Effects of magnetic field strength and b value on the sensitivity and specificity of quantitative breast diffusion-weighted MRI

被引:20
作者
Eghtedari, Mohammad [1 ]
Ma, Jingfei [2 ]
Fox, Patricia [3 ]
Guvenc, Inanc [4 ]
Yang, Wei T. [5 ]
Dogan, Basak E. [6 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
[4] Med Pk Hosp, Dept Diagnost Radiol, Ankara, Turkey
[5] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[6] Univ Texas Southwestern Med Ctr Dallas, Dept Diagnost Radiol, Dallas, TX 75390 USA
关键词
Breast MRI; diffusion-weighted imaging (DWI); b value; magnetic field strength; benign and malignant lesions; LESIONS; PERFUSION; CONTRAST;
D O I
10.21037/qims.2016.07.06
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To evaluate the effect of b value or the magnetic field strength (B0) on the sensitivity and specificity of quantitative breast diffusion-weighted imaging (DWI). Methods: A total of 126 patients underwent clinical breast MRI that included pre-contrast DWI imaging using b values of both 1,000 and 1,500 s/mm(2) at either 1.5 T (n=86) or 3.0 T (n=40). Quantitative apparent diffusion coefficients (ADC) were measured and compared for 18 benign, 33 malignant lesions, and 126 normal breast tissues. Optimal ADCmean threshold for differentiating benign and malignant lesions was estimated and the effect of b values and B0 were examined using a generalized estimating equations (GEE) model. Results: The optimal ADCmean threshold was 1.235x10(-3) mm(2)/s for b value of 1,000 and 0.934x10(-3) mm(2)/s for b value of 1,500. Using these thresholds, the sensitivities and specificities were 96% and 89% (b value =1,000, B0 =1.5 T), 89% and 98% (b value =1,000, B0 =3.0 T), 88% and 96% (b value =1,500, B0 =1.5 T), and 67% and 100% (b value =1,500, B0 =3.0 T). No significant difference was found between different B0 (P=0.26) or b values (P=0.28). Conclusions: Better sensitivity is achieved with DWI of b value =1,000 than with b value =1,500. However, b value and B0 do not significantly impact diagnostic performance of DWI when using appropriate thresholds.
引用
收藏
页码:374 / 380
页数:7
相关论文
共 21 条
[1]   Assessment of Breast Lesions With Diffusion-Weighted MRI: Comparing the Use of Different b Values [J].
Arantes Pereira, Fernanda Philadelpho ;
Martins, Gabriela ;
Figueiredo, Eduardo ;
Aidar Domingues, Marisa Nassar ;
Domingues, Romeu Cortes ;
Barbosa da Fonseca, Lea Mirian ;
Gasparetto, Emerson Leandro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :1030-1035
[2]   Diffusion-weighted imaging of normal fibroglandular breast tissue: influence of microperfusion and fat suppression technique on the apparent diffusion coefficient [J].
Baron, Paul ;
Dorrius, Monique D. ;
Kappert, Peter ;
Oudkerk, Matthijs ;
Sijens, Paul E. .
NMR IN BIOMEDICINE, 2010, 23 (04) :399-405
[3]   Diffusion-weighted MR for Differentiation of Breast Lesions at 3.0 T: How Does Selection of Diffusion Protocols Affect Diagnosis? [J].
Bogner, Wolfgang ;
Gruber, Stephan ;
Pinker, Katja ;
Grabner, Guenther ;
Stadlbauer, Andreas ;
Weber, Michael ;
Moser, Ewald ;
Helbich, Thomas H. ;
Trattnig, Siegfried .
RADIOLOGY, 2009, 253 (02) :341-351
[4]   Breast Magnetic Resonance Imaging: Diffusion-Weighted Imaging [J].
Brandao, Alice C. ;
Lehman, Constance D. ;
Partridge, Savannah C. .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2013, 21 (02) :321-+
[5]   Conspicuity of breast lesions at different b values on diffusion-weighted imaging [J].
Chen, Xin ;
He, Xi-Jing ;
Jin, Rui ;
Guo, You-Min ;
Zhao, Xian ;
Kang, Hua-Feng ;
Mo, Li-Ping ;
Wu, Qian .
BMC CANCER, 2012, 12
[6]  
Dietrich O, 2001, MAGNET RESON MED, V45, P448, DOI 10.1002/1522-2594(200103)45:3<448::AID-MRM1059>3.0.CO
[7]  
2-W
[8]   Effect of b value and pre-admission of contrast on diagnostic accuracy of 1.5-T breast DWI: a systematic review and meta-analysis [J].
Dorrius, Monique D. ;
Dijkstra, Hildebrand ;
Oudkerk, Matthijs ;
Sijens, Paul E. .
EUROPEAN RADIOLOGY, 2014, 24 (11) :2835-2847
[9]   Diffusion and perfusion of the breast [J].
Iacconi, Chiara .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (03) :386-390
[10]   Usefulness of diffusion-weighted imaging of breast tumors: quantitative and visual assessment [J].
Inoue, Kaiji ;
Kozawa, Eito ;
Mizukoshi, Waka ;
Tanaka, Junji ;
Saeki, Toshiaki ;
Sakurai, Takaki ;
Kimura, Fumiko .
JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (06) :429-436