Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation

被引:9
|
作者
Fleischhauer, Vincent [1 ,2 ]
Feldheiser, Aarne [3 ,4 ,5 ,6 ,7 ]
Zaunseder, Sebastian [1 ,2 ]
机构
[1] Univ Appl Sci & Arts Dortmund, Fac Informat Technol, D-44139 Dortmund, Germany
[2] Tech Univ Dresden, Inst Biomed Engn, D-01069 Dresden, Germany
[3] Evang Kliniken Essen Mitte, Huyssens Stiftung Knappschaft, Dept Anaesthesiol Intens Care Med & Pain Therapy, D-45136 Essen, Germany
[4] Charite Univ Med Berlin, Dept Anaesthesiol & Operat Intens Care Med CCM, CVK, D-13353 Berlin, Germany
[5] Free Univ Berlin, D-13353 Berlin, Germany
[6] Humboldt Univ, D-13353 Berlin, Germany
[7] Berlin Inst Hlth, D-13353 Berlin, Germany
关键词
blood pressure; pulse wave decomposition; pulse decomposition analysis; photoplethysmography; Shapley values; estimation; interpretation; explainability; PULSE TRANSIT-TIME; SIGNAL; MODEL;
D O I
10.3390/s22187037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is among the most important vital signals. Estimation of absolute BP solely using photoplethysmography (PPG) has gained immense attention over the last years. Available works differ in terms of used features as well as classifiers and bear large differences in their results. This work aims to provide a machine learning method for absolute BP estimation, its interpretation using computational methods and its critical appraisal in face of the current literature. We used data from three different sources including 273 subjects and 259,986 single beats. We extracted multiple features from PPG signals and its derivatives. BP was estimated by xgboost regression. For interpretation we used Shapley additive values (SHAP). Absolute systolic BP estimation using a strict separation of subjects yielded a mean absolute error of 9.456mmHg and correlation of 0.730. The results markedly improve if data separation is changed (MAE: 6.366mmHg, r: 0.874). Interpretation by means of SHAP revealed four features from PPG, its derivation and its decomposition to be most relevant. The presented approach depicts a general way to interpret multivariate prediction algorithms and reveals certain features to be valuable for absolute BP estimation. Our work underlines the considerable impact of data selection and of training/testing separation, which must be considered in detail when algorithms are to be compared. In order to make our work traceable, we have made all methods available to the public.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Beat-to-beat ambulatory blood pressure estimation based on random forest
    He, Rui
    Huang, Zhi-Pei
    Ji, Lian-Ying
    Wu, Jian-Kang
    Li, Huihui
    Zhang, Zhi-Qiang
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 194 - 198
  • [2] Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals
    Wuerich, Carolin
    Wiede, Christian
    Schiele, Gregor
    2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS, 2023, : 305 - 310
  • [3] A Probabilistic Beat-to-Beat Filtering Model for Continuous and Accurate Blood Pressure Estimation
    Chen, Zehua
    Dees, Bruno Scalzo
    Mandic, Danilo P.
    2020 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2020,
  • [4] Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification
    Farzam, Ramin
    Azad, Mohammad Hasan
    Moghaddam, Hamid Abrishami
    Forouzanfar, Mohamad
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (02) : 619 - 629
  • [5] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [6] Baroreflex failure and beat-to-beat blood pressure variation
    Kishi, Takuya
    HYPERTENSION RESEARCH, 2018, 41 (08) : 547 - 552
  • [7] Baroreflex failure and beat-to-beat blood pressure variation
    Takuya Kishi
    Hypertension Research, 2018, 41 : 547 - 552
  • [8] Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring
    Kim, Joshua
    Chou, En-Fan
    Le, Jamie
    Wong, Sabrina
    Chu, Michael
    Khine, Michelle
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
  • [9] Beat-to-Beat Blood Pressure Variability and Cognition in the MIDUS Study
    Sweigert, Joshua
    McKinley, Paula
    Lachman, Margie
    Gruenewald, Tara
    Seeman, Teresa
    Love, Gayle
    Weinstein, Maxine
    McIntyre, Kathleen
    Duong, Jimmy
    Sloan, Richard P.
    PSYCHOSOMATIC MEDICINE, 2017, 79 (04): : A154 - A155
  • [10] Reliability of beat-to-beat blood pressure variability in older adults
    Lohman, Trevor
    Sible, Isabel J.
    Shenasa, Fatemah
    Engstrom, Allison C.
    Kapoor, Arunima
    Alitin, John Paul M.
    Gaubert, Aimee
    Thayer, Julian F.
    Ferrer, Farrah
    Nation, Daniel A.
    SCIENTIFIC REPORTS, 2024, 14 (01):