Quasi-static cyclic tests of precast bridge columns with different connection details for high seismic zones

被引:120
作者
Wang, Zhiqiang [1 ]
Qu, Hongya [2 ]
Li, Tiantian [2 ]
Wei, Hongyi [1 ]
Wang, Hao [1 ]
Duan, Hongliang [1 ]
Jiang, Haixi [3 ]
机构
[1] Tongji Univ, Dept Bridge Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Missouri Univ Sci & Technol, Dept Civil Architectural & Environm Engn, 326 Butler Carlton Hall,1401 N Pine St, Rolla, MO 65409 USA
[3] Shanghai SMI Highway Grp Co Ltd, 99 Hami Rd, Shanghai 200335, Peoples R China
基金
美国国家科学基金会;
关键词
Bridge column; Cyclic loading; Finite element method; Grouted connection; Precast concrete; Prestressing steel; Segmental construction; Seismic performance; REINFORCING BARS; BOND STRENGTH; STEEL;
D O I
10.1016/j.engstruct.2017.12.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, seven 1/3-scale bridge column specimens are investigated under the same quasi-static cyclic loading protocol both experimentally and numerically. The specimens consist of one cast-in-place (CIP) reference column and six precast columns. The precast columns are designed with different connection details, and they are tested for the feasibility study of the urban viaducts of highway S6 in Shanghai, China. The seismic performance of the precast columns needs to be investigated and verified prior to the practical application of these connection designs. Based on the experimental results, the precast specimens solely using mild reinforcement exhibit similar hysteretic behavior to the CIP reference column, though various grouted connection approaches are employed. The differences between these precast specimens and the CIP reference column are less than 15% for all indices. The precast specimens with bonded tendons (prestressing strands or prestressing bars) retain higher strength, but no less than 30% decrease of energy dissipation capacity is found. The bonded prestressing strands give at least 10% increase in strength compared with the CIP reference column, while the bonded prestressing bars provide approximately 50% improvement. The precast specimen utilizing unbonded tendon (prestressing strands) shows unique self-centering capability with equivalent energy dissipation capacity of the CIP reference column, but it has 33% lower ductility. Finite element modeling is performed and calibrated with the test data. Bond-slip behavior near column-to-footing interface is modeled by using a ZeroLength element at the interface. Buckling, fatigue and strength reduction of reinforcement are also considered in the model. Hysteretic behaviors of the specimens can be effectively simulated, and differences of ultimate strengths between the experimental and numerical results are less than 9%.
引用
收藏
页码:13 / 27
页数:15
相关论文
共 36 条
[1]   A simplified analysis method for characterizing unbonded post-tensioned precast wall systems [J].
Aaleti, Sriram ;
Sritharan, Sri .
ENGINEERING STRUCTURES, 2009, 31 (12) :2966-2975
[2]  
Ameli M., 2016, J STRUCT ENG, V143
[3]  
[Anonymous], 2007, PRECAST SEGMENTAL PO
[4]  
Arai T, 2000, KATRI ANN REP, V48, P25
[5]   Cyclic Response of Unbonded Posttensioned Precast Columns with Ductile Fiber-Reinforced Concrete [J].
Billington, S. L. ;
Yoon, J. K. .
JOURNAL OF BRIDGE ENGINEERING, 2004, 9 (04) :353-363
[6]   A precast segmental substructure system for standard bridges [J].
Billington, SL ;
Barnes, RW ;
Breen, JE .
PCI JOURNAL, 1999, 44 (04) :56-+
[7]   Numerical simulation of hollow steel profiles for lightweight concrete sandwich panels [J].
Brunesi, E. ;
Nascimbene, R. ;
Deyanova, M. ;
Pagani, C. ;
Zambelli, S. .
COMPUTERS AND CONCRETE, 2015, 15 (06) :951-972
[8]   Hysteretic Modeling of Unbonded Posttensioned Precast Segmental Bridge Columns with Circular Section Based on Cyclic Loading Test [J].
Bu, Zhan-Yu ;
Ou, Yu-Chen ;
Song, Jian-Wei ;
Lee, George C. .
JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (06)
[9]  
Caltrans S.D. C., 2013, CALTRANS SEISMIC DES
[10]  
Chang K., 2002, SEISMIC BEHAV PRECAS