Nitrate-selective optical sensor applying a lipophilic fluorescent potential-sensitive dye

被引:34
|
作者
Huber, C
Klimant, I
Krause, C
Werner, T
Wolfbeis, OS [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
[2] Graz Univ Technol, Inst Analyt Chem, A-8010 Graz, Austria
关键词
emulsion sensor; nitrate sensor; potential-sensitive dye; dual lifetime referencing; reference beads;
D O I
10.1016/S0003-2670(01)01363-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optical sensor has been developed for continuous determination of nitrate that is based on a polymer-stabilized emulsion system consisting of a hydrogel with entrapped plasticizer droplets. The droplets contain a cationic potential-sensitive fluorescent dye (PSD) located near its surface. The cationic PSD also acts as an anion-exchange catalyst that extracts nitrate out of the aqueous solution to form a complex (PSD+/NO3-) that moves into the plasticizer droplet due to its lipophilicity. This process causes a decrease of micro-polarity near the dye, resulting in an increase in the fluorescence intensity of the PSD. In a second detection scheme, the fluorescence intensity information of the PSD is converted into a fluorescence phase shift by mixing into the membrane particles that contain an inert long-lifetime reference luminophore. The second sensing scheme is referred to as "dual lifetime referencing". Both schemes can be used for reversible sensing of nitrate in the 0.1-50 mM range, with response times in the order of 3 min. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 93
页数:13
相关论文
共 50 条
  • [21] Development of a sensitive nitrate-selective electrode for on-site use in fresh waters
    Sutton, PG
    Braven, J
    Ebdon, L
    Scholefield, D
    ANALYST, 1999, 124 (06) : 877 - 882
  • [22] MYCOPLASMA MEMBRANE-POTENTIALS DETERMINED BY POTENTIAL-SENSITIVE FLUORESCENT DYES
    SCHUMMER, U
    SCHIEFER, HG
    GERHARDT, U
    CURRENT MICROBIOLOGY, 1979, 2 (03) : 191 - 194
  • [23] Development of micro-fluidic nitrate-selective sensor based on polypyrrole nanowires
    Aravamudhan, Shyam
    Bhansali, Shekhar
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [24] A membrane potential-sensitive dye for vascular smooth muscle cells assays
    Sguilla, FS
    Tedesco, AC
    Bendhack, LM
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 301 (01) : 113 - 118
  • [25] Real-time and high throughput monitoring of cAMP in live cells using a fluorescent membrane potential-sensitive dye
    Tang, Yi
    Li, Xiuqing
    He, Jianjun
    Lu, Junge
    Diwu, Zhenjun
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2006, 4 (04) : 461 - 471
  • [26] POTENTIAL-SENSITIVE FLUORESCENT DYES IN ELECTROCHEMISTRY OF LIQUID-LIQUID INTERFACES
    VANYSEK, P
    WIEGAND, DH
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (03) : C134 - C134
  • [27] USE OF AN AGED NITRATE-SELECTIVE ELECTRODE AS HALIDE-SENSOR IN POTENTIOMETRIC TITRATIONS
    BARRADO, E
    PARDO, R
    REVUE ROUMAINE DE CHIMIE, 1984, 29 (08) : 693 - 698
  • [28] CELL AGE-RELATED DIFFERENCES IN THE INTERACTION OF A POTENTIAL-SENSITIVE FLUORESCENT DYE WITH NUCLEAR ENVELOPES OF ACETABULARIA-MEDITERRANEA
    MATZKE, MA
    MATZKE, AJM
    NEUHAUS, G
    PLANT CELL AND ENVIRONMENT, 1988, 11 (03): : 157 - 163
  • [29] Application of potential-sensitive fluorescent dyes in anion- and cation-sensitive polymer membranes
    Mohr, GJ
    Murkovic, I
    Lehmann, F
    Haider, C
    Wolfbeis, OS
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) : 239 - 245
  • [30] Application of potential-sensitive fluorescent dyes in anion- and cation-sensitive polymer membranes
    Mohr, G.J.
    Murkovic, I.
    Lehmann, F.
    Haider, C.
    Wolfbeis, O.S.
    Sensors and Actuators, B: Chemical, 1997, B39 (1 -3 pt 2): : 239 - 245