The effect of platelet-rich plasma upon implant stability measured by resonance frequency analysis in the lower anterior mandibles - A pilot study

被引:51
作者
Monov, G [1 ]
Fuerst, G [1 ]
Tepper, G [1 ]
Watzak, G [1 ]
Zechner, W [1 ]
Watzek, G [1 ]
机构
[1] Univ Vienna, Sch Dent, Ludwig Boltzmann Inst Oral Implantol, Dept Oral Surg, Vienna, Austria
关键词
implant stability; osseointegration; platelet-rich plasma (PRP); resonant frequency analysis (RFA);
D O I
10.1111/j.1600-0501.2005.01157.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Using a one-stage surgical protocol, a total of 34 Branemark Mk-III Ti-Unite implants with a length of 13 mm and a diameter of 3.75 mm were inserted in 10 edentulous mandibles. Of these, seven patients received four and three patients two interforaminal implants. All implants were followed with repeated stability measurements by means of resonance frequency analysis at different time interval: 0, 4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44 days. In quadrant III platelet-rich plasma (PRP) was instilled locally before implant placement, while no PRP was added in quadrant IV to serve as control group (split-mouth design). Results showed no statistically significant difference between the two groups. Nonetheless, both groups (PRP+control) showed a highly significant reduction of the implant stability quotient (P < 0.001) between days 0 and 4. However, no difference was noted between the two groups after day 4, it may be concluded that the instillation of PRP during implant placement in the lower anterior mandible did not add additional benefit.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 44 条
[31]   Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study [J].
Lee, Jungwon ;
Pyo, Se-Wook ;
Cho, Hyun-Jae ;
An, Jung-Sub ;
Lee, Jae-Hyun ;
Koo, Ki-Tae ;
Lee, Yong-Moo .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (01) :56-66
[32]   Stability Measurements of Craniofacial Implants by Means of Resonance Frequency Analysis: 1-Year Clinical Pilot Study [J].
Karakoca-Nemli, Secil ;
Aydin, Cemal ;
Yilmaz, Handan ;
Sarisoy, Senol .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) :187-193
[33]   Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation: A prospective pilot cohort study [J].
Brouwers, Joost E. I. G. ;
Buis, Sharon ;
de Groot, Philip G. ;
de Laat, Bas ;
Remijn, Jasper A. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (05) :789-799
[34]   The effect of platelet-rich plasma on early and late bone healing using a mixture of particulate autogenous cancellous bone and Bio-Oss®: an experimental study in goats [J].
Mooren, R. E. C. M. ;
Dankers, A. C. A. ;
Merkx, M. A. W. ;
Bronkhorst, E. M. ;
Jansen, J. A. ;
Stoelinga, P. J. W. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (04) :371-378
[35]   The influence of implant design on implant stability in low-density bone under guided surgical template in inexperienced surgeons: A pilot randomized controlled clinical trial using resonance frequency analysis [J].
Supachaiyakit, Pinmuk ;
Serichetaphongse, Pravej ;
Chengprapakorn, Wareeratn .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (04) :444-454
[36]   Predicting osseointegration by means of implant primary stability - A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants [J].
Nedir, R ;
Bischof, M ;
Szmukler-Moncler, S ;
Bernard, JP ;
Samson, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) :520-528
[37]   Influence of Implant Geometry on Primary Insertion Stability and Simulated Pen-implant Bone Loss: An In Vitro Study Using Resonance Frequency Analysis and Damping Capacity Assessment [J].
Lachmann, Stefan ;
Laval, Johannes Yves ;
Axmann, Detlef ;
Weber, Heiner .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) :347-355
[38]   Effects of continual intermittent administration of parathyroid hormone on implant stability in the presence of osteoporosis: an in vivo study using resonance frequency analysis in a rabbit model [J].
Oki, Yoshifumi ;
Doi, Kazuya ;
Makihara, Yusuke ;
Kobatake, Reiko ;
Kubo, Takayasu ;
Tsuga, Kazuhiro .
JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (05) :498-505
[39]   Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis [J].
Farronato, Davide ;
Manfredini, Mattia ;
Stocchero, Michele ;
Caccia, Mattia ;
Azzi, Lorenzo ;
Farronato, Marco .
JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) :182-189
[40]   Effect of Demineralized Bone Matrix, Bone Marrow Mesenchymal Stromal Cells, and Platelet-Rich Plasma on Bone Tunnel Healing After Anterior Cruciate Ligament Reconstruction: A Comparative Micro-Computed Tomography Study in a Tendon Allograft Sheep Model [J].
Hexter, Adam T. ;
Karali, Aikaterina ;
Kao, Alex ;
Tozzi, Gianluca ;
Heidari, Nima ;
Petrie, Aviva ;
Boyd, Ashleigh ;
Kalaskar, Deepak M. ;
Pendegrass, Catherine ;
Rodeo, Scott ;
Haddad, Fares ;
Blunn, Gordon .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (09)