Accuracy of Segmented Le Fort I Osteotomy with Virtual Planning in Orthognathic Surgery Using Patient-Specific Implants: A Case Series

被引:9
作者
Rios, Olina [1 ]
Lerhe, Barbara [1 ]
Chamorey, Emmanuel [2 ]
Savoldelli, Charles [1 ]
机构
[1] Head & Neck Inst, Dept Oral & Maxillofacial Surg, F-06100 Nice, France
[2] Antoine Lacassagne Ctr, Dept Stat, F-06100 Nice, France
关键词
segmented Le Fort I osteotomy; orthognathic surgery; patient-specific implants; virtual surgical planning; BEAM COMPUTED-TOMOGRAPHY; TITANIUM PLATES; SUPERIMPOSITION; OSTEOSYNTHESIS; FEASIBILITY; EXPANSION; MAXILLA; DESIGN; GUIDES;
D O I
10.3390/jcm11195495
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: When maxillary transversal expansion is needed, two protocols of treatment can be used: a maxillary orthodontic expansion followed by a classical bimaxillary osteotomy or a bimaxillary osteotomy with maxillary segmentation. The aim of this study was to assess the accuracy of segmented Le Fort I osteotomy using computer-aided orthognathic surgery and patient-specific titanium plates in patients who underwent a bimaxillary osteotomy for occlusal trouble with maxillary transversal insufficiencies. Methods: A virtual simulation of a Le Fort I osteotomy with maxillary segmentation, a sagittal split ramus osteotomy, and genioplasty (if needed) was conducted on a preoperative three-dimensional (3D) model of each patient's skull using ProPlan CMF 3.0 software (Materialise, Leuven, Belgium). Computer-assisted osteotomy saw-and-drill guides and patient-specific implants (PSIs, titanium plates) were produced and used during the surgery. We chose to focus on the maxillary repositioning accuracy by comparing the preoperative virtual surgical planning and the postoperative 3D outcome skulls using surface superimpositions and 13 standard dental and bone landmarks. Errors between these preoperative and postoperative landmarks were calculated and compared to discover if segmental maxillary repositioning using PSIs was accurate enough to be safely used to treat transversal insufficiencies. Results: A total of 22 consecutive patients-15 females and 7 males, with a mean age of 27.4 years-who underwent bimaxillary computer-assisted orthognathic surgery with maxillary segmentation were enrolled in the study. All patients presented with occlusion trouble, 13 with Class III malocclusions (59%) and 9 (41%) with Class II malocclusions. A quantitative analysis revealed that, overall, the mean absolute discrepancies for the x-axis (transversal dimension), y-axis (anterior-posterior dimensions), and z-axis (vertical dimension) were 0.59 mm, 0.74 mm, and 0.56 mm, respectively. The total error rate of maxillary repositioning was 0.62 mm between the postoperative cone-beam computed tomography (CBCT) and the preoperatively planned 3D skull. According to the literature, precision in maxilla repositioning is defined by an error rate (clinically relevant) at each landmark of <2 mm and a total error of <2 mm for each patient. Conclusions: A high degree of accuracy between the virtual plan and the postoperative result was observed.
引用
收藏
页数:11
相关论文
共 44 条
  • [1] 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - Our experience in 16 cases
    Aboul-Hosn Centenero, Samir
    Hernandez-Alfaro, Federico
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (02) : 162 - 168
  • [2] Akbari Maryam, 2016, Dent Res J (Isfahan), V13, P387
  • [3] Alhammadi Maged Sultan, 2018, Dental Press J. Orthod., V23, p40.e1
  • [4] Comparison of the Accuracy of Voxel Based Registration and Surface Based Registration for 3D Assessment of Surgical Change following Orthognathic Surgery
    Almukhtar, Anas
    Ju, Xiangyang
    Khambay, Balvinder
    McDonald, James
    Ayoub, Ashraf
    [J]. PLOS ONE, 2014, 9 (04):
  • [5] Investigation of the biomechanical stability of Cfr-PEEK in the treatment of mandibular angulus fractures by finite element analysis
    Avci, Tolunay
    Omezli, Mehmet Melih
    Torul, Damla
    [J]. JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2022, 123 (06) : 610 - 615
  • [6] A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser
    Baan, Frank
    Liebregts, Jeroen
    Xi, Tong
    Schreurs, Ruud
    de Koning, Martien
    Berge, Stefaan
    Maal, Thomas
    [J]. PLOS ONE, 2016, 11 (02):
  • [7] Functional needs of subjects with dentofacial deformities: A study using the index of orthognathic functional treatment need (IOFTN)
    Borzabadi-Farahani, Ali
    Eslamipour, Faezeh
    Shahmoradi, Majid
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2016, 69 (06) : 796 - 801
  • [8] Custom-Machined Miniplates and Bone-Supported Guides for Orthognathic Surgery: A New Surgical Procedure
    Brunso, Joan
    Franco, Maria
    Constantinescu, Thomas
    Barbier, Luis
    Andoni Santamaria, Joseba
    Alvarez, Julio
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (05) : 1061.e1 - 1061.e12
  • [9] Superimposition of 3D cone-beam CT models of orthognathic surgery patients
    Cevidanes, LHS
    Bailey, LJ
    Tucker, GR
    Styner, MA
    Mol, A
    Phillips, CL
    Proffit, WR
    Turvey, T
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (06) : 369 - 375
  • [10] Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery
    Cevidanes, Lucia H. S.
    Bailey, L'Tanya J.
    Tucker, Scott F.
    Styner, Martin A.
    Mol, Andre
    Phillips, Ceib L.
    Proffit, William R.
    Turvey, Timothy
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (01) : 44 - 50