Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase

被引:9
作者
Lehmann, W
Blauth, M
Briem, D
Schmidt, U [1 ]
机构
[1] Hannover Med Sch, Dept Trauma Surg, D-3000 Hannover, Germany
[2] Univ Hamburg, Sch Med, Dept Trauma Surg, Hamburg, Germany
关键词
cervical spine; anterior plate fixation; biomechanics;
D O I
10.1007/s00586-003-0578-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Anterior plate fixation with unicortical screw purchase does not involve the risk of posterior cortex penetration and possible injuries of the spinal cord. However, there are very few biomechanical data about the immediate stability of non-locking plate fixation with unicortical or bicortical screw placement. The aim of the present study was to evaluate the immediate biomechanical properties in terms of flexibility of a non-locking anterior plate system with 4.5-mm screw fixation and unicortical or bicortical screw purchase applied to a single destabilized cervical spine motion segment. Using fresh cadaveric cervical spine specimens C3-C7, multidirectional flexibility was measured at the level C4-C5 before and after destabilization and fixation with an anterior plate with either unicortical or bicortical screw purchase. The results showed that fixed cervical spine segments with anterior plate and bicortical screw purchase were more rigid than intact specimens in all modes of testing. The difference was statistically significant for flexion and extension (P<0.001). Plate fixation with unicortical screw purchase had statistically significant decreased ranges of motion compared to the intact specimen only in extension. Neither unicortical nor bicortical screw purchase decreased the range of motion significantly in axial rotation compared to the intact specimens. This in vitro study documented that neither unicortical nor bicortical screw purchase with non-locking plate fixation can increase stability in all modes of testing, in axial rotation in particular. Direct comparison between the group with uni- and that with bicortical screw fixation did not reveal significant differences, and therefore no advantage was shown for either type of screw fixation. Therefore, we demonstrated that both uni- and bicortical screw purchase with non-locking plate fixation can decrease immediate flexibility of the tested motion segment, with better results for bicortical purchase. No significant differences were found comparing the two groups of screw fixation. These data suggest that unicortical screw fixation can be used for anterior plate fixation with a comparable immediate stability to bicortical screw fixation.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 35 条
[21]   BIOMECHANICAL EVALUATION OF SPINAL FIXATION DEVICES .1. A CONCEPTUAL-FRAMEWORK [J].
PANJABI, MM .
SPINE, 1988, 13 (10) :1129-1134
[22]   Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating [J].
Pitzen, T ;
Barbier, D ;
Tintinger, F ;
Steudel, WI ;
Strowitzki, M .
EUROPEAN SPINE JOURNAL, 2002, 11 (05) :494-499
[23]   Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study [J].
Pitzen, T ;
Wilke, HJ ;
Caspar, W ;
Claes, L ;
Steudel, WI .
EUROPEAN SPINE JOURNAL, 1999, 8 (05) :382-387
[24]   BIOMECHANICAL EVALUATION OF CERVICAL-SPINE STABILIZATION METHODS USING A PORCINE MODEL [J].
RICHAMN, JD ;
DANIEL, TE ;
ANDERSON, DD ;
MILLER, PL ;
DOUGLAS, RA .
SPINE, 1995, 20 (20) :2192-2197
[25]   Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine -: In vitro comparison with two established internal fixation systems [J].
Richter, M ;
Wilke, HJ ;
Kluger, P ;
Claes, L ;
Puhl, W .
SPINE, 1999, 24 (03) :207-212
[26]   SERIES OF 92 TRAUMATIC CERVICAL-SPINE INJURIES STABILIZED WITH ANTERIOR ASIF PLATE FUSION TECHNIQUE [J].
RIPA, DR ;
KOWALL, MG ;
MEYER, PR ;
RUSIN, JJ .
SPINE, 1991, 16 (03) :S46-S55
[27]   ASSESSMENT OF UNICORTICAL AND BICORTICAL FIXATION IN A QUASI-STATIC CADAVERIC MODEL - ROLE OF BONE-MINERAL DENSITY AND SCREW TORQUE [J].
RYKEN, TC ;
GOEL, VK ;
CLAUSEN, JD ;
TRAYNELIS, VC .
SPINE, 1995, 20 (17) :1861-1867
[28]   AN IN-VITRO BIOMECHANICAL COMPARISON OF THE OROSCO AND AO LOCKING PLATES FOR ANTERIOR CERVICAL-SPINE FIXATION [J].
SMITH, SA ;
LINDSEY, RW ;
DOHERTY, BJ ;
ALEXANDER, J ;
DICKSON, JH .
JOURNAL OF SPINAL DISORDERS, 1995, 8 (03) :220-223
[29]   The effect of locking fixation screws on the stability of anterior cervical plating [J].
Spivak, JM ;
Chen, DY ;
Kummer, FJ .
SPINE, 1999, 24 (04) :334-338
[30]   A BIOMECHANICAL EVALUATION OF CERVICAL SPINAL STABILIZATION METHODS IN A BOVINE MODEL - STATIC AND CYCLICAL LOADING [J].
SUTTERLIN, CE ;
MCAFEE, PC ;
WARDEN, KE ;
REY, RM ;
FAREY, ID .
SPINE, 1988, 13 (07) :795-802