Multi-Rigid Image Segmentation and Registration for the Analysis of Joint Motion From Three-Dimensional Magnetic Resonance Imaging

被引:12
作者
Hu, Yangqiu [1 ,2 ]
Ledoux, William R. [3 ,4 ,5 ]
Fassbind, Michael [3 ]
Rohr, Eric S. [3 ]
Sangeorzan, Bruce J. [3 ,5 ]
Haynor, David [1 ,2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[3] VA Ctr Excellence Limb Loss Prevent & Prosthet En, Seattle, WA 98108 USA
[4] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[5] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 10期
关键词
joint motion; MRI; segmentation; registration; visualization; ANKLE; SUBTALAR; KINEMATICS; FOOT; MR;
D O I
10.1115/1.4005175
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an image segmentation and registration method for studying joint morphology and kinematics from in vivo magnetic resonance imaging (MRI) scans and its application to the analysis of foot and ankle joint motion. Using an MRI-compatible positioning device, a foot was scanned in a single neutral and seven other positions ranging from maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation. A segmentation method combining graph cuts and level set was developed. In the subsequent registration step, a separate rigid body transformation for each bone was obtained by registering the neutral position dataset to each of the other ones, which produced an accurate description of the motion between them. The segmentation algorithm allowed a user to interactively delineate 14 foot bones in the neutral position volume in less than 30 min total (user and computer processing unit [CPU]) time. Registration to the seven other positions took approximately 10 additional minutes of user time and 5.25 h of CPU time. For validation, our results were compared with those obtained from 3DViewnix, a semiautomatic segmentation program. We achieved excellent agreement, with volume overlap ratios greater than 88% for all bones excluding the intermediate cuneiform and the lesser metatarsals. For the registration of the neutral scan to the seven other positions, the average overlap ratio is 94.25%, while the minimum overlap ratio is 89.49% for the tibia between the neutral position and position 1, which might be due to different fields of view (FOV). To process a single foot in eight positions, our tool requires only minimal user interaction time (less than 30 min total), a level of improvement that has the potential to make joint motion analysis from MRI practical in research and clinical applications. [DOI: 10.1115/1.4005175]
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Morphometric Differences between the Medial and Lateral Meniscus in Healthy Men - A Three-Dimensional Analysis Using Magnetic Resonance Imaging
    Bloecker, K.
    Wirth, W.
    Hudelmaier, M.
    Burgkart, R.
    Frobell, R.
    Eckstein, F.
    CELLS TISSUES ORGANS, 2012, 195 (04) : 353 - 364
  • [32] Three-dimensional lumbar spine postures measured by magnetic resonance imaging reconstruction
    Cargill, Sara C.
    Pearcy, Mark
    Barry, Mark Darrell
    SPINE, 2007, 32 (11) : 1242 - 1248
  • [33] Three-dimensional quantification of magnetic resonance imaging artifacts associated with shape factors
    Kawabata, Iku
    Imai, Haruki
    Kanno, Zuisei
    Tetsumura, Akemi
    Tsutsumi, Yusuke
    Doi, Hisashi
    Ashida, Maki
    Kurabayashi, Tohru
    Hanawa, Takao
    Yamamoto, Toru
    Ono, Takashi
    DENTAL MATERIALS JOURNAL, 2019, 38 (04) : 638 - 645
  • [34] Three-dimensional reconstruction of fetal abnormalities using ultrasonography and magnetic resonance imaging
    Werner, Heron
    Marcondes, Maene
    Daltro, Pedro
    Fazecas, Tatiana
    Ribeiro, Bianca Guedes
    Nogueira, Renata
    Araujo Junior, Edward
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (20) : 3502 - 3508
  • [35] Reconstruction of Magnetic Resonance Imaging by Three-Dimensional Dual-Dictionary Learning
    Song, Ying
    Zhu, Zhen
    Lu, Yang
    Liu, Qiegen
    Zhao, Jun
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1285 - 1298
  • [36] Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging
    Ren, Cui
    Zhu, Qiao
    Li, Qing
    Sommer, Stefan
    Zhang, Xianchang
    Yuan, Huishu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4141 - 4154
  • [37] Global optimization of mutual information: application to three-dimensional retrospective registration of magnetic resonance images
    He, RJ
    Narayana, PA
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (04) : 277 - 292
  • [38] Accurate three-dimensional registration of magnetic resonance images for detecting local changes in cartilage thickness
    Cheng, Yuanzhi
    Jin, Quan
    Zhao, Jie
    Guo, Changyong
    Bai, Jing
    JOURNAL OF ELECTRONIC IMAGING, 2011, 20 (02)
  • [39] Kinematics of the lumbar spine in trunk rotation: in vivo three-dimensional analysis using magnetic resonance imaging
    Ryutaro Fujii
    Hironobu Sakaura
    Yoshihiro Mukai
    Noboru Hosono
    Takahiro Ishii
    Motoki Iwasaki
    Hideki Yoshikawa
    Kazuomi Sugamoto
    European Spine Journal, 2007, 16 : 1867 - 1874
  • [40] Kinematics of the lumbar spine in trunk rotation: in vivo three-dimensional analysis using magnetic resonance imaging
    Fujii, Ryutaro
    Sakaura, Hironobu
    Mukai, Yoshihiro
    Hosono, Noboru
    Ishii, Takahiro
    Iwasaki, Motoki
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    EUROPEAN SPINE JOURNAL, 2007, 16 (11) : 1867 - 1874