Multi-Rigid Image Segmentation and Registration for the Analysis of Joint Motion From Three-Dimensional Magnetic Resonance Imaging

被引:12
|
作者
Hu, Yangqiu [1 ,2 ]
Ledoux, William R. [3 ,4 ,5 ]
Fassbind, Michael [3 ]
Rohr, Eric S. [3 ]
Sangeorzan, Bruce J. [3 ,5 ]
Haynor, David [1 ,2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[3] VA Ctr Excellence Limb Loss Prevent & Prosthet En, Seattle, WA 98108 USA
[4] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[5] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 10期
关键词
joint motion; MRI; segmentation; registration; visualization; ANKLE; SUBTALAR; KINEMATICS; FOOT; MR;
D O I
10.1115/1.4005175
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an image segmentation and registration method for studying joint morphology and kinematics from in vivo magnetic resonance imaging (MRI) scans and its application to the analysis of foot and ankle joint motion. Using an MRI-compatible positioning device, a foot was scanned in a single neutral and seven other positions ranging from maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation. A segmentation method combining graph cuts and level set was developed. In the subsequent registration step, a separate rigid body transformation for each bone was obtained by registering the neutral position dataset to each of the other ones, which produced an accurate description of the motion between them. The segmentation algorithm allowed a user to interactively delineate 14 foot bones in the neutral position volume in less than 30 min total (user and computer processing unit [CPU]) time. Registration to the seven other positions took approximately 10 additional minutes of user time and 5.25 h of CPU time. For validation, our results were compared with those obtained from 3DViewnix, a semiautomatic segmentation program. We achieved excellent agreement, with volume overlap ratios greater than 88% for all bones excluding the intermediate cuneiform and the lesser metatarsals. For the registration of the neutral scan to the seven other positions, the average overlap ratio is 94.25%, while the minimum overlap ratio is 89.49% for the tibia between the neutral position and position 1, which might be due to different fields of view (FOV). To process a single foot in eight positions, our tool requires only minimal user interaction time (less than 30 min total), a level of improvement that has the potential to make joint motion analysis from MRI practical in research and clinical applications. [DOI: 10.1115/1.4005175]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Image segmentation and registration for the analysis of joint motion from 3D MRI
    Hu, Yangqiu
    Haynor, David R.
    Fassbind, Michael
    Rohr, Eric
    Ledoux, William
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [2] Three-dimensional magnetic resonance myocardial motion tracking from a single image plane
    Abd-Elmoniem, Khaled Z.
    Osman, Nael F.
    Prince, Jerry L.
    Stuber, Matthias
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) : 92 - 102
  • [3] Three-dimensional automatic segmentation of ventricular brain structures in magnetic resonance imaging
    Vera, Miguel
    Molina, Valentin
    Huerfano, Yoleidy
    Vera, Maria
    Del Mar, Atilio
    Salazar, Williams
    Wilches-Duran, Sandra
    Graterol-Rivas, Modesto
    Rojas, Joselyn
    Garicano, Carlos
    Pena, Armando
    Contreras-Velasquez, Julio
    Arias, Victor
    Chacon, Jose
    REVISTA LATINOAMERICANA DE HIPERTENSION, 2016, 11 (02): : 20 - 24
  • [4] Retrospective rigid motion correction of three-dimensional magnetic resonance fingerprinting of the human brain
    Kurzawski, Jan W.
    Cencini, Matteo
    Peretti, Luca
    Gomez, Pedro A.
    Schulte, Rolf F.
    Donatelli, Graziella
    Cosottini, Mirco
    Cecchi, Paolo
    Costagli, Mauro
    Retico, Alessandra
    Tosetti, Michela
    Buonincontri, Guido
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2606 - 2615
  • [5] Magnetic resonance imaging verification of anterior capsular impingement in the hip joint: A three-dimensional analysis
    Hyakutake, Subaru
    Tateuchi, Hiroshige
    Yagi, Masahide
    Itsuda, Hikari
    Wang, Zimin
    Nakai, Ryusuke
    Ichihashi, Noriaki
    CLINICAL BIOMECHANICS, 2024, 120
  • [6] Real-time image-based rigid registration of three-dimensional ultrasound
    Schneider, Robert J.
    Perrin, Douglas P.
    Vasilyev, Nikolay V.
    Marx, Gerald R.
    del Nido, Pedro J.
    Howe, Robert D.
    MEDICAL IMAGE ANALYSIS, 2012, 16 (02) : 402 - 414
  • [7] A slice-to-volume registration method based on real-time magnetic resonance imaging for measuring three-dimensional kinematics of the knee
    Lin, Cheng-Chung
    Zhang, Shuo
    Frahm, Jens
    Lu, Tung-Wu
    Hsu, Chao-Yu
    Shih, Ting-Fang
    MEDICAL PHYSICS, 2013, 40 (10)
  • [8] Balanced multi-image demons for non-rigid registration of magnetic resonance images
    Mesin, Luca
    MAGNETIC RESONANCE IMAGING, 2020, 74 : 128 - 138
  • [9] Magnetic Resonance Image Analysis of Ankle Joint Motion Injury in Athletes
    Cui, Bo
    Liu, Yan
    Liu, Xiaohua
    Jie, Mufu
    Chen, Lijun
    Chen, Shuxiang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (06) : 1346 - 1351
  • [10] Two and Three-Dimensional Segmentation of Hyperpolarized 3He Magnetic Resonance Imaging of Pulmonary Gas Distribution
    Heydarian, Mohammadreza
    Kirby, Miranda
    Wheatley, Andrew
    Fenster, Aaron
    Parraga, Grace
    MEDICAL IMAGING 2012: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2012, 8317