Mapping Contact Force during Catheter Ablation for the Treatment of Atrial Fibrillation: New Insights into Ablation Therapy

被引:0
|
作者
Karim, Rashed [1 ]
Gao, Gang [1 ]
Harrison, James [1 ]
Arujuna, Aruna [1 ]
Lambert, Hendrik [3 ]
Leo, Giovanni [3 ]
Gill, Jaswinder [2 ]
Razavi, Reza [1 ]
Schaeffter, Tobias [1 ]
O'Neill, Mark [2 ]
Rhode, Kawal S. [1 ]
机构
[1] Kings Coll London, Div Imaging Sci, London SE1 7EH, England
[2] St Thomas Hosp, Dept Cardiol, London SE1 7EH, England
[3] Endosense SA, Geneva, Switzerland
来源
FUNCTIONAL IMAGING AND MODELING OF THE HEART | 2011年 / 6666卷
关键词
catheter ablation; atrial fibrillation; contact force; visualization techniques; image-guided intervention;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The distribution of ablation catheter contact force may be important for elucidating the mechanisms of pulmonary vein (PV) reconnection following PV isolation (PVI) for the treatment of paroxysmal atrial fibrillation (PAF). A novel method was developed for the visualisation of tissue contact force on left atrial models derived from segmented MRI data and the approach was tested in 3 patients. The left atrium was automatically segmented from preprocedural whole-heart cardiac magnetic resonance (CMR) scans in three patients undergoing circumferential PVI for catheter ablation of PAF. During the procedure, the CMR shell was overlaid on to real-time fluoroscopy using the EP Navigator (EPN) software (Philips Healthcare, The Netherlands) and registered using the trachea and intracardiac catheters. Using a wide area circumferential approach to encircle ipsilateral pairs of PVs, the position of each radiofrequency (RF) application (25W for 40s) was recorded on the CMR shell using the point tagging feature of EPN. Using a contact force-sensing ablation catheter (TactiCath, Endosense, Switzerland), the contact force-time integral (FTI) for each registered ablation point was recorded. The FTI for each point was then projected on to the CMR shell with a circular diameter of 10mm using custom-made software. This radius of force distribution was chosen to reflect the typical accuracy of location of the mapping catheter and also to take into account the motion of the catheter during the RF application. 4 vein PVI and FTI maps were achieved in all patients (see figure 1 for example). The mean FTI applied to each side of the left atrium was recorded in gram seconds. The total and regional FTIs applied Fig. 1. The FTI map for each patient in three separate views (from left to right: posterior, right PVs and anterior to achieve PVI differed between and within patients respectively, but in an inconsistent manner. The FTI map on the pre-segmented atrial shell provides an intuitive post-procedural assessment of the tissue-contact force achieved during RF delivery. The FTI is less consistent between patients for the RPVs than for the LPVs, perhaps reflecting patient-specific technical challenges. Comparison of FTI maps with post-ablation delayed enhancement, T2W MRI and clinical outcome data may assist in understanding the mechanisms of effective lesion delivery and of PV reconnection after ablation.
引用
收藏
页码:302 / +
页数:2
相关论文
共 50 条
  • [1] Atrial fibrillation: insights on mechanisms, mapping and catheter ablation
    Conti, Sergio
    Verma, Atul
    Natale, Andrea
    Tondo, Claudio
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [2] The impact of steerable sheaths on unblinded contact force during catheter ablation for atrial fibrillation
    Deyell, Marc W.
    Wen, Glen
    Laksman, Zachary
    Bennett, Matthew T.
    Chakrabarti, Santabhanu
    Yeung-Lai-Wah, John A.
    Krahn, Andrew D.
    Andrade, Jason G.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (03) : 417 - 424
  • [3] The impact of steerable sheaths on unblinded contact force during catheter ablation for atrial fibrillation
    Marc W. Deyell
    Glen Wen
    Zachary Laksman
    Matthew T. Bennett
    Santabhanu Chakrabarti
    John A. Yeung-Lai-Wah
    Andrew D. Krahn
    Jason G. Andrade
    Journal of Interventional Cardiac Electrophysiology, 2020, 57 : 417 - 424
  • [4] The symbiosis of contact force catheter use for hybrid ablation for atrial fibrillation
    Kumar, N.
    Pison, L.
    Lozekoot, P.
    Choudhury, R.
    La Meir, M.
    Gelsomino, S.
    Crijns, H.
    Maessen, J.
    NETHERLANDS HEART JOURNAL, 2015, 23 (09) : 438 - 444
  • [5] The symbiosis of contact force catheter use for hybrid ablation for atrial fibrillation
    N. Kumar
    L. Pison
    P. Lozekoot
    R. Choudhury
    M. La Meir
    S. Gelsomino
    H. Crijns
    J. Maessen
    Netherlands Heart Journal, 2015, 23 : 438 - 446
  • [6] Real-world safety of catheter ablation for atrial fibrillation with contact force or cryoballoon ablation
    Natale, Andrea
    Mohanty, Sanghamitra
    Goldstein, Laura
    Gomez, Tara
    Hunter, Tina D.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (03) : 445 - 452
  • [7] Real-world safety of catheter ablation for atrial fibrillation with contact force or cryoballoon ablation
    Andrea Natale
    Sanghamitra Mohanty
    Laura Goldstein
    Tara Gomez
    Tina D. Hunter
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 445 - 452
  • [8] Atrial rhythm influences catheter tissue contact during radiofrequency catheter ablation of atrial fibrillation: comparison of contact force between sinus rhythm and atrial fibrillation
    Hisao Matsuda
    Abdul Shokor Parwani
    Philipp Attanasio
    Martin Huemer
    Alexander Wutzler
    Florian Blaschke
    Wilhelm Haverkamp
    Leif-Hendrik Boldt
    Heart and Vessels, 2016, 31 : 1544 - 1552
  • [9] Combined contact force and local impedance dynamics during repeat atrial fibrillation catheter ablation
    Alken, Fares-Alexander
    Scherschel, Katharina
    Kahle, Ann-Kathrin
    Masjedi, Mustafa
    Meyer, Christian
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [10] Atrial rhythm influences catheter tissue contact during radiofrequency catheter ablation of atrial fibrillation: comparison of contact force between sinus rhythm and atrial fibrillation
    Matsuda, Hisao
    Parwani, Abdul Shokor
    Attanasio, Philipp
    Huemer, Martin
    Wutzler, Alexander
    Blaschke, Florian
    Haverkamp, Wilhelm
    Boldt, Leif-Hendrik
    HEART AND VESSELS, 2016, 31 (09) : 1544 - 1552