Two quality control procedures on radiotherapy beam calibration and treatment planning system implementation

被引:1
|
作者
Piermattei, A
Azario, L
delle Canne, S
Fidanzio, A
Palazzoni, G
机构
[1] Univ Cattolica Sacro Cuore, Ist Fis, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Ist Radiol, Div Radioterapia, I-00168 Rome, Italy
关键词
dosimetry; quality control; radiotherapy;
D O I
10.1177/030089169808400210
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
New challenging dosimetric approaches, such as narrow beams and 3D algorithms, are being used in radiotherapy. In this paper two quality control (QC) procedures are reported, The first one concerns the QC of the dosimetry of small x-ray beams, generally carried out by using silicon detectors. The comparison of dose values obtained by a silicon diode, a dia mend detector, and radiochromic films shows that for x-ray beams of high energy, the silicon diode can give an overestimation of the output factors in phantom, up to 4%, This is due to the higher than unit density silicon diode and the surrounding envelope that restore the lateral electron equilibrium. About the 3D algorithms for breast treatment planning, a quality control test has been adopted to verify the accuracy of the computed dosimetry when "loss of scatter" occurs. The results show a sensible agreement (within 1.5%) between computed and experimental data.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 50 条
  • [41] Cone Beam Computed Tomography for Adaptive Radiotherapy Treatment Planning
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (04) : 377 - 385
  • [42] Determination of the optimum beam configurations in radiotherapy treatment planning.
    Rowbottom, CG
    Webb, S
    Oldham, M
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 306 - 309
  • [43] Optimization of beam-orientations in conformal radiotherapy treatment planning
    Rowbottom, CG
    MEDICAL PHYSICS, 1999, 26 (07) : 1406 - 1406
  • [44] Calibration technique of light beam quality measurement system
    Tian, Xiao-Qiang
    Zhou, Wen-Chao
    Peng, Yong
    Xie, Ping
    Hu, Xiao-Yang
    Zhongguo Jiguang/Chinese Journal of Lasers, 2006, 33 (SUPPL.): : 365 - 368
  • [45] Study and implementation of a simple beam shaping system for stereotactic radiotherapy
    Hacker, FL
    Bellerive, MR
    Kooy, HM
    Leber, ZH
    Shrieve, DC
    Tarbell, NJ
    Loeffler, JS
    RADIOSURGERY 1997, 1998, 2 : 228 - 235
  • [46] Cone Beam CT as a Quality Control Evaluation Tool for Conformal Lung Radiotherapy: What Have we Learnt about Treatment Planning and Delivery?
    Summers, H.
    Woolley, A.
    Holmes, M.
    Maxwell, N.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S54 - S55
  • [47] Scripts system implementation to improve quality management in radiotherapy
    Malave Chacon, B. A.
    Acosta Arteaga, J. C.
    Araguas Mora, P.
    Calderon Avila, V. D.
    Murcia Mejia, M.
    Arguis Pinel, M.
    Abella Cereigido, R.
    Hernandez Masgrau, V.
    Arenas Prat, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1451 - S1452
  • [48] Preliminary experience for the implementation of a Quality System in a radiotherapy department
    Verile, V
    Montagna, A
    Lapadula, L
    Castaldo, G
    Cerciello, V
    Luppino, S
    Iadanza, L
    Fusco, V
    TUMORI, 2001, 87 (04) : S146 - S146
  • [49] QUALITY ASSURANCE PROCEDURES IN EXTERNAL-BEAM RADIOTHERAPY AT THE LONDON-HOSPITAL
    LAKE, RA
    MORGAN, AK
    KLEVENHAGEN, SC
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 822 - 822
  • [50] The Implementation of an Advanced Treatment Planning Algorithm in the Treatment of Lung Cancer with Conventional Radiotherapy
    Pearson, M.
    Atherton, P.
    McMenemin, R.
    McDonald, F.
    Mazdai, G.
    Mulvenna, P.
    Lambert, G.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 168 - 174