Heat transfer measurement in a three-phase spray column direct contact heat exchanger for utilisation in energy recovery from low-grade sources

被引:25
|
作者
Baqir, Ali Sh. [1 ]
Mahood, Hameed B. [2 ]
Hameed, Mudher S. [2 ]
Campbell, Alasdair N. [3 ]
机构
[1] Al Furat Al Awsat Tech Univ, Al Najaf Engn Tech Coll, Dept Aeronaut Engn, Al Najaf, Iran
[2] Univ Misan, Misan, Iraq
[3] Univ Surrey, Dept Chem & Proc Engn, Guildford, Surrey, England
关键词
Spray column three-phase direct contact heat exchanger; Local volumetric heat transfer coefficient; Active height; Sparger configuration; TRANSFER COEFFICIENT; IMMISCIBLE LIQUID; N-PENTANE; CONDENSER; PREDICTION; PHASE; WATER; MODEL; VAPORIZATION; TEMPERATURE;
D O I
10.1016/j.enconman.2016.08.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy recovery from low-grade energy resources requires an efficient thermal conversion system to be economically viable. The use of a liquid-liquid-vapour direct contact heat exchanger in such processes could be suitable due to their high thermal efficiency and low cost in comparison to a surface type heat exchanger. In this paper, the local volumetric heat transfer coefficient (U-v) and the active height (H-v) of a spray column three-phase direct contact heat exchanger (evaporator) have been investigated experimentally. The heat exchanger comprised a cylindrical Perspex tube of 100 cm height and 10 cm diameter. Liquid pentane at its saturation temperature and warm water at 45 degrees C were used as the dispersed phase and the continuous phase respectively. Three different dispersed phase flow rates (10, 15 and 20 L/h) and four different continuous phase flow rates (10, 20, 30 and 40 L/h) were used throughout the experiments. In addition, three different sparger configurations (7, 19 and 36 nozzles) with two different nozzle diameters (1 and 1.25 mm) were tested. The results showed that the local volumetric heat transfer coefficient (U-v) along the column decreases with height. An increase in both the continuous and dispersed phase flow rates had a positive effect on U-v, while an increase in the number of nozzles in the sparger caused U-v to decrease. The active height was significantly affected by the dispersed and continuous phase flow rates, the sparger configuration and the temperature driving force in terms of the Jacob number. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:342 / 351
页数:10
相关论文
共 12 条
  • [1] Heat transfer efficiency and capital cost evaluation of a three-phase direct contact heat exchanger for the utilisation of low-grade energy sources
    Mahood, Hameed B.
    Campbell, Alasdair N.
    Thorpe, Rex B.
    Sharif, Adel O.
    ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 101 - 109
  • [2] Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger
    Mahood, Hameed B.
    Campbell, A. N.
    Baqir, Ali Sh.
    Sharif, A. O.
    Thorpe, R. B.
    HEAT AND MASS TRANSFER, 2018, 54 (06) : 1697 - 1705
  • [3] Heat transfer measurement in a three-phase direct-contact condenser under flooding conditions
    Mahood, Hameed B.
    Campbell, A. N.
    Sharif, A. O.
    Thorpe, R. B.
    APPLIED THERMAL ENGINEERING, 2016, 95 : 106 - 114
  • [4] Measuring the Overall Volumetric Heat Transfer Coefficient in a Vapor-Liquid-Liquid Three-Phase Direct Contact Heat Exchanger
    Mahood, Hameed B.
    Campbell, Alasdair N.
    Thorpe, Rex B.
    Sharif, Adel O.
    HEAT TRANSFER ENGINEERING, 2018, 39 (03) : 208 - 216
  • [5] Transient volumetric heat transfer coefficient prediction of a three-phase direct contact condenser
    Mahood, Hameed B.
    Sharif, Adel O.
    Thorpe, Rex B.
    HEAT AND MASS TRANSFER, 2015, 51 (02) : 165 - 170
  • [6] Development of a direct contact heat exchanger for energy and water recovery from humid flue gas
    Cui, Zhaoyang
    Du, Qian
    Gao, Jianmin
    Bie, Rushan
    Li, Dun
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [7] Experimental measurements and theoretical prediction for the volumetric heat transfer coefficient of a three-phase direct contact condenser
    Mahood, Hameed B.
    Campbell, Alasdair N.
    Thorpe, Rex. B.
    Sharif, Ade O.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2015, 66 : 180 - 188
  • [8] Growth of Two-Phase Bubble-Drop in a Three-Phase Direct-Contact Heat Transfer System: Experimental Study
    Kareem, Ahmed R.
    Mahood, Hameed B.
    Baqir, Ali Sh.
    HEAT TRANSFER, 2025,
  • [9] Heat transfer characteristics of a thermoelectric power generator system for low-grade waste heat recovery from the sugar industry
    Punin, Weera
    Maneewan, Somchai
    Punlek, Chantana
    HEAT AND MASS TRANSFER, 2019, 55 (04) : 979 - 991
  • [10] HEAT TRANSFER MODELLING OF TWO-PHASE BUBBLES SWARM CONDENSING IN THREE-PHASE DIRECT-CONTACT CONDENSER
    Mahood, Hameed B.
    Sharif, Adel O.
    Al-Ailbi, Sami
    Hossini, Sayid Ali
    Thorpe, Rex B.
    THERMAL SCIENCE, 2016, 20 (01): : 143 - 153