Baumann Angle and Radial-Ulnar Overlap: A Radiographic Study to Control for the Angle of the X-Ray Beam

被引:12
作者
Pace, J. Lee [1 ]
Wiater, Brett [1 ]
Schmale, Gregory [1 ]
Jinguji, Thomas [1 ]
Bompadre, Viviana [1 ]
Krengel, Walter, III [1 ]
机构
[1] Univ Washington, Seattle Childrens Hosp, Dept Orthoped & Sports Med, Seattle, WA 98195 USA
关键词
Baumann angle; elbow; distal humerus; supracondylar humerus; SUPRACONDYLAR HUMERUS FRACTURES; CLOSED REDUCTION; CHILDREN;
D O I
10.1097/BPO.0b013e318259f2a1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Baumann's angle (BA) is the most common radiographic measurement used to assess coronal plane alignment of the distal humerus. However, it can vary greatly based on the x-ray beam angle, which can lead to multiple radiographs causing excessive radiation exposure, cost, and discomfort for the acutely injured child. The lateral capitellohumeral angle is a measure of sagittal plane alignment, and its variability has been reported. In this study, we sought to determine whether there were surrogate measures that could act as internal controls for the angle of the x-ray beam to give an accurate BA. Methods: Elbow radiographs from uninjured children stratified by age into 6 groups were reviewed. BA and lateral capitellohumeral angle as well as several predetermined measurements that could be potential surrogate measures for the angle of the x-ray beam were performed. Statistical significance was found between BA and radial-ulnar overlap (RUO), which was analyzed further and plotted in linear graph fashion. Results: The Pearson correlation coefficient (0.58) between BA and RUO was significant at P = 0.001. The average BA was 71 +/- 7.2 degrees (1 SD) and the average RUO was 0.34 +/- 0.26. The following linear graph equation was obtained to define the relationship between RUO and BA: BA = 12.36 (RUO) + 67. Further derivation gives us an equation to "correct" BA for a given RUO: corrected BA = measured BA - 12.36 (RUO - 0.34). Application of this formula lessened the SD of BA from 7.2 to 5.9 degrees and decreased the percentage of BA measurements outside of 1 SD from 30% to 14%. Conclusions: RUO is a reliable surrogate measure to control for the angle of the x-ray beam and improve the reliability when measuring BA that can be easily applied in the clinical setting.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 16 条
  • [1] Baumann's confusing legacy
    Acton, JD
    McNally, MA
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 (01): : 41 - 43
  • [2] ARONSON DD, 1987, CLIN ORTHOP RELAT R, P174
  • [3] ALTERATION OF BAUMANN ANGLE BY HUMERAL POSITION - IMPLICATIONS FOR TREATMENT OF SUPRACONDYLAR HUMERUS FRACTURES
    CAMP, J
    ISHIZUE, K
    GOMEZ, M
    GELBERMAN, R
    AKESON, W
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1993, 13 (04) : 521 - 525
  • [4] DEFORMITY AND FUNCTION IN SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN VARIOUSLY TREATED BY CLOSED REDUCTION AND SPLINTING, TRACTION, AND PERCUTANEOUS PINNING
    FRANCE, J
    STRONG, M
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1992, 12 (04) : 494 - 498
  • [5] GREEN NE, 2003, SKELETAL TRAUMA CHIL, P257
  • [6] Greenspan A, 2004, ORTHOPEDIC IMAGING P, P135
  • [7] Variation of Baumann's angle with age, sex, and side: Implications for its use in radiological monitoring of supracondylar fracture of the humerus in children
    Keenan, WNW
    Clegg, J
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1996, 16 (01) : 97 - 98
  • [8] Liyang D, 1999, J PEDIAT ORTHOP B, V8, P197
  • [9] Systematic pinning of displaced extension-type supracondylar fractures of the humerus in children
    Mazda, K
    Boggione, C
    Fitoussi, F
    Penneçot, GF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06): : 888 - 893
  • [10] The Baumann angle in supracondylar fractures of the distal humerus in children
    Mohammad, S
    Rymaszewski, LA
    Runciman, J
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1999, 19 (01) : 65 - 69