An integrated fault phase selection scheme for double circuit lines on the same tower

被引:1
|
作者
Tian Shu [1 ]
Liu Fangfang [1 ]
机构
[1] Henan Polytech Univ, Sch Elect Engn & Automat, Jiaozuo 454003, Henan, Peoples R China
关键词
Double circuit lines; Fault component current; Phase selection; Crossing-line faults; The principle of equivalence;
D O I
10.4028/www.scientific.net/AMM.668-669.657
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For double circuit lines on the same tower, traditional phase selectors for single lines can not operate correctly in crossing-line faults. To ensure the performance of faults phase selection in the single lines and meanwhile achieve accurate phase selection in crossing-line faults, an integrated fault phase selection scheme based on fault component current is proposed. Firstly, faults are divided into single lines faults, same-name-phase crossing-line faults and non same-name-phase crossing-line faults, then the phase selection is classified. The process with adaptive capacity can automatically select the suitable phase selector not affected by fault types. Simulation results via PSCAD/EMTDC show that the phase selection scheme based on fault component current has good performances for different fault types, fault location and transition resistance.
引用
收藏
页码:657 / 660
页数:4
相关论文
共 50 条
  • [42] Study on A New Earth-fault Distance Protection for Four-circuit Transmission Lines on The Same Tower
    Guo Peiyu
    Yu Zhongan
    Tai Nengling
    Fan Chunju
    MECHATRONICS AND INTELLIGENT MATERIALS III, PTS 1-3, 2013, 706-708 : 1574 - +
  • [43] Propagation characteristics of fault travelling wave on double-circuit HVDC transmission lines partially on the same tower and its effect on travelling wave protection
    Li H.
    Guo L.
    Wang G.
    Liang Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (11): : 51 - 60
  • [44] Trip-out analysis of 110 kV double-circuit transmission lines and other lines partly on same tower
    Li, Li-Jun
    Zhu, Lin
    Wang, Jian
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (09): : 80 - 83
  • [45] A New Fault Location Scheme Based on Distribution Parameter for Four-Parallel Transmission Lines on Same Tower
    Xu Peng
    Liang Yuansheng
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 604 - +
  • [46] A Fault Phase Selection Scheme Based on Ratio of Opposite-direction-current to Same-direction-current for Parallel Lines
    Zhang Hai
    Sheng Wanxing
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [47] Lightning performance of 500 kV double-circuit line on same tower of the Three Gorges outgoing lines
    Huang, Weigang
    Zhongguo Dianli/Electric Power, 2000, 33 (05): : 57 - 61
  • [48] Fault Line Detection Methodology for Four Parallel Lines on the Same Tower
    Li, Botong
    Li, Yongli
    Yao, Chuang
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (04) : 1217 - 1228
  • [49] Improved Fault Phase Selection Scheme for Lines Terminated by Inverter Based Resources
    Xie, Yuhao
    Liu, Yu
    Nie, Yuan
    Lu, Dian
    Zhu, Yuxuan
    Zheng, Xiaodong
    2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [50] Non-contact fault location and identification method for same-tower multi-circuit transmission lines
    Yin, Tao
    Li, Jian
    Cai, Dongsheng
    Huang, Qi
    Hu, Weihao
    ENERGY REPORTS, 2021, 7 : 147 - 158