Mapping Contact Force during Catheter Ablation for the Treatment of Atrial Fibrillation: New Insights into Ablation Therapy

被引:0
作者
Karim, Rashed [1 ]
Gao, Gang [1 ]
Harrison, James [1 ]
Arujuna, Aruna [1 ]
Lambert, Hendrik [3 ]
Leo, Giovanni [3 ]
Gill, Jaswinder [2 ]
Razavi, Reza [1 ]
Schaeffter, Tobias [1 ]
O'Neill, Mark [2 ]
Rhode, Kawal S. [1 ]
机构
[1] Kings Coll London, Div Imaging Sci, London SE1 7EH, England
[2] St Thomas Hosp, Dept Cardiol, London SE1 7EH, England
[3] Endosense SA, Geneva, Switzerland
来源
FUNCTIONAL IMAGING AND MODELING OF THE HEART | 2011年 / 6666卷
关键词
catheter ablation; atrial fibrillation; contact force; visualization techniques; image-guided intervention;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The distribution of ablation catheter contact force may be important for elucidating the mechanisms of pulmonary vein (PV) reconnection following PV isolation (PVI) for the treatment of paroxysmal atrial fibrillation (PAF). A novel method was developed for the visualisation of tissue contact force on left atrial models derived from segmented MRI data and the approach was tested in 3 patients. The left atrium was automatically segmented from preprocedural whole-heart cardiac magnetic resonance (CMR) scans in three patients undergoing circumferential PVI for catheter ablation of PAF. During the procedure, the CMR shell was overlaid on to real-time fluoroscopy using the EP Navigator (EPN) software (Philips Healthcare, The Netherlands) and registered using the trachea and intracardiac catheters. Using a wide area circumferential approach to encircle ipsilateral pairs of PVs, the position of each radiofrequency (RF) application (25W for 40s) was recorded on the CMR shell using the point tagging feature of EPN. Using a contact force-sensing ablation catheter (TactiCath, Endosense, Switzerland), the contact force-time integral (FTI) for each registered ablation point was recorded. The FTI for each point was then projected on to the CMR shell with a circular diameter of 10mm using custom-made software. This radius of force distribution was chosen to reflect the typical accuracy of location of the mapping catheter and also to take into account the motion of the catheter during the RF application. 4 vein PVI and FTI maps were achieved in all patients (see figure 1 for example). The mean FTI applied to each side of the left atrium was recorded in gram seconds. The total and regional FTIs applied Fig. 1. The FTI map for each patient in three separate views (from left to right: posterior, right PVs and anterior to achieve PVI differed between and within patients respectively, but in an inconsistent manner. The FTI map on the pre-segmented atrial shell provides an intuitive post-procedural assessment of the tissue-contact force achieved during RF delivery. The FTI is less consistent between patients for the RPVs than for the LPVs, perhaps reflecting patient-specific technical challenges. Comparison of FTI maps with post-ablation delayed enhancement, T2W MRI and clinical outcome data may assist in understanding the mechanisms of effective lesion delivery and of PV reconnection after ablation.
引用
收藏
页码:302 / +
页数:2
相关论文
共 50 条
  • [31] Optimizing contact force during ablation of atrial fibrillation: available technologies and a look to the future
    de Vries, Lennart J.
    Szili-Torok, Tamas
    FUTURE CARDIOLOGY, 2016, 12 (02) : 197 - 207
  • [32] Atrial fibrillation: Catheter ablation
    Chugh, Aman
    Morady, Fred
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (01) : 15 - 26
  • [33] Catheter Ablation of Atrial Fibrillation
    Latchamsetty, Rakesh
    Morady, Fred
    HEART FAILURE CLINICS, 2016, 12 (02) : 223 - +
  • [34] Catheter Ablation for Atrial Fibrillation
    Thomas, Stuart P.
    Sanders, Prashanthan
    HEART LUNG AND CIRCULATION, 2012, 21 (6-7) : 395 - 401
  • [35] Atrial fibrillation: Catheter ablation
    Aman Chugh
    Fred Morady
    Journal of Interventional Cardiac Electrophysiology, 2006, 16 : 15 - 26
  • [36] Catheter ablation of atrial fibrillation
    Ng, FS
    Camm, AJ
    CLINICAL CARDIOLOGY, 2002, 25 (08) : 384 - 394
  • [37] Catheter Ablation of Atrial Fibrillation
    Callahan, Thomas D.
    Di Biase, Luigi
    Horton, Rodney
    Sanchez, Javier
    Gallinghouse, Joseph G.
    Natale, Andrea
    CARDIOLOGY CLINICS, 2009, 27 (01) : 163 - +
  • [38] Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study
    Reddy, Vivek Y.
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Natale, Andrea
    Albenque, Jean-Paul
    Kautzner, Josef
    Shah, Dipen
    Michaud, Gregory
    Wharton, Marcus
    Harari, David
    Mahapatra, Srijoy
    Lambert, Hendrik
    Mansour, Moussa
    CIRCULATION, 2015, 132 (10) : 907 - 915
  • [39] Catheter Ablation of Atrial Fibrillation
    Ching, Chi Keong
    Patel, Dimpi
    Natale, Andrea
    JOURNAL OF ARRHYTHMIA, 2007, 23 (02) : 85 - 101
  • [40] Safety of catheter ablation of atrial fibrillation using fiber optic-based contact force sensing
    Mansour, Moussa
    Lakkireddy, Dhanunjaya
    Packer, Douglas
    Day, John D.
    Mahapatra, Srijoy
    Brunner, Kyle
    Reddy, Vivek
    Natale, Andrea
    HEART RHYTHM, 2017, 14 (11) : 1631 - 1636