Measurement of uranium isotope ratios in solid samples using laser ablation and diode laser-atomic absorption spectrometry

被引:59
|
作者
Quentmeier, A [1 ]
Bolshov, M [1 ]
Niemax, K [1 ]
机构
[1] Inst Spectrochem & Appl Spectrochem, D-44139 Dortmund, Germany
关键词
laser ablation; diode laser atomic absorption; isotope ratio; uranium;
D O I
10.1016/S0584-8547(00)00289-5
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A diode laser was used for the selective detection of U-235 and U-238 in a laser-induced plasma ignited by a Nd:YAG laser beam focused onto uranium oxide samples. The diode laser was sequentially tuned to the absorption lines of both isotopes (682.6736 nm for U-235, and 682.6913 nm for U-238). The absorption was measured on a pulse-to-pulse basis; the transient absorption peak was used as an analytical signal. Three samples were used with the relative abundance of the minor isotope U-235 of 0.204%, 0.407% and 0.714%. Optimal conditions for the detection of the minor isotope were obtained at a distance of similar to 3 mm from the sample surface, an argon pressure of similar to 3 kPa and for 7.5 mJ pulse energy of the Nd:YAG laser. Absorption in the wing of the broadened line of the U-238 isotope was found to be the main source of background for the measurement of the absorption of the minor isotope. The limit of detection of the minor isotope, evaluated on the basis of the 3 sigma criteria was estimated to be 100 mug g(-1). At the optimal conditions for the detection of the minor isotope optical thick conditions in the line centre of the main isotope were observed. Therefore, the isotope ratio measurements were performed by rationing the intensity of the net absorption signal measured in the line centre of the minor isotope and the absorption signal measured in the wing of the main isotope. This strategy was checked by determination of the isotope ratios for the two samples with depleted U-235 concentration using the sample with the natural isotope composition (0.714%) as a standard. The accuracy and precision for this measurement strategy was evaluated to approximately 10%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:45 / 55
页数:11
相关论文
共 50 条
  • [21] Isotopic uranium determination by inductively coupled plasma atomic emission spectrometry using conventional and laser ablation sample introduction
    Goodall, PS
    Johnson, SG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (01) : 57 - 60
  • [22] Estimation of boron isotope ratios using high resolution continuum source atomic absorption spectrometry
    Wiltsche, Helmar
    Prattes, Karl
    Zischka, Michael
    Knapp, Guenter
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (04) : 341 - 346
  • [23] Direct determination of lead isotope ratios by laser ablation-inductively coupled plasma-quadrupole mass spectrometry in lake sediment samples
    Aries, S
    Motelica-Heino, M
    Freydier, R
    Grezes, T
    Polvé, M
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3): : 387 - 398
  • [24] Isotope ratio analysis on micron-sized particles in complex matrices by Laser Ablation-Absorption Ratio Spectrometry
    Bushaw, B. A.
    Anheier, N. C., Jr.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (11-12) : 1259 - 1265
  • [25] Determination of tin isotope ratios in cassiterite by femtosecond laser ablation multicollector inductively coupled plasma mass spectrometry
    Schulze, Marie
    Ziegerick, Marco
    Horn, Ingo
    Weyer, Stefan
    Vogt, Carla
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 26 - 34
  • [26] Determination of uranium in seawater, biological samples and sediments using laser induced fluorescence spectrometry
    Dekun Huang
    Fangfang Deng
    Jianhua He
    Tao Yu
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1359 - 1363
  • [27] Determination of uranium in seawater, biological samples and sediments using laser induced fluorescence spectrometry
    Huang, Dekun
    Deng, Fangfang
    He, Jianhua
    Yu, Tao
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (02) : 1359 - 1363
  • [28] Application of laser ionization mass spectrometry for measurement of uranium isotope ratio in nuclear forensics and nuclear safeguards
    Wang, Fan
    Zhang, Yan
    Zhao, Yong-gang
    Guo, Dong-fa
    Xie, Sheng-kai
    Tan, Jing
    Li, Jin-ying
    Lu, Jie
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (09)
  • [29] Isotopic analysis and plasma diagnostics for lithium detection using combined laser ablation-tuneable diode laser absorption spectroscopy and laser-induced breakdown spectroscopy
    Hull, Gregory
    McNaghten, Edward D.
    Coffey, Paul
    Martin, Philip
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 177
  • [30] On-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry using a microflow nebulizer inserted in the laser ablation chamber
    Pickhardt, C
    Izmer, AV
    Zoriy, MV
    Schaumlöffel, D
    Becker, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 248 (03) : 136 - 141