CFD analysis for the performance improvement of a double pipe heat exchanger with twisted tape having triangular cut

被引:16
作者
Dandoutiya, Bhrant Kumar [1 ]
Kumar, Arvind [1 ]
机构
[1] Maulana Azad Natl Inst Technol, Dept Mech Engn, Bhopal, MP, India
关键词
Triangular cut; turbulent flow; twisted tape; nusselt number; friction factor; effectiveness; TPF; swirl flow; TRANSFER ENHANCEMENT; FRICTION FACTOR; V-CUT; FLOW; TUBE; INSERTS; DESIGN;
D O I
10.1080/15567036.2021.1946215
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper studied the thermal performance of a double pipe heat exchanger using triangular cut twisted tape. The triangular cut twisted tape used in the study has w/W of 0.31, 0.47, and 0.63, respectively. The range of Reynolds number undertaken for studies was in turbulent zone varying from 5500 to 15300. k-epsilon turbulence model has been used for computational studies. It has been found that the effect of twisted tape results in swirl flow in two regions near the tube wall, the twisted tape wall, and in the core region. Due to swirl phenomena, an improvement in fluid mixing was observed with the use of triangular cut twisted tape. The Nusselt number improved by about 2.45 times and the friction factor increased by 9.22 times as compared to plain tubes without twisted tape. The maximum value of 1.21 as thermal performance factor was observed at Reynolds number of 5500.
引用
收藏
页码:9266 / 9284
页数:19
相关论文
共 28 条
[1]   Numerical analysis of flow and heat transfer enhancement in a horizontal pipe with P-TT and V-Cut twisted tape [J].
Abed, Azher M. ;
Majdi, Hasan Sh ;
Hussein, Zainab ;
Fadhil, Doaa ;
Abdulkadhim, Ammar .
CASE STUDIES IN THERMAL ENGINEERING, 2018, 12 :749-758
[2]  
Dandoutiya BK., 2019, SSRN ELECT J, DOI [10.2139/ssrn.3442589, DOI 10.2139/SSRN.3442589]
[3]   Numerical design and investigation of heat transfer enhancement and performance for an annulus with continuous helical baffles in a double-pipe heat exchanger [J].
El Maakoul, Anas ;
Laknizi, Azzeddine ;
Saadeddine, Said ;
Ben Abdellah, Abdellatif ;
Meziane, Mohamed ;
El Metoui, Mustapha .
ENERGY CONVERSION AND MANAGEMENT, 2017, 133 :76-86
[4]   Experimental heat transfer and pressure drop study on typical, perforated, V-cut and U-cut twisted tapes in a helically corrugated heat exchanger [J].
Hasanpour, A. ;
Farhadi, M. ;
Sedighi, K. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 71 :126-136
[5]   Experimental study on heat transfer enhancement characteristics of tube with cross hollow twisted tape inserts [J].
He, Yan ;
Liu, Li ;
Li, Pengxiao ;
Ma, Lianxiang .
APPLIED THERMAL ENGINEERING, 2018, 131 :743-749
[6]   Effect of twisted tape inserts on heat transfer, friction factor of Fe3O4 nanofluids flow in a double pipe U-bend heat exchanger [J].
Kumar, N. T. Ravi ;
Bhramara, P. ;
Kirubeil, A. ;
Syam Sundar, L. ;
Singh, Manoj K. ;
Sousa, Antonio C. M. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2018, 95 :53-62
[7]   CFD analysis on heat and flow characteristics of double helically coiled tube heat exchanger handling MWCNT/water nanofluids [J].
Kumar, P. C. Mukesh ;
Chandrasekar, M. .
HELIYON, 2019, 5 (07)
[8]   HEAT-TRANSFER AND PRESSURE-DROP CORRELATIONS FOR TWISTED-TAPE INSERTS IN ISOTHERMAL TUBES .2. TRANSITION AND TURBULENT FLOWS [J].
MANGLIK, RM ;
BERGLES, AE .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1993, 115 (04) :890-896
[9]   CFD analysis on heat transfer and pressure drop characteristics of turbulent flow in a tube fitted with trapezoidal-cut twisted tape insert using Fe3O4 nano fluid [J].
Murali, G. ;
Nagendra, B. ;
Jaya, J. .
MATERIALS TODAY-PROCEEDINGS, 2020, 21 :313-319
[10]   Heat transfer and pressure drop characteristics in a circular tube fitted with and without V-cut twisted tape insert [J].
Murugesan, P. ;
Mayilsamy, K. ;
Suresh, S. ;
Srinivasan, P. S. S. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2011, 38 (03) :329-334