Simulation and experimental investigation of fluid flow in porous and non-porous solar air heaters

被引:36
作者
Rajarajeswari, K. [1 ]
Alok, Praveen [1 ]
Sreekumar, A. [1 ]
机构
[1] Pondicherry Univ, Ctr Green Energy Technol, Pondicherry 605014, India
关键词
Packed bed; Heat transfer; Friction factor; Solar energy; Fluid flow; Colburn factor; FRICTION FACTOR CORRELATIONS; PACKED-BED; WIRE MESH; THERMAL PERFORMANCE; ABSORBER PLATE; THERMOHYDRAULIC PERFORMANCE; EXTERNAL RECYCLE; DUCT; RIBS; ROUGHNESS;
D O I
10.1016/j.solener.2018.06.079
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The porous absorber in the solar air heater gives considerable temperature increment which is shown by computational fluid dynamic simulation and verified experimentally. Experimental analysis on porous (wire screen) and non-porous solar air heaters were carried out to study the heat transfer and friction factor characteristics. The analysis encompasses the investigation on effect of mass flow rate on air temperature increment, thermal efficiency and pressure drop across the test section. The heat transfer parameter is established in terms of Colburn (J(h)) factor for porous bed solar air heaters. The effect of friction factor on different geometries for a range of operating Reynolds number (194-591) is presented. Two wire screen matrix (WSM) solar air heater WSM-I and WSM-II were investigated which has different diameter, pitch and porosity. Thermal efficiency increased on introducing the packed wire-screen matrix diagonally in the air flow path. The increase in thermal efficiency for WSM-I and WSM-II were found to be 5-17% and 5-20% respectively with the mass flow rate ranging from 0.01 kg/s to 0.055 kg/s. The collector heat removal factor was found to be 0.95 +/- 0.021 for wire mesh absorber and 0.72 +/- 0.0073 for conventional type. The pressure drop across the length of the duct was studied to be in the range of 15 +/- 0.28 Pa to 17 +/- 0.28 Pa and 7 +/- 0.16 Pa to 11 +/- 0.28 Pa for WSM-I and WSM-II respectively and for conventional type it was between 5 +/- 0.20 Pa and 10 +/- 0.28 Pa.
引用
收藏
页码:258 / 270
页数:13
相关论文
共 40 条
[1]   Single and double pass solar air heaters with wire mesh as packing bed [J].
Aldabbagh, L. B. Y. ;
Egelioglu, F. ;
Ilkan, M. .
ENERGY, 2010, 35 (09) :3783-3787
[2]   Solar drying—A sustainable way of food processing [J].
Aravindh, M.A. ;
Sreekumar, A. .
Green Energy and Technology, 2015, 201 :27-46
[3]  
Aravindh MA, 2014, CURR SCI INDIA, V107, P350
[4]  
Aravindh M.A, 2014, RES CIV ENV ENG, V2, P160
[5]   DESIGN CONSIDERATIONS FOR SOLAR COLLECTORS WITH CYLINDRICAL GLASS HONEYCOMBS [J].
BUCHBERG, H ;
EDWARDS, DK .
SOLAR ENERGY, 1976, 18 (03) :193-203
[6]  
Chouchury C., 1991, RENEW ENERGY, V1
[7]   Investigations on thermal performance characteristics of wire screen packed bed solar air heater [J].
Chouksey, Vimal Ku ;
Sharma, S. P. .
SOLAR ENERGY, 2016, 132 :591-605
[8]   Thermal and thermohydraulic performance of counter and parallel flow packed bed solar air heaters [J].
Dhiman, Prashant ;
Thakur, N. S. ;
Chauhan, S. R. .
RENEWABLE ENERGY, 2012, 46 :259-268
[9]   An analytical model to predict the thermal performance of a novel parallel flow packed bed solar air heater [J].
Dhiman, Prashant ;
Thakur, N. S. ;
Kumar, Anoop ;
Singh, Satyender .
APPLIED ENERGY, 2011, 88 (06) :2157-2167
[10]   The effect of using transverse fins on a double pass flow solar air heater using wire mesh as an absorber [J].
El-khawajah, M. F. ;
Aldabbagh, L. B. Y. ;
Egelioglu, F. .
SOLAR ENERGY, 2011, 85 (07) :1479-1487