Accuracy of Segmented Le Fort I Osteotomy with Virtual Planning in Orthognathic Surgery Using Patient-Specific Implants: A Case Series

被引:8
|
作者
Rios, Olina [1 ]
Lerhe, Barbara [1 ]
Chamorey, Emmanuel [2 ]
Savoldelli, Charles [1 ]
机构
[1] Head & Neck Inst, Dept Oral & Maxillofacial Surg, F-06100 Nice, France
[2] Antoine Lacassagne Ctr, Dept Stat, F-06100 Nice, France
关键词
segmented Le Fort I osteotomy; orthognathic surgery; patient-specific implants; virtual surgical planning; BEAM COMPUTED-TOMOGRAPHY; TITANIUM PLATES; SUPERIMPOSITION; OSTEOSYNTHESIS; FEASIBILITY; EXPANSION; MAXILLA; DESIGN; GUIDES;
D O I
10.3390/jcm11195495
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: When maxillary transversal expansion is needed, two protocols of treatment can be used: a maxillary orthodontic expansion followed by a classical bimaxillary osteotomy or a bimaxillary osteotomy with maxillary segmentation. The aim of this study was to assess the accuracy of segmented Le Fort I osteotomy using computer-aided orthognathic surgery and patient-specific titanium plates in patients who underwent a bimaxillary osteotomy for occlusal trouble with maxillary transversal insufficiencies. Methods: A virtual simulation of a Le Fort I osteotomy with maxillary segmentation, a sagittal split ramus osteotomy, and genioplasty (if needed) was conducted on a preoperative three-dimensional (3D) model of each patient's skull using ProPlan CMF 3.0 software (Materialise, Leuven, Belgium). Computer-assisted osteotomy saw-and-drill guides and patient-specific implants (PSIs, titanium plates) were produced and used during the surgery. We chose to focus on the maxillary repositioning accuracy by comparing the preoperative virtual surgical planning and the postoperative 3D outcome skulls using surface superimpositions and 13 standard dental and bone landmarks. Errors between these preoperative and postoperative landmarks were calculated and compared to discover if segmental maxillary repositioning using PSIs was accurate enough to be safely used to treat transversal insufficiencies. Results: A total of 22 consecutive patients-15 females and 7 males, with a mean age of 27.4 years-who underwent bimaxillary computer-assisted orthognathic surgery with maxillary segmentation were enrolled in the study. All patients presented with occlusion trouble, 13 with Class III malocclusions (59%) and 9 (41%) with Class II malocclusions. A quantitative analysis revealed that, overall, the mean absolute discrepancies for the x-axis (transversal dimension), y-axis (anterior-posterior dimensions), and z-axis (vertical dimension) were 0.59 mm, 0.74 mm, and 0.56 mm, respectively. The total error rate of maxillary repositioning was 0.62 mm between the postoperative cone-beam computed tomography (CBCT) and the preoperatively planned 3D skull. According to the literature, precision in maxilla repositioning is defined by an error rate (clinically relevant) at each landmark of <2 mm and a total error of <2 mm for each patient. Conclusions: A high degree of accuracy between the virtual plan and the postoperative result was observed.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Accuracy of mandibular anterior subapical osteotomy by virtual planning in orthognathic surgery using patient-specific implants
    Demes, Estelle
    Rios, Olina
    Chamorey, Emmanuel
    Lerhe, Barbara
    D'Andrea, Gregoire
    Savoldelli, Charles
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [2] The use of patient-specific implants in orthognathic surgery: A series of 32 maxillary osteotomy patients
    Suojanen, Juho
    Leikola, Junnu
    Stoor, Patricia
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (12) : 1913 - 1916
  • [3] Accuracy of Patient-Specific Implants in Virtually Planned Segmental Le Fort I Osteotomies
    Kuehle, Reinald
    Scheurer, Mats
    Bouffleur, Frederic
    Fuchs, Jennifer
    Engel, Michael
    Hoffmann, Juergen
    Freudlsperger, Christian
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [4] Patient-Specific Implants in Orthognathic Surgery
    Li, Dion Tik Shun
    Leung, Yiu Yan
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2023, 35 (01) : 61 - 69
  • [5] Splintless surgery: does patient-specific CAD-CAM osteosynthesis improve accuracy of Le Fort I osteotomy?
    Kraeima, J.
    Jansma, J.
    Schepers, R. H.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (10): : 1085 - 1089
  • [6] The use of patient-specific implants in orthognathic surgery: A series of 30 mandible sagittal split osteotomy patients
    Suojanen, Juho
    Leikola, Junnu
    Stoor, Patricia
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 990 - 994
  • [7] Hybrid osteosynthesis in orthognathic surgery: 28 cases of Le Fort I osteotomy
    Caquant, L.
    Freidel, M.
    Bouletreau, P.
    Breton, P.
    REVUE DE STOMATOLOGIE ET DE CHIRURGIE MAXILLO-FACIALE, 2007, 108 (06): : 489 - 495
  • [8] On the feasibility of minimally invasive Le Fort I with patient-specific implants: Proof of concept
    Hernandez-Alfaro, Federico
    Saavedra, Oscar
    Duran-Valles, Francesc
    Valls-Ontanon, Adaia
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (03)
  • [9] Early experience of wafer-free Le Fort I osteotomy with patient-specific implants in cleft lip and palate patients
    Merta, Minna
    Heliovaara, Arja
    Leikola, Junnu
    Suojanen, Juho
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2023, 77 : 78 - 86
  • [10] Virtual Surgical Planning and Patient-Specific Implants in Facial Feminization Surgery
    Alperovich, Michael
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2022, 24 : S20 - S23