Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base

被引:78
作者
Gholivand, M. B. [1 ]
Rahimi-Nasrabadi, M.
Ganjali, M. R.
Salavati-Niasari, M.
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Univ Tehran, Dept Chem, Tehran, Iran
[3] Kashan Univ, Dept Chem, Kashan, Iran
关键词
copper ion-selective electrode; potentiometry; bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB);
D O I
10.1016/j.talanta.2007.04.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB) was used as new N-N Schiffs base which plays the role of an excellent ion carrier in the construction of a Cu(II) membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 55% o-nitrophenyloctyl ether (NPOE), 7% BHAB and 8% oleic acid (OA). This sensor shows very good selectivity and sensitivity towards copper ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH and influence of additive anionic on the response properties of electrode were investigated. The electrode exhibits a Nernstian behavior (with slope of 29.6 mV per decade) over a very wide concentration range (5.0 x 10(-8) to 1.0 x 10(-2) mol L-1) with a detection limit of 3.0 x 10(-8) mol L-1 (2.56 ng mL(-1)). It shows relatively fast response time, in whole concentration range (< 15 s), and can be used for at least 12 weeks in the pH range of 2.8-5.8. The proposed sensor was successfully used to determination of copper in different water samples and as indicator electrode in potentiometric titration of copper ion with EDTA. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:553 / 560
页数:8
相关论文
共 48 条
[1]  
AMMAN D, 1991, ANAL CHIM ACTA, V171, P1380
[2]   Flow-injection spectrophotometric determination of copper(II) ion at low μg L-1 levels using 4-benzylpiperidinedithiocarbamate [J].
Asan, A ;
Andac, M ;
Isildak, I .
ANALYTICAL SCIENCES, 2001, 17 (09) :1125-1127
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   ORIGINS OF STRUCTURE AND ENERGETICS OF VAN-DER-WAALS CLUSTERS FROM AB-INITIO CALCULATIONS [J].
CHALASINSKI, G ;
SZCZESNIAK, MM .
CHEMICAL REVIEWS, 1994, 94 (07) :1723-1765
[5]  
Debye P, 1923, PHYS Z, V24, P305
[6]   Response of the jalpaite membrane copper(II) ion-selective electrode in marine waters [J].
DeMarco, R ;
Mackey, DJ ;
Zirino, A .
ELECTROANALYSIS, 1997, 9 (04) :330-334
[7]   SELECTIVITY-MODIFYING INFLUENCE OF ANIONIC SITES IN NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES [J].
EUGSTER, R ;
GEHRIG, PM ;
MORF, WE ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2285-2289
[8]   Copper-selective PVC membrane electrodes based on salens as carriers [J].
Fakhari, AR ;
Raji, TA ;
Naeimi, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02) :317-323
[9]  
FANG ZL, 1984, ANAL CHIM ACTA, V164, P41
[10]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282