Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis

被引:9
作者
Jabran, Ali [1 ]
Peach, Chris [1 ,2 ]
Zou, Zhenmin [1 ]
Ren, Lei [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Sackville St, Manchester M13 9PL, Lancs, England
[2] Univ Hosp South Manchester, Dept Shoulder & Elbow Surg, Southmoor Rd, Manchester M23 9LT, Lancs, England
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
关键词
Biomechanical analysis; Proximal humerus fractures; Plate fixation; Blade plate; Locking plate; HUMAN SHOULDER SPECIMENS; ROTATOR CUFF; COMPRESSION PLATE; STABLE PLATE; HEAD; CLASSIFICATION; STABILIZATION; COMPLICATIONS; FAILURE; SUPPORT;
D O I
10.1186/s12938-018-0447-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate). Methods: A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs' resistance to varus collapse. Results: In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001). Conclusions: In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS).
引用
收藏
页数:12
相关论文
共 40 条
[1]   Analysis of efficacy and failure in proximal humerus fractures treated with locking plates [J].
Agudelo, Juan ;
Schuermann, Matthias ;
Stahel, Philip ;
Helwig, Peter ;
Morgan, Steven J. ;
Zechel, Wolfgang ;
Bahrs, Christian ;
Parekh, Anand ;
Ziran, Bruce ;
Williams, Allison ;
Smith, Wade .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (10) :676-681
[2]   Complications encountered in proximal humerus fractures treated with locking plate fixation [J].
Aksu, Neslihan ;
Gogus, Abdullah ;
Kara, Ayhan Nedim ;
Isiklar, Zekeriya Ugur .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (02) :89-96
[3]   The epidemiology of peripheral fractures [J].
Baron, JA ;
Barrett, JA ;
Karagas, MR .
BONE, 1996, 18 (03) :S209-S213
[4]   Evaluation of the Neer system of classification of proximal humeral fractures with computerized tomographic scans and plain radiographs [J].
Bernstein, J ;
Adler, LM ;
Blank, JE ;
Dalsey, RM ;
Williams, GR ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1371-1375
[5]   Internal fixation of proximal humeral fractures with a locking compression plate -: A retrospective evaluation of 72 patients followed for a minimum of 1 year [J].
Björkenheim, JM ;
Pajarinen, J ;
Savolainen, V .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :741-745
[6]   Proximal humeral fracture fixation: locking plate construct ± intramedullary fibular allograft [J].
Chow, Roxanne M. ;
Begum, Farhana ;
Beaupre, Lauren A. ;
Carey, Jason P. ;
Adeeb, Samer ;
Bouliane, Martin J. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (07) :894-901
[7]   Pitfalls and complications with locking plate for proximal humerus fracture [J].
Clavert, Philippe ;
Adam, Philippe ;
Bevort, Adrien ;
Bonnomet, Francois ;
Kempf, Jean-Francois .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) :489-494
[8]   The impacted varus (A2.2) proximal humeral fracture - Prediction of outcome and results of nonoperative treatment in 99 patients [J].
Court-Brown, CM ;
McQueen, MM .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :736-740
[9]  
Dheerendra SK., 2011, SHOULDER ELB, V3, P74, DOI [10.1111/j.1758-5740.2011.00106.x, DOI 10.1111/J.1758-5740.2011.00106.X]
[10]   Two-part surgical neck fractures of the proximal part of the humerus - A biomechanical evaluation of two fixation nchniques [J].
Edwards, Sara L. ;
Wilson, Nicole A. ;
Zhang, Li-Qun ;
Flores, Steven ;
Merk, Bradley R. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2258-2264