A temperature-dithering closed-loop interface circuit for a scanning thermal microscopy system

被引:13
|
作者
Lee, J [1 ]
Gianchandani, YB [1 ]
机构
[1] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
关键词
polyimide probe; scanning probe; thermal imaging;
D O I
10.1109/JMEMS.2004.839011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an interface circuit for low-frequency dithering measurements of resistor-based transducers. It is demonstrated in the context of a polyimide-shank scanning thermal microscopy probe which provides high thermal sensitivity and spatial resolution, but has a low bandwidth from both mechanical and thermal perspectives. These pose challenges in temperature dithering and control, as well as noise immunity. The circuit includes a proportional-integral controller and a demodulator, along with appropriate amplifier and filter blocks. It keeps the average temperature of the probe tip constant while synchronously detecting variations in the second harmonic of the modulated signal as the tip is scanned across the sample surface. Strategic choices in the circuit architecture and topology are evaluated, and the overall system including the sensor and the circuit is simulated. Measurements of the implemented system show that a signal-to-noise ratio (SNR) of 15.7 is achieved while scanning a photoresist sample of 218 nm thickness on a silicon substrate, and that the detection limit for variations in thermal conductance is < 3 pW/K.
引用
收藏
页码:44 / 53
页数:10
相关论文
共 50 条
  • [1] A scanning thermal microscopy system with a temperature dithering, servo-controlled interface circuit
    Lee, J
    Gianchandani, YB
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL IV: DIGITAL SIGNAL PROCESSING-COMPUTER AIDED NETWORK DESIGN-ADVANCED TECHNOLOGY, 2003, : 812 - 815
  • [2] CMOS interface circuit for closed-loop accelerometer
    Department of Microelectronics, Harbin Institute of Technology, Harbin 150001, China
    不详
    Guangxue Jingmi Gongcheng, 2009, 6 (1311-1315):
  • [3] High resolution interface circuit for closed-loop accelerometer
    Yin Liang
    Liu Xiaowei
    Chen Weiping
    Zhou Zhiping
    JOURNAL OF SEMICONDUCTORS, 2011, 32 (04)
  • [4] A Low-Noise CMOS Interface Circuit for Closed-Loop Accelerometer
    Yin, Liang
    Liu, Xiaowei
    Chen, Wei
    Chen, Weiping
    Zhou, Zhiping
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 502 - 505
  • [5] High resolution interface circuit for closed-loop accelerometer附视频
    尹亮
    刘晓为
    陈伟平
    周治平
    半导体学报, 2011, (04) : 118 - 125
  • [6] Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop
    Li, Qiang
    Ding, Lifeng
    Liu, Xiaowei
    Zhang, Qiang
    SENSORS, 2022, 22 (03)
  • [7] A Compact Closed-Loop Nanomanipulation System in Scanning Electron Microscope
    Zhang, Yan Liang
    Zhang, Yong
    Ru, Changhai
    Woo, Patrick
    Nakamura, Mitsuhiro
    Hoyle, David
    Cotton, Ian
    Sun, Yu
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011,
  • [8] Optical scanning system based on closed-loop galvanometer scanners
    Yang, Shaochen
    Atwood, Jim
    Zhang, Yungang
    Fu, Jingang
    Gong, Runze
    Jiguang Yu Hongwai/Laser and Infrared, 1997, 27 (05): : 297 - 300
  • [9] Design of interface circuit of closed-loop accelerometer with self-test function
    Liu, Yun-Tao
    Yin, Liang
    Chen, Wei-Ping
    Wu, Qun
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (06): : 1379 - 1384
  • [10] A Fully Differential Interface Circuit of Closed-loop Accelerometer with Force Feedback Linearization
    Hong-Lin Xu
    Hong-Na Liu
    Chong He
    Liang Yin
    Xiao-Wei Liu
    Journal of Harbin Institute of Technology(New series), 2014, (03) : 18 - 23