Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

被引:7
|
作者
Shinohara, Takaaki [1 ]
Hirata, Hitoshi [2 ]
机构
[1] Chunichi Hosp, Nagoya Hand Surg Ctr, Nagoya, Aichi, Japan
[2] Nagoya Univ, Dept Hand Surg, Grad Sch Med, Nagoya, Aichi, Japan
来源
NAGOYA JOURNAL OF MEDICAL SCIENCE | 2017年 / 79卷 / 04期
关键词
Distal radius fracture; non-union; ulnar variance; unaffected wrist; volar locking plate; COMPLICATIONS;
D O I
10.18999/nagjms.79.4.551
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus variance. Radiographs of the unaffected wrist showed 3.5-mm ulnar plus variance. Intraoperative findings of surgical revision showed an unstable nonunion; thus, debridement of the nonunion, autogenous inlay bone grafting, and internal fixation using another type of volar locking plate system were performed. Healing of the re-operative site was confirmed radiographically 3 months postoperatively. We considered that volar locking plate fixation with excessive distraction of the fracture may lead to nonunion.
引用
收藏
页码:551 / 557
页数:7
相关论文
共 50 条
  • [31] Multiple ruptures of the extensor tendons after volar fixation for distal radius fracture: a case report
    Caruso, Giancarlo
    Vitali, Andrea
    del Prete, Ferdinando
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S23 - S27
  • [32] Volar locking plate removal after distal radius fracture: a 10-year retrospective study
    Lee, Jun-Ku
    Lee, Younghun
    Kim, Choongki
    Kim, Minwook
    Han, Soo-Hong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (10) : 1711 - 1719
  • [33] Incidence for volar locking plate removal following distal radius fracture surgery
    Vili Palola
    Ville Ponkilainen
    Tuomas Huttunen
    Antti Launonen
    Ville M. Mattila
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1297 - 1302
  • [34] Results of internal fixation for unstable distal radius fracture with palmar locking plate
    Windolf, J.
    Hakimi, M.
    Schaedel-Hoepfner, M.
    TRAUMA UND BERUFSKRANKHEIT, 2008, 10 : 236 - 240
  • [35] Cause of Extensor Pollicis Longus Ruptures After Distal Radius Fracture Fixation Using a Volar Plate
    Laane, Charlotte L. E.
    Dijkmans, Anjuli L.
    Messinger, Chelsea J.
    Wijffels, Mathieu M. E.
    Bhashyam, Abhiram R.
    Chen, Neal C.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [36] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [37] Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures with Volar Lunate Facet Fragments Distal to the Watershed Line
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (01) : 24 - 31
  • [38] Risk Factors Associated with Collapse of Distal Radius Fractures after Volar Locking Plate Fixation in Older Adults
    Lee, Sanglim
    Jeon, Suk Ha
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2025,
  • [39] Incidence of Hardware Removal Following Volar Plate Fixation of Distal Radius Fracture
    Lutsky, Kevin F.
    Beredjiklian, Pedro K.
    Hioe, Stephen
    Bilello, Justin
    Kim, Nayoung
    Matzon, Jonas L.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (12): : 2410 - 2415
  • [40] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509