & Technol, Hefei 230027, Peoples R China
[4] Zhejiang Univ Technol, Hangzhou 310014, Zhejiang, Peoples R China
[5] Hefei Univ Technol, Hefei 230009, Peoples R China
关键词
inverse planning; multi-objective optimization; accurate radiotherapy;
D O I
10.1088/1674-1137/35/3/019
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The multi-objective optimization of inverse planning based on the Pareto solution set, according to the multi-objective character of inverse planning in accurate radiotherapy, was studied in this paper. Firstly, the clinical requirements of a treatment plan were transformed into a multi-objective optimization problem with multiple constraints. Then, the fast and elitist multi-objective Non-dominated Sorting Genetic Algorithm (NSGA-II) was introduced to optimize the problem. A clinical example was tested using this method. The results show that an obtained set of non-dominated solutions were uniformly distributed and the corresponding dose distribution of each solution not only approached the expected dose distribution, but also met the dose-volume constraints. It was indicated that the clinical requirements were better satisfied using the method and the planner could select the optimal treatment plan from the non-dominated solution set.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 11 条
[1]  
Cao RF, 2007, LECT NOTES ARTIF INT, V4682, P553
[2]  
[曹瑞芬 CAO Ruifen], 2007, [中华放射医学与防护杂志, Chinese Journal of Radiological Medicine and Protection], V27, P467
[3]   A fast and elitist multiobjective genetic algorithm: NSGA-II [J].
Deb, K ;
Pratap, A ;
Agarwal, S ;
Meyarivan, T .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2002, 6 (02) :182-197
[4]   Anatomy-based three-dimensional dose optimization in brachytherapy using multiobjective genetic algorithms [J].
Lahanas, M ;
Baltas, D ;
Zamboglou, N .
MEDICAL PHYSICS, 1999, 26 (09) :1904-1918
[5]  
LI GL, 2006, STUDY MULTIOBJECTIVE
[6]   A multi-objective hybrid genetic based optimization for external beam radiation [J].
Li, Guoli ;
Song, Gang ;
Wu, Yican ;
Zhang, Jian ;
Wang, Qunjing .
PLASMA SCIENCE & TECHNOLOGY, 2006, 8 (02) :234-236
[7]  
[李国丽 Li Guoli], 2006, [原子核物理评论, Nuclear physics review], V23, P233
[8]  
Li Guoli, 2007, Nuclear Techniques, V30, P222
[9]  
SONG G, 2008, HYBRID DOSE CALCULAT
[10]  
Wu YC, 2005, CHINESE J MED PHYS, V22, P283