Reproducibility and reliability of measurements using a linear isokinetic dynamometer, Aristokin®

被引:0
|
作者
Lenaerts, A
Verbruggen, LA
Duquet, W
机构
[1] Acad Hosp, Rheumatol & Phys Therapy Univ, Brussels, Belgium
[2] Acad Hosp, Dept Motor Rehabil, Brussels, Belgium
[3] Free Univ Brussels, Dept Human Biometry & Biomech, Brussels, Belgium
来源
关键词
dynamometer; linear isokinetic; exercise; intra-observer reliability; intra-observer reproducibility; muscle; skeletal;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background. This study was performed to investigate the intraobserver reproducibility and reliability of measurements using a linear isokinetic dynamometer (Aristokin (R)). Methods. Sixteen female volunteers (age 18 to 23 years) participated in 4 test sessions, each consisting of 6 warming-up movements followed by 6 repetitions of 4 different movements. During each session, the subjects consecutively performed lifting movements by flexing elbows and shoulders (at 65 cm per see), total lifting movements with arms and legs (at 65 cm per see), and extension movements of the legs in sitting position (at 40 and 60 cm per see). The first 3 test sessions were performed at a weekly interval, the 4th was executed 4 weeks after the 3rd session. Force, power and explosivity (force developed per see) were recorded. Results. The intra-observer reproducibility was investigated of the 6 repetitions of the movements during each test session. The highest reproducibility for mean peak power and force was found in the combination of the 3rd, 4th, 5th and 6th measurement (intraclass correlation coefficient 0.85 to 0.99). Using this combination, the intra-observer reliability was investigated, defined as the consistency of results obtained during the 4 test sessions, performed at a weekly or longer interval. Comparison between these sessions showed that the results for mean force in the arm movement differed significantly (p=0.01) although a high between sessions correlation was found (0.96). Results for mean force and power for the 3 other movements were reliable, and no significant learning effect was observed. Lower reliability and reproducibility were observed for other parameters including explosivity and power and force at the first 0.25 see of the test movement. Conclusions. Even after standard warming-up movements, the first 2 out of 6 measurement repetitions during a test session are not reproducible and should not be used in calculations of the results. For the combination of the 3rd to 6th repetitions, a high reliability was found for the measurement of mean force and power of the total lifting movement and of the sitting leg extension movements repeated in 4 sessions over a period of 6 weeks.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 50 条
  • [21] Validity and reliability of a portable handheld dynamometer compared to a fixed isokinetic dynamometer to assess forearm torque strength
    Bonhof-Jansen, E. D. J.
    van Ham, A.
    Kroon, G. J.
    Winter, R. W.
    Brink, S. M.
    HAND SURGERY & REHABILITATION, 2023, 42 (02): : 147 - 153
  • [22] Reliability of isokinetic dynamometer for isometric assessment of ankle plantar flexor strength
    Santy, Fanny-May
    Pernoud, Anthony
    Barrue-Belou, Simon
    Fourchet, Francois
    Bothorel, Hugo
    Samozino, Pierre
    PHYSICAL THERAPY IN SPORT, 2025, 71 : 36 - 42
  • [23] Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity
    Martinez-Garcia, Dario
    Rodriguez-Perea, Angela
    Barboza, Paola
    Ulloa-Diaz, David
    Jerez-Mayorga, Daniel
    Chirosa, Ignacio
    Chirosa Rios, Luis Javier
    PEERJ, 2020, 8
  • [24] Reliability of trunk strength measurements with an isokinetic dynamometer in non-specific low back pain patients: A systematic review
    Reyes-Ferrada, Waleska
    Chirosa-Rios, Luis
    Martinez-Garcia, Dario
    Rodriguez-Perea, Angela
    Jerez-Mayorga, Daniel
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2022, 35 (05) : 937 - 948
  • [25] Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer
    Roth, Ralf
    Donath, Lars
    Kurz, Eduard
    Zahner, Lukas
    Faude, Oliver
    PHYSICAL THERAPY IN SPORT, 2017, 24 : 26 - 31
  • [26] Test-retest reproducibility of concentric strength values for shoulder girdle protraction and retraction using the Biodex isokinetic dynamometer
    Cools, AM
    Witvrouw, EE
    Danneels, LA
    Vanderstraeten, GG
    Cambier, DC
    ISOKINETICS AND EXERCISE SCIENCE, 2002, 10 (03) : 129 - 136
  • [27] A SIMPLE, INEXPENSIVE DEVICE CORRECTING GRAVITATIONAL EFFECTS IN ISOKINETIC MEASUREMENTS USING THE CYBEX-II DYNAMOMETER
    FILUSCH, EM
    GRAVENSTEIN, RO
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 247 - 247
  • [28] A SIMPLE, INEXPENSIVE DEVICE CORRECTING GRAVITATIONAL EFFECTS IN ISOKINETIC MEASUREMENTS USING THE CYBEX-II DYNAMOMETER
    FILUSCH, EM
    GRAVENSTEIN, RO
    PHYSICAL THERAPY, 1985, 65 (05): : 681 - 681
  • [29] RELIABILITY OF MUSCLE MECHANICAL CHARACTERISTICS FOR ISOKINETIC AND ISOTONIC SQUAT AND BENCH PRESS EXERCISE USING A MULTIFUNCTION COMPUTERIZED DYNAMOMETER
    HORTOBAGYI, T
    KATCH, FI
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1990, 61 (02) : 191 - 195
  • [30] Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer
    de Carvalho Froufe Andrade, Alberto Cesar Pereira
    Caserotti, Paolo
    Pereira de Carvalho, Carlos Manuel
    de Azevedo Abade, Eduardo Andre
    da Eira Sampaio, Antonio Jaime
    JOURNAL OF HUMAN KINETICS, 2013, 37 : 47 - 53