Thermal study of school buildings in winter conditions

被引:23
作者
Conceicao, E. Z. E. [1 ]
Lucio, M. M. J. R. [2 ]
机构
[1] Univ Algarve, FCMA, P-8005139 Faro, Portugal
[2] Reg Directory Educ Algarve, P-8000761 Faro, Portugal
关键词
building thermal behaviour; thermal comfort; air quality; numerical simulation;
D O I
10.1016/j.buildenv.2007.01.029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a thermal study of a school building with real occupation levels in winter conditions is presented and a software that evaluates the air quality and simulates the thermal response of buildings with complex topology in steady-state and transient conditions is used, After validation, the numerical model is used, in the first phase, to evaluate the occupants' comfort levels in several spaces, while in the second phase two solutions, to improve acceptable thermal comfort and air quality levels (1) the electric air-heating systems, with predicted mean vote control, and (2) three solar collectors, placed instead of the roof area, used to heat the air in uncomfortable spaces are studied. The software is based on energy and mass balance integral equations that considers all conductive, convective, radiative and massic phenomena and internal heat generation in the building. In the radiative phenomena, which are very important in this region, all shading effects, incident solar radiation and radiative exchanges in all indoor and outdoor surfaces will be considered, and the mass phenomena, which are very important in thermal and air quality studies, internal mass generation, mass exchanges among compartments and between them and external environment will be considered. The considered school building, located in the south of Portugal, has three levels, 97 compartments, 1277 main bodies and 211 windows with simple transparent glass. This simulation took place on a winter day with clear sky and with 800 occupants. In this study, where a project of a school building with acceptable thermal and air quality levels is presented, the solar radiation (very intense in this region) will be used in order to reduce the school building's energy consumption levels. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:782 / 792
页数:11
相关论文
共 19 条
[1]  
[Anonymous], TRANSFERENCIA CALOR
[2]  
*ANSI ASHRAE, 2004, 621 ANSI ASHRAE
[3]  
ASHRAE, 2005, ASHRAE HDB FUND
[4]  
BERNE P, 1994, ROOM VENT 1994 4 INT
[5]  
CAMMARATA G, 1994, P 3 INT C BUD HUNG
[6]  
CONCEICAO E, 2004, NUMERICAL STUDY THER
[7]  
CONCEICAO E, 2003, BUILDING SIMULATION, P11
[8]  
CONCEICAO EZE, 2005, 4 INT C COMP HEAT MA
[9]  
CORRADO C, 1995, P ATA C BOL IT
[10]  
Duffie JA., 1980, Solar engineering of thermal processes