Design, development and evaluation of a compact telerobotic catheter navigation system

被引:32
作者
Tavallaei, Mohammad Ali [1 ,2 ]
Gelman, Daniel [1 ,2 ]
Lavdas, Michael Konstantine [1 ,3 ]
Skanes, Allan C. [4 ]
Jones, Douglas L. [1 ,5 ,6 ]
Bax, Jeffrey S. [7 ]
Drangova, Maria [1 ,2 ,8 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, Robarts Res Inst, London, ON, Canada
[2] Univ Western Ontario, Biomed Engn Grad Programme, London, ON, Canada
[3] Univ Western Ontario, Mechatron Engn Programme, London, ON, Canada
[4] Univ Western Ontario, Schulich Sch Med & Dent, Dept Med, London, ON, Canada
[5] Univ Hosp, London Hlth Sci Ctr, Canadian Surg Technol & Adv Robot, London, ON, Canada
[6] Univ Western Ontario, Schulich Sch Med & Dent, Dept Physiol & Pharmacol, London, ON, Canada
[7] Ctr Imaging Technol Commercializat CIMTEC, London, ON, Canada
[8] Univ Western Ontario, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
基金
加拿大健康研究院;
关键词
catheterization; image-guided intervention; master-slave; telerobotics; medical robotics; REMOTE-CONTROL SYSTEM; EXPERIENCE; SAFETY; ROBOT; CARDIOLOGISTS; EXPOSURE; ABLATION; GUIDANCE; DEVICES; TRIAL;
D O I
10.1002/rcs.1711
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Remote catheter navigation systems protect interventionalists from scattered ionizing radiation. However, these systems typically require specialized catheters and extensive operator training. Methods A new compact and sterilizable telerobotic system is described, which allows remote navigation of conventional tip-steerable catheters, with three degrees of freedom, using an interface that takes advantage of the interventionalist's existing dexterity skills. The performance of the system is evaluated ex vivo and in vivo for remote catheter navigation and ablation delivery. Results The system has absolute errors of 0.1 +/- 0.1mm and 7 +/- 6 degrees over 100mm of axial motion and 360 degrees of catheter rotation, respectively. In vivo experiments proved the safety of the proposed telerobotic system and demonstrated the feasibility of remote navigation and delivery of ablation. Conclusion The proposed telerobotic system allows the interventionalist to use conventional steerable catheters; while maintaining a safe distance from the radiation source, he/she can remotely navigate the catheter and deliver ablation lesions. Copyright (C) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:442 / 452
页数:11
相关论文
共 50 条
  • [31] High Precise Haptic Device for the Robotic Catheter Navigation System
    Guo, Shuxiang
    Qin, Mingyang
    Xiao, Nan
    Wang, Yuan
    Peng, Weili
    Bao, Xianqiang
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 2524 - 2529
  • [32] Design of Navigation System for Liver Surgery Guided by Augmented Reality
    Zhang, Fengfeng
    Zhang, Shi
    Zhong, Kai
    Yu, Lingtao
    Sun, Li Ning
    [J]. IEEE ACCESS, 2020, 8 : 126687 - 126699
  • [33] A device for real-time measurement of catheter-motion and input to a catheter navigation system
    Thakur, Yogesh
    Cakiroglu, Jason H.
    Holdsworth, David W.
    Drangova, Maria
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [34] Surgical navigation system design for MISS
    Chen, Yanqiu
    Qiu, Jianhua
    Song, Yinhao
    [J]. ICCSSE 2009: PROCEEDINGS OF 2009 4TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE & EDUCATION, 2009, : 1170 - +
  • [35] Robot-assisted ultrasound imaging: Overview and development of a parallel telerobotic system
    Monfaredi, Reza
    Wilson, Emmanuel
    Koutenaei, Bamshad Azizi
    Labrecque, Brendan
    Leroy, Kristen
    Goldie, James
    Louis, Eric
    Swerdlow, Daniel
    Cleary, Kevin
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2015, 24 (01) : 54 - 62
  • [36] Development of a Force-Reflecting Robotic Platform for Cardiac Catheter Navigation
    Park, Jun Woo
    Choi, Jaesoon
    Pak, Hui-Nam
    Song, Seung Joon
    Lee, Jung Chan
    Park, Yongdoo
    Shin, Seung Min
    Sun, Kyung
    [J]. ARTIFICIAL ORGANS, 2010, 34 (11) : 1034 - 1039
  • [37] Design and experimental evaluation of a teleoperated haptic robot-assisted catheter operating system
    Yin, Xuanchun
    Guo, Shuxiang
    Hirata, Hideyuki
    Ishihara, Hidenori
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2016, 27 (01) : 3 - 16
  • [38] Design and Evaluation of a Novel Guidewire Navigation Robot
    Bao, Xianqiang
    Guo, Shuxiang
    Xiao, Nan
    Wang, Yuan
    Qin, Mingyang
    Zhao, Yan
    Xu, Changqi
    Peng, Weili
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 431 - 436
  • [39] An Impedance-Based Catheter Positioning System for Cardiac Mapping and Navigation
    Jiang, Yuan
    Farina, Dima
    Bar-Tal, Meir
    Doessel, Olaf
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (08) : 1963 - 1970
  • [40] Multi-turn, Tension-stiffening Catheter Navigation System
    Chen, Yi
    Chang, Jean H.
    Greenlee, Alison S.
    Cheung, Kenneth C.
    Slocum, Alex H.
    Gupta, Rajiv
    [J]. 2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, : 5570 - 5575