dynamometer;
linear isokinetic;
exercise;
intra-observer reliability;
intra-observer reproducibility;
muscle;
skeletal;
D O I:
暂无
中图分类号:
G8 [体育];
学科分类号:
04 ;
0403 ;
摘要:
Background. This study was performed to investigate the intraobserver reproducibility and reliability of measurements using a linear isokinetic dynamometer (Aristokin (R)). Methods. Sixteen female volunteers (age 18 to 23 years) participated in 4 test sessions, each consisting of 6 warming-up movements followed by 6 repetitions of 4 different movements. During each session, the subjects consecutively performed lifting movements by flexing elbows and shoulders (at 65 cm per see), total lifting movements with arms and legs (at 65 cm per see), and extension movements of the legs in sitting position (at 40 and 60 cm per see). The first 3 test sessions were performed at a weekly interval, the 4th was executed 4 weeks after the 3rd session. Force, power and explosivity (force developed per see) were recorded. Results. The intra-observer reproducibility was investigated of the 6 repetitions of the movements during each test session. The highest reproducibility for mean peak power and force was found in the combination of the 3rd, 4th, 5th and 6th measurement (intraclass correlation coefficient 0.85 to 0.99). Using this combination, the intra-observer reliability was investigated, defined as the consistency of results obtained during the 4 test sessions, performed at a weekly or longer interval. Comparison between these sessions showed that the results for mean force in the arm movement differed significantly (p=0.01) although a high between sessions correlation was found (0.96). Results for mean force and power for the 3 other movements were reliable, and no significant learning effect was observed. Lower reliability and reproducibility were observed for other parameters including explosivity and power and force at the first 0.25 see of the test movement. Conclusions. Even after standard warming-up movements, the first 2 out of 6 measurement repetitions during a test session are not reproducible and should not be used in calculations of the results. For the combination of the 3rd to 6th repetitions, a high reliability was found for the measurement of mean force and power of the total lifting movement and of the sitting leg extension movements repeated in 4 sessions over a period of 6 weeks.
机构:
Gen Hosp Murska Sobota, Dept Res & Educ, Murska Sobota, Slovenia
Univ Ljubljana, Fac Sport, Lab Sports & Med Diagnost, Ljubljana, SloveniaGen Hosp Murska Sobota, Dept Res & Educ, Murska Sobota, Slovenia
Kambic, Tim
Lainscak, Mitja
论文数: 0引用数: 0
h-index: 0
机构:
Gen Hosp Murska Sobota, Div Cardiol, Murska Sobota, Slovenia
Univ Ljubljana, Fac Med, Ljubljana, SloveniaGen Hosp Murska Sobota, Dept Res & Educ, Murska Sobota, Slovenia
机构:
Sports Medical Center Papendal, Papendallaan 7, Arnhem
Department of Rehabilitation, Physical Therapy Science and Sports, University Medical Center Utrecht, Utrecht
Research Group Musculoskeletal Rehabilitation, HAN University of Applied Sciences, NijmegenSports Medical Center Papendal, Papendallaan 7, Arnhem
Habets B.
Staal J.B.
论文数: 0引用数: 0
h-index: 0
机构:
Research Group Musculoskeletal Rehabilitation, HAN University of Applied Sciences, Nijmegen
Radboud University Medical Center, Research Institute for Health Sciences, IQ Healthcare, NijmegenSports Medical Center Papendal, Papendallaan 7, Arnhem
Staal J.B.
Tijssen M.
论文数: 0引用数: 0
h-index: 0
机构:
Sports Medical Center Papendal, Papendallaan 7, Arnhem
Radboud University Medical Center, Research Institute for Health Sciences, IQ Healthcare, NijmegenSports Medical Center Papendal, Papendallaan 7, Arnhem
Tijssen M.
Van Cingel R.
论文数: 0引用数: 0
h-index: 0
机构:
Sports Medical Center Papendal, Papendallaan 7, Arnhem
Radboud University Medical Center, Research Institute for Health Sciences, IQ Healthcare, NijmegenSports Medical Center Papendal, Papendallaan 7, Arnhem
机构:
Univ St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France
Univ Lyon, Exercise Physiol Lab, LPE EA 4338, St Etienne, FranceUniv St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France
Edouard, Pascal
Codine, Philippe
论文数: 0引用数: 0
h-index: 0
机构:
Clin La Pinede, St Esteve, France
Univ Hosp Montpellier, Dept Readaptat, Hop Lapeyronie, Montpellier, FranceUniv St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France
Codine, Philippe
Samozino, Pierre
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lyon, Exercise Physiol Lab, LPE EA 4338, St Etienne, France
Univ Savoie, Exercise Physiol Lab, EA4338, F-73376 Le Bourget Du Lac, FranceUniv St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France
Samozino, Pierre
Bernard, Pierre-Louis
论文数: 0引用数: 0
h-index: 0
机构:
Univ Montpellier I, Movement Hlth M2H, Fac Sport Sci, EA 2991, Montpellier, FranceUniv St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France
Bernard, Pierre-Louis
Herisson, Christian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hosp Montpellier, Dept Readaptat, Hop Lapeyronie, Montpellier, FranceUniv St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France
Herisson, Christian
Gremeaux, Vincent
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hosp Dijon, Dept Phys Med & Rehabil, Dijon, France
INSERM, Cognit Act & Plasticite Sensorimotrice U1093, Dijon, France
CHU Dijon, Ctr Invest Clin Plurithemat, INSERM 803, Dijon, FranceUniv St Etienne, Dept Phys Med & Rehabil, Univ Hosp St Etienne, Fac Med, St Etienne, France