Multi-Rigid Image Segmentation and Registration for the Analysis of Joint Motion From Three-Dimensional Magnetic Resonance Imaging

被引:12
|
作者
Hu, Yangqiu [1 ,2 ]
Ledoux, William R. [3 ,4 ,5 ]
Fassbind, Michael [3 ]
Rohr, Eric S. [3 ]
Sangeorzan, Bruce J. [3 ,5 ]
Haynor, David [1 ,2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[3] VA Ctr Excellence Limb Loss Prevent & Prosthet En, Seattle, WA 98108 USA
[4] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[5] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 10期
关键词
joint motion; MRI; segmentation; registration; visualization; ANKLE; SUBTALAR; KINEMATICS; FOOT; MR;
D O I
10.1115/1.4005175
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an image segmentation and registration method for studying joint morphology and kinematics from in vivo magnetic resonance imaging (MRI) scans and its application to the analysis of foot and ankle joint motion. Using an MRI-compatible positioning device, a foot was scanned in a single neutral and seven other positions ranging from maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation. A segmentation method combining graph cuts and level set was developed. In the subsequent registration step, a separate rigid body transformation for each bone was obtained by registering the neutral position dataset to each of the other ones, which produced an accurate description of the motion between them. The segmentation algorithm allowed a user to interactively delineate 14 foot bones in the neutral position volume in less than 30 min total (user and computer processing unit [CPU]) time. Registration to the seven other positions took approximately 10 additional minutes of user time and 5.25 h of CPU time. For validation, our results were compared with those obtained from 3DViewnix, a semiautomatic segmentation program. We achieved excellent agreement, with volume overlap ratios greater than 88% for all bones excluding the intermediate cuneiform and the lesser metatarsals. For the registration of the neutral scan to the seven other positions, the average overlap ratio is 94.25%, while the minimum overlap ratio is 89.49% for the tibia between the neutral position and position 1, which might be due to different fields of view (FOV). To process a single foot in eight positions, our tool requires only minimal user interaction time (less than 30 min total), a level of improvement that has the potential to make joint motion analysis from MRI practical in research and clinical applications. [DOI: 10.1115/1.4005175]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Three-dimensional reconstruction of subject-specific knee joint using computed tomography and magnetic resonance imaging image data fusions
    Dong, Yuefu
    Mou, Zhifang
    Huang, Zhenyu
    Hu, Guanghong
    Dong, Yinghai
    Xu, Qingrong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (10) : 1083 - 1093
  • [22] Learning curve for fusion magnetic resonance imaging targeted prostate biopsy and three-dimensional transrectal ultrasonography segmentation
    Lenfant, Louis
    Beitone, Clement
    Troccaz, Jocelyne
    Roupret, Morgan
    Seisen, Thomas
    Voros, Sandrine
    Mozer, Pierre C.
    BJU INTERNATIONAL, 2024, 133 (06) : 709 - 716
  • [23] Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
    Klimes, Filip
    Voskrebenzev, Andreas
    Wacker, Frank
    Vogel-Claussen, Jens
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (208):
  • [24] The Most Accurate Technique and Formulation for Prostate Volume Estimation: A Comparative Analysis of Transrectal Ultrasonography, Magnetic Resonance Imaging, and Three-Dimensional Segmentation
    Citgez, Sinharib
    Sahin, Kadir C.
    Kalender, Goktug
    Gultekin, Mehmet H.
    Sayili, Ugurcan
    Sertbudak, Ipek
    Gurses, Iclal
    Ozkara, Hamdi
    JOURNAL OF ENDOUROLOGY, 2025,
  • [25] Patellar calcar: morphometric analysis by knee magnetic resonance imaging and three-dimensional reconstruction software-assisted
    Benavente, Sergio
    Villagra, Joaquin
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (12) : 1483 - 1488
  • [26] Evaluation of translation in the normal and dysplastic hip using three-dimensional magnetic resonance imaging and voxel-based registration
    Akiyama, K.
    Sakai, T.
    Koyanagi, J.
    Yoshikawa, H.
    Sugamoto, K.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 (06) : 700 - 710
  • [27] Three-dimensional visualization of teeth by magnetic resonance imaging during speech
    Ventura, Sandra R.
    Freitas, Diamantino R.
    Ramos, Isabel M.
    Tavares, Joao Manuel R. S.
    BIODENTAL ENGINEERING II, 2014, : 13 - 17
  • [28] Analysis of Three-dimensional Magnetic Resonance Human Liver Images
    Strzelecki, Michal
    Lee, Malrey
    IETE JOURNAL OF RESEARCH, 2011, 57 (03) : 237 - 245
  • [29] Three-Dimensional Cardiac Tissue Image Registration for Analysis of In Vivo Electrical Mapping
    Mark L. Trew
    Bryan J. Caldwell
    Gregory B. Sands
    Ian J. LeGrice
    Bruce H. Smaill
    Annals of Biomedical Engineering, 2011, 39 : 235 - 248
  • [30] Three-Dimensional Cardiac Tissue Image Registration for Analysis of In Vivo Electrical Mapping
    Trew, Mark L.
    Caldwell, Bryan J.
    Sands, Gregory B.
    LeGrice, Ian J.
    Smaill, Bruce H.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) : 235 - 248