Low-dose computed tomography for axial spondyloarthritis: update on use and limitations

被引:17
作者
Lambert, Robert G. W. [1 ]
Hermann, Kay Geert A. [2 ]
Diekhoff, Torsten [2 ]
机构
[1] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[2] Charite Univ Med Berlin, Dept Radiol, Berlin, Germany
关键词
computed tomography; low-dose computed tomography; sacroiliac joint; sacroiliitis; spondyloarthritis; ANKYLOSING-SPONDYLITIS; CT; RADIOGRAPHY; SACROILIITIS; PROGRESSION;
D O I
10.1097/BOR.0000000000000803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of reviewRecent developments in low-dose computed tomography (ldCT) have greatly reduced radiation exposure levels. This article reviews what a ldCT is and its use and limitations for imaging axial spondyloarthritis.Recent findingsDetection of structural damage in bone with CT is far superior to radiography and ldCT of the sacroiliac joints (SIJ) can now be done at radiation exposure levels equivalent to, or even less than, conventional radiography. ldCT should be considered a 'first-choice' test for arthritis imaging, and wherever available, SIJ ldCT may completely replace conventional radiography. Radiation exposure in the spine with ldCT is lower than conventional CT. However, it is unclear whether the additional information regarding structural damage changes in the spine provided by ldCT will alter patient management sufficiently often to merit switching from spinal radiography to ldCT in routine clinical practice. In addition, ldCT cannot assess osteitis disease activity for which MRI remains the best test.SummaryldCT of the sacroiliac joints (SIJ) can be done at radiation exposure levels equivalent to, or less than, radiography and ldCT may completely replace SIJ radiography. However, the role of spinal ldCT for spondyloarthritis is not clear and MRI is far superior for detecting disease activity.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 50 条
  • [31] Use of low-dose computed tomography to assess pulmonary tuberculosis among healthcare workers in a tuberculosis hospital
    He Wei
    Chen BuDong
    Lv Yan
    Zhou Zhen
    Xu JinPing
    Lv PingXin
    Zhou XinHua
    Ning FengGang
    Li ChengHai
    Wang DongPo
    Zheng Jie
    贫困所致传染病(英文), 2017, 6 (02)
  • [32] Lung cancer screening with low-dose computed tomography
    Seijo Maceiras, Luis M.
    MEMO-MAGAZINE OF EUROPEAN MEDICAL ONCOLOGY, 2014, 7 (01) : 6 - 9
  • [33] Low-Dose Cardiovascular Computed Tomography: Where Are the Limits?
    Schoenhagen, Paul
    Thompson, Carla M.
    Halliburton, Sandra S.
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (01) : 17 - 23
  • [34] Use of low-dose computed tomography to assess pulmonary tuberculosis among healthcare workers in a tuberculosis hospital
    Wei He
    Bu-Dong Chen
    Yan Lv
    Zhen Zhou
    Jin-Ping Xu
    Ping-Xin Lv
    Xin-Hua Zhou
    Feng-Gang Ning
    Cheng-Hai Li
    Dong-Po Wang
    Jie Zheng
    Infectious Diseases of Poverty, 6
  • [35] Performance of 18F-sodium fluoride positron emission tomography with computed tomography to assess inflammatory and structural sacroiliitis on magnetic resonance imaging and computed tomography, respectively, in axial spondyloarthritis
    Raynal, Marie
    Bouderraoui, Fehd
    Ouichka, Remy
    Melchior, Julian
    Morel, Olivier
    Blum, Alain
    Chary-Valckenaere, Isabelle
    Sime, Willy Ngueyon
    Roch, Veronique
    Maksymowych, Walter
    Lambert, Robert G.
    Olivier, Pierre
    Loeuille, Damien
    ARTHRITIS RESEARCH & THERAPY, 2019, 21 (1)
  • [36] Cross-Domain Denoising for Low-Dose Multi-Frame Spiral Computed Tomography
    Lu, Yucheng
    Xu, Zhixin
    Choi, Moon Hyung
    Kim, Jimin
    Jung, Seung-Won
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (11) : 3949 - 3963
  • [37] Evaluation of chest radiography and low-dose computed tomography as valuable screening tools for thoracic diseases
    Kasuga, Ikuma
    Maezawa, Hiromi
    Gamo, Sanae
    Yokoe, Yoshimi
    Yanagihara, Yuri
    Sugiyama, Tomoko
    Tokura, Michiyo
    Okayama, Mayumi
    Ohtsubo, Osamu
    MEDICINE, 2022, 101 (29) : E29261
  • [38] Low-dose computed tomography image restoration using previous normal-dose scan
    Ma, Jianhua
    Huang, Jing
    Feng, Qianjin
    Zhang, Hua
    Lu, Hongbing
    Liang, Zhengrong
    Chen, Wufan
    MEDICAL PHYSICS, 2011, 38 (10) : 5713 - 5731
  • [39] Evaluation of optimal parameters for using low-dose computed tomography to diagnose urolithiasis
    Chen, Hui-Hsien
    Yu, Cheng-Ching
    Hsu, Fang-Yuh
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 242 - 246
  • [40] A LIMITED, LOW-DOSE COMPUTED-TOMOGRAPHY PROTOCOL TO EXAMINE THE SACROILIAC JOINTS
    FRIEDMAN, L
    SILBERBERG, PJ
    RAINBOW, A
    BUTLER, R
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1993, 44 (04): : 267 - 272