Complications after LP related to needle type: pencil-point versus Quincke

被引:12
作者
Aamodt, A [1 ]
Vedeler, C [1 ]
机构
[1] Univ Bergen, Haukeland Hosp, Dept Neurol, N-5021 Bergen, Norway
来源
ACTA NEUROLOGICA SCANDINAVICA | 2001年 / 103卷 / 06期
关键词
lumbar puncture; post-dural puncture headache; needle type;
D O I
10.1034/j.1600-0404.2001.103006396.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives - We studied the incidence of complications after diagnostic lumbar puncture (LP) related to needle type. Material ann methods - A 5 months' observational study of routine diagnostic LP in 83 patients was conducted. Results - Significantly more headache was observed after LP using thicker cutting needles (20G Quincke) compared with thinner cutting or non-cutting needles (22G Quincke or pencil-point). No significant difference in complications after LP was found between the 22G Quincke and pencil-point needles. Conclusion - The size of the needle and not the needle shape seems to be the main determinant for post-dural puncture headache (PDPH).