Measurement of uranium isotope ratios in solid samples using laser ablation and diode laser-atomic absorption spectrometry

被引:59
作者
Quentmeier, A [1 ]
Bolshov, M [1 ]
Niemax, K [1 ]
机构
[1] Inst Spectrochem & Appl Spectrochem, D-44139 Dortmund, Germany
关键词
laser ablation; diode laser atomic absorption; isotope ratio; uranium;
D O I
10.1016/S0584-8547(00)00289-5
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A diode laser was used for the selective detection of U-235 and U-238 in a laser-induced plasma ignited by a Nd:YAG laser beam focused onto uranium oxide samples. The diode laser was sequentially tuned to the absorption lines of both isotopes (682.6736 nm for U-235, and 682.6913 nm for U-238). The absorption was measured on a pulse-to-pulse basis; the transient absorption peak was used as an analytical signal. Three samples were used with the relative abundance of the minor isotope U-235 of 0.204%, 0.407% and 0.714%. Optimal conditions for the detection of the minor isotope were obtained at a distance of similar to 3 mm from the sample surface, an argon pressure of similar to 3 kPa and for 7.5 mJ pulse energy of the Nd:YAG laser. Absorption in the wing of the broadened line of the U-238 isotope was found to be the main source of background for the measurement of the absorption of the minor isotope. The limit of detection of the minor isotope, evaluated on the basis of the 3 sigma criteria was estimated to be 100 mug g(-1). At the optimal conditions for the detection of the minor isotope optical thick conditions in the line centre of the main isotope were observed. Therefore, the isotope ratio measurements were performed by rationing the intensity of the net absorption signal measured in the line centre of the minor isotope and the absorption signal measured in the wing of the main isotope. This strategy was checked by determination of the isotope ratios for the two samples with depleted U-235 concentration using the sample with the natural isotope composition (0.714%) as a standard. The accuracy and precision for this measurement strategy was evaluated to approximately 10%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:45 / 55
页数:11
相关论文
共 50 条
  • [41] Laser ablation inductively coupled plasma atomic emission spectrometry for the determination of lanthanides and uranium in fuel reconditioning materials: Problems, solutions and implications
    Goodall, P
    Johnson, SG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) : 469 - 478
  • [42] Determination of elements in agricultural soils using IR laser ablation inductively coupled plasma atomic emission spectrometry
    Musil, P
    Otruba, V
    Kanicky, V
    Mermet, JM
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (11) : 1747 - 1758
  • [43] Analysis of liquid samples using dried-droplet laser ablation inductively coupled plasma mass spectrometry
    Do, Trong-Mui
    Hsieh, Hui-Fang
    Chang, Wei-Ciang
    Chang, E. -E.
    Wang, Chu-Fang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (08) : 610 - 618
  • [44] Determination of iron and copper in old manuscripts by slurry sampling graphite furnace atomic absorption spectrometry and laser ablation inductively coupled plasma mass spectrometry
    Wagner, B
    Garbos, S
    Bulska, E
    Hulanicki, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) : 797 - 804
  • [45] SIMULTANEOUS MULTIELEMENT ANALYSIS OF SOLID SAMPLES BY LASER-ABLATION MICROWAVE-INDUCED PLASMA OPTICAL-EMISSION SPECTROMETRY
    HIDDEMANN, L
    UEBBING, J
    CIOCAN, A
    DESSENNE, O
    NIEMAX, K
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 152 - 159
  • [46] Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS
    Zirakparvar, N. Alex
    Manard, Benjamin
    Hexel, Cole
    Dunlap, Daniel
    Metzger, Shalina
    Bostick, Debbie
    Bradley, Veronica
    Ticknor, Brian
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2023, 492
  • [47] Calibration Standard Samples for Multielement Analysis of Silicate Rocks Using Inductively Coupled Plasma Mass Spectrometry with Laser Ablation
    S. V. Palesskiy
    I. V. Nikolaeva
    Inorganic Materials, 2020, 56 : 1398 - 1408
  • [48] Microanalysis of Pb isotope ratios of low-Pb glass samples by femtosecond laser ablation-multiple ion counter-ICP-mass spectrometry (fsLA-MIC-ICP-MS)
    Chang, Qing
    Kimura, Jun-Ichi
    Miyazaki, Takashi
    Sasaki, Satoshi
    Kanazawa, Nobuyuki
    GEOCHEMICAL JOURNAL, 2014, 48 (03) : 309 - 320
  • [49] Calibration Standard Samples for Multielement Analysis of Silicate Rocks Using Inductively Coupled Plasma Mass Spectrometry with Laser Ablation
    Palesskiy, S. V.
    Nikolaeva, I. V.
    INORGANIC MATERIALS, 2020, 56 (14) : 1398 - 1408
  • [50] MEASUREMENT OF TRACE-ELEMENTS IN CERAMIC AND QUARTZ BY LASER ABLATION MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    CIOCAN, A
    HIDDEMANN, L
    UEBBING, J
    NIEMAX, K
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) : 273 - 278