Correlation Between Histomorphometric and Micro-computed Tomography Analysis of Periapical Lesions in Mice Model

被引:2
作者
Holanda de Oliveira, Katharina Morant [1 ]
Bezerra da Silva, Raquel Assed [1 ]
Kuechler, Erika Calvano [1 ]
de Queiroz, Alexandra Mussolino [1 ]
Nelson Filho, Paulo [1 ]
Bezerra da Silva, Lea Assed [1 ]
机构
[1] Univ Sao Paulo, Dept Pediat Clin, Sch Dent Ribeirao Preto, BR-14040904 Ribeirao Preto, Brazil
关键词
Micro-computed tomography; mice; periapical lesion; RECEPTOR; TEETH;
D O I
10.3109/01913123.2014.975389
中图分类号
TH742 [显微镜];
学科分类号
摘要
Periapical lesions are processes mediated from bacterial invasion on the pulp tissue, which results in inflammatory process and bone resorption. Animal models have been used for the study of cell interactions and inflammatory responses involved in periapical lesion. The use of different methods for morphometric evaluation of this lesion has been reported. However, due to the limitation of 2D methods, computerized microtomography (mu CT) has been indicated. Therefore, the aim of this study was to evaluate the correlation between the histomorphometric measures of periapical lesions and the mu CT analysis obtained in an animal experimental model. Briefly, the periapical lesions were induced by pulp exposal and after the experimental periods (7, 21 and 42 days) the mice were euthanized. The mandibles were evaluated under the mu CT scanning and then were subjected to the routine histologic procedures, stained with hematoxilin and eosin. The periapical lesions were measured by the specific softwares of each technique. A weak correlation among the histomorphometric measurement and the 2D mu CT analysis (r(2) = .204) and between the histomorphometric measurement and the 3D mu CT analysis (r(2) = .237) was observed. A strong correlation between the 2D and 3D mu CT analysis (r(2) = .867) was observed. Thereby, it can be concluded that the mu CT is a method that allows a precise volumetric scanning and represents an important tool for morphometric evaluation.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [1] Quantification of periapical bone destruction in mice by micro-computed tomography
    Balto, K
    Müller, R
    Carrington, DC
    Dobeck, J
    Stashenko, P
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (01) : 35 - 40
  • [2] Three-Dimensional Micro-Computed Tomography Analyses of Induced Periapical Lesions in Transgenic Mice
    Holanda de Oliveira, Katharina Morant
    Nelson-Filho, Paulo
    Bezerra da Silva, Lea Assed
    Kuechler, Erika Calvano
    Gaton-Hernandez, Patricia
    Bezerra da Silva, Raquel Assed
    ULTRASTRUCTURAL PATHOLOGY, 2015, 39 (06) : 402 - 407
  • [3] Use of micro-computed tomography for the assessment of periapical lesions in small rodents: a systematic review
    Kalatzis-Sousa, N. G.
    Spin-Neto, R.
    Wenzel, A.
    Tanomaru-Filho, M.
    Faria, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (04) : 352 - 366
  • [4] Histomorphometric and Micro-computed Tomography Analysis of Pulpal Response to Three Different Pulp Capping Materials
    Al-Hezaimi, Khalid
    Salameh, Ziad
    Al-Fouzan, Khalid
    Al Rejaie, Mansour
    Tay, Franklin R.
    JOURNAL OF ENDODONTICS, 2011, 37 (04) : 507 - 512
  • [5] Accuracy and reliability of enamel and dentin thickness measurements on micro-computed tomography and digital periapical radiographs
    Belgin, Ceren Aktuna
    Serindere, Gozde
    Orhan, Kaan
    JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2019, 18 : 32 - 36
  • [6] Correlation between micro-computed tomography and histomorphometry for assessment of new bone formation in a calvarial experimental model
    Yeom, Heyri
    Blanchard, Steven
    Kim, SeokJin
    Zunt, Susan
    Chu, Tien-Min G.
    JOURNAL OF CRANIOFACIAL SURGERY, 2008, 19 (02) : 446 - 452
  • [7] Micro-computed tomography of early lesions of osteochondrosis in the tarsus of foals
    Olstad, Kristin
    Cnudde, Veerle
    Masschaele, Bert
    Thomassen, Ragnar
    Dolvik, Nils Ivar
    BONE, 2008, 43 (03) : 574 - 583
  • [8] Comparison of the ossification centre images between standard computed tomography and micro-computed tomography
    Wang, W.
    Wang, X.
    Ren, X.
    Chen, L.
    Li, Z.
    Li, X.
    Zhang, P.
    Gao, J.
    Su, B.
    Zhang, S.
    FOLIA MORPHOLOGICA, 2020, 79 (01) : 141 - 147
  • [9] Evaluation of hyaluronic matrix efficacy in sinus augmentation: a randomized-controlled histomorphometric and micro-computed tomography analysis
    Dogan, E.
    Dursun, E.
    Tosun, E.
    Bilgic, E.
    Akman, A. C.
    Orhan, K.
    Celik, H. H.
    Korkusuz, P.
    Caglayan, F.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (07) : 931 - 937
  • [10] Micro-computed tomography and histomorphometric analysis of human alveolar bone repair induced by laser phototherapy: a pilot study
    Romao, M. M. A.
    Marques, M. M.
    Cortes, A. R. G.
    Horliana, A. C. R. T.
    Moreira, M. S.
    Lascala, C. A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (12) : 1521 - 1528