An automatic body ROI determination for 3D visualization of a fetal ultrasound volume

被引:0
|
作者
Nguyen, TD [1 ]
Kim, SH
Kim, NC
机构
[1] Kyungpook Natl Univ, Dept Elect Engn, Lab Visual Commun, Taegu 702701, South Korea
[2] Youngsan Univ, Dept Multimedia Engn, Yangsan 626847, South Korea
来源
KNOWLEDGE-BASED INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS, PT 2, PROCEEDINGS | 2005年 / 3682卷
关键词
fetal ultrasound volume; visualization; region-of-interest; significant local minimum; support vector machines;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents an efficient method to determine a body region-of-interest (ROI) enclosing a fetus in a two-dimensional (2D) key frame that removes some irrelevant matters such as the abdominal area in front of a fetus to visualize a fetal ultrasound volume along with the key frame. In the body ROI determination, a clear frontal view of a fetus lying down floating in amniotic fluid mainly depends on the successful determination of the top bound among the four bounds of an ROI The key idea of our top-bound setting is to locate it in amniotic fluid areas between a fetus and its mother's abdomen, which are dark so as to typically induce local minima of the vertical projection of a key frame. The support vector machines (SVM) classifier, known as an effective tool for classification, tests whether the candidate top bound, located at each of the local minima which are sorted in an increasing order, is valid or not. The test, using textural characterization of neighbor regions around each candidate bound, determines the first valid one as the top bound. The body ROI determination rate as well as resulting 3D images demonstrate that our system could replace a user in allocation of a fetus for its 3D visualization.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 50 条
  • [1] Improving the visualization of 3D ultrasound data with 3D filtering
    Shamdasani, V
    Bae, U
    Managuli, R
    Kim, Y
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 455 - 461
  • [2] Artifact removal and texture-based rendering for visualization of 3D fetal ultrasound images
    Wang, Shyh-Roei
    Sun, Yung-Nien
    Chang, Fong-Ming
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (06) : 575 - 588
  • [3] Artifact removal and texture-based rendering for visualization of 3D fetal ultrasound images
    Shyh-Roei Wang
    Yung-Nien Sun
    Fong-Ming Chang
    Medical & Biological Engineering & Computing, 2008, 46 : 575 - 588
  • [4] Solid object visualization of 3D ultrasound data
    Nelson, TR
    Bailey, MJ
    MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 : 26 - 34
  • [5] Automatic Tumor Diagnosis for Breast Ultrasound using 3D Sub-volume Registration
    Chen, Chii-Jen
    Chang, Ruey-Feng
    Chen, Dar-Ren
    2009 9TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, 2009, : 61 - +
  • [6] 3D Reconstruction Methods Purporting 3D Visualization and Volume Estimation of Brain Tumors
    Joseph, Sushitha Susan
    Aju, D.
    INTERNATIONAL JOURNAL OF E-COLLABORATION, 2022, 18 (01)
  • [7] An Intelligent Breast Ultrasound System for Diagnosis and 3D Visualization
    Lu, Yuanyuan
    Chen, Yunqing
    Chen, Cheng
    Li, Junlai
    He, Kunlun
    Xiao, Ruoxiu
    ELECTRONICS, 2022, 11 (14)
  • [8] 3D segmentation and visualization of lung volume using CT
    Zhang, HB
    Sun, XJ
    Duan, HC
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 538 - 546
  • [9] 3D Medical Image Visualization and Volume Estimation of Pathology Zones
    Krechetova, K.
    Glaz, A.
    Platkajis, A.
    14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 532 - +
  • [10] Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
    Mota, Ana M.
    Clarkson, Matthew J.
    Almeida, Pedro
    Matela, Nuno
    JOURNAL OF IMAGING, 2020, 6 (07)