Towards In Vivo K-Edge X-Ray Micro-CT with the Pixirad-I/Pixie-III Detector

被引:6
作者
Brun, F. [1 ]
Di Trapani, V. [2 ,3 ]
Dreossi, D. [4 ]
Rigon, L. [1 ,5 ]
Longo, R. [1 ,5 ]
Delogu, P. [2 ,3 ]
机构
[1] Ist Nazl Fis Nucl, Sez Trieste, Via A Valerio 2, I-34127 Trieste, Italy
[2] Univ Siena, Dipartimento Sci Fis Terra & Ambiente, Via Roma 56, I-53100 Siena, Italy
[3] Ist Nazl Fis Nucl, Sez Pisa, Largo B Pontecorvo 3, I-56127 Pisa, Italy
[4] Elettra Sincrotrone Trieste SCpA, SS 14 Km 163-5,Area Sci Pk, I-34149 Trieste, Italy
[5] Univ Trieste, Dipartimento Fis, Via A Valerio 2, I-34127 Trieste, Italy
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1 | 2019年 / 68卷 / 01期
关键词
Computed tomography; K-edge imaging; Photon counting detectors; Energy resolution;
D O I
10.1007/978-981-10-9035-6_22
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray spectral computed microtomography (mu-CT) has gained considerable interest in recent years thanks to the development of Photon Counting X-ray Detectors (PCXDs). Through the energy-based discrimination of the photons, obtained by setting up the discriminator threshold at different levels, PCXDs allow measuring photon energies with an accuracy appropriate for several practical applications. The major potentials of this approach are multiple contrast images (sometimes referred to as "color" or "spectral" images), obtained by using a single polychromatic source. In contrast to multiple acquisitions with different tube spectra, photon-counting spectral CT eliminates the risk of misregistration due to motion between consecutive scans and it allows for the elimination of dark noise in the image by rejecting all the events below the signal threshold. Of particular importance is the application of spectral CT in preclinical models where small animals are scanned and an effective discrimination among e.g. soft-tissue, bone and K-edge contrast agents can be in principle performed in a single shot. While spectral CT is considered very promising, its practical application has been hampered by the charge sharing issue that negatively affects the energy resolution of PCXDs. However, latest generations of PCXDs implement solutions to cope with the charge sharing effects, thus allowing sharp color sensitivity. This work presents a comparison of K-edge spectral CT images acquired with the Pixirad-I/Pixie-III detector with and without the application of a charge sharing recovery solution. When a solution for the charge sharing issue is considered both the spatial accuracy and energy resolution are preserved, thus allowing accurate K-edge subtraction imaging.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 5 条
  • [1] Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging
    Ballabriga, R.
    Alozy, J.
    Campbell, M.
    Frojdh, E.
    Heijne, E. H. M.
    Koenig, T.
    Llopart, X.
    Marchal, J.
    Pennicard, D.
    Poikela, T.
    Tlustos, L.
    Valerio, P.
    Wong, W.
    Zuber, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [2] PIXIE III: a very large area photon-counting CMOS pixel ASIC for sharp X-ray spectral imaging
    Bellazzini, R.
    Brez, A.
    Spandre, G.
    Minuti, M.
    Pinchera, M.
    Delogu, P.
    de Ruvo, P. L.
    Vincenzi, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [3] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [4] Spectral and dual-energy X-ray imaging for medical applications
    Fredenberg, Erik
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 74 - 87
  • [5] Study of charge-sharing in MEDIPIX3 using a micro-focused synchrotron beam
    Gimenez, E. N.
    Ballabriga, R.
    Campbell, M.
    Horswell, I.
    Llopart, X.
    Marchal, J.
    Sawhney, K. J. S.
    Tartoni, N.
    Turecek, D.
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6