Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

被引:23
作者
Ketelsen, Dominik [1 ]
Horger, Marius [1 ]
Buchgeister, Markus [2 ,3 ]
Fenchel, Michael [1 ]
Thomas, Christoph [1 ]
Boehringer, Nadine [1 ]
Schulze, Maximilian [1 ]
Tsiflikas, Ilias [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Dept Radiotherapy, D-72076 Tubingen, Germany
[3] Univ Hosp Tuebingen, Dept Radiooncol, D-72076 Tubingen, Germany
关键词
Perfusion CT; Tumor vascularity; Radiation exposure; Effective dose; 128-slice CT; Alderson-Rando phantom; PERFUSION COMPUTED-TOMOGRAPHY; CELL CARCINOMA; CHEST-PAIN; ANGIOGENESIS; REPRODUCIBILITY; CHEMOTHERAPY;
D O I
10.3348/kjr.2010.11.5.547
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. Materials and Methods: An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D-Perfusion-CT. Phantom measurements were performed on a 128-slice single-source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Results: Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Conclusion: Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans.
引用
收藏
页码:547 / 552
页数:6
相关论文
共 27 条
[11]   Comparison of liver perfusion parameters studied with conventional extravascular and experimental intravascular CT contrast agents [J].
Kapanen, Mika ;
Halavaara, Juba ;
Haekkinen, Anna-Maija .
ACADEMIC RADIOLOGY, 2007, 14 (08) :951-958
[12]   Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography [J].
Ketelsen, Dominik ;
Thomas, Christoph ;
Werner, Matthias ;
Luetkhoff, Marie H. ;
Buchgeister, Markus ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Burgstahler, Christof ;
Brodoefel, Harald ;
Kopp, Andreas F. ;
Claussen, Claus D. ;
Heuschmid, Martin .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (02) :274-279
[13]   Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography [J].
Ketelsen, Dominik ;
Luetkhoff, Marie H. ;
Thomas, Christoph ;
Werner, Matthias ;
Buchgeister, Markus ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Burgstahler, Christof ;
Kopp, Andreas F. ;
Claussen, Claus D. ;
Heuschmid, Martin .
EUROPEAN RADIOLOGY, 2009, 19 (01) :37-41
[14]   Imaging blood flow characteristics of hepatocellular carcinoma [J].
Kudo, M .
ONCOLOGY, 2002, 62 :48-56
[15]   Tumor angiogenesis: Molecular pathology, therapeutic targeting, and imaging [J].
Li, WW .
ACADEMIC RADIOLOGY, 2000, 7 (10) :800-811
[16]   Perfusion CT for the assessment of tumour vascularity: which protocol? [J].
Miles, KA .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 :S36-S42
[17]   Perfusion CT in Patients With Metastatic Renal Cell Carcinoma Treated With Interferon [J].
Ng, Chaan S. ;
Wang, Xiaohong ;
Faria, Silvana C. ;
Lin, E. ;
Charnsangavej, Chusilp ;
Tannir, Nizar M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :166-171
[18]   Quantitative assessment of lung cancer perfusion using MDCT: Does measurement reproducibility improve with greater tumor volume coverage? [J].
Ng, Quan Sing ;
Goh, Vicky ;
Klotz, Ernst ;
Fichte, Heinz ;
Saunders, Michele I. ;
Hoskin, Peter J. ;
Padhani, Anwar R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (04) :1079-1084
[19]   Perfusion CT: Noninvasive Surrogate Marker for Stratification of Pancreatic Cancer Response to Concurrent Chemo- and Radiation Therapy [J].
Park, Mi-Suk ;
Klotz, Ernst ;
Kim, Myeong-Jin ;
Song, Si Young ;
Park, Seung Woo ;
Cha, Seung-Whan ;
Lim, Joon Soek ;
Seong, Jinsil ;
Chung, Jae Bok ;
Kim, Ki Whang .
RADIOLOGY, 2009, 250 (01) :110-117
[20]  
Petralia G., 2010, Radiol med