Correction of refractive distortion in whole-eye optical coherence tomography imaging of the mouse eye

被引:2
|
作者
Tan, Jinzhen [1 ]
Qiu, Rui [2 ]
Ding, Xueqing [2 ]
Dai, Cuixia [2 ]
Meng, Jing [1 ]
Zhao, Jingxiu [1 ]
Ma, Fei [1 ]
Qi, Sumin [1 ]
机构
[1] Qufu Normal Univ, Sch Comp, Rizhao 276826, Peoples R China
[2] Shanghai Inst Technol, Coll Sci, Shanghai 201418, Peoples R China
基金
中国国家自然科学基金;
关键词
Fermat's principle; light distortion correction; ophthalmic diagnosis; optical coherence tomography; CORNEAL THICKNESS; FORM-DEPRIVATION; ANTERIOR-SEGMENT; SCHEIMPFLUG; C57BL/6;
D O I
10.1002/jbio.202200146
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is an imaging modality that acquires high-resolution cross-sectional images of living tissues and it has become the standard in ophthalmological diagnoses. However, most quantitative morphological measurements are based on the raw OCT images which are distorted by several mechanisms such as the refraction of probe light in the sample and the scan geometries and thus the analysis of the raw OCT images inevitably induced calculation errors. In this paper, based on Fermat's principle and the concept of inverse light tracing, image distortions due to refraction occurred at tissue boundaries in the whole-eye OCT imaging of mouse by telecentric scanning were corrected. Specially, the mathematical correction models were deducted for each interface, and the high-precision whole-eye image was recovered segment by segment. We conducted phantom and in vivo experiments on mouse and human eyes to verify the distortion correction algorithm, and several parameters of the radius of curvature, thickness of tissues and error, were calculated to quantitatively evaluate the images. Experimental results demonstrated that the method can provide accurate and reliable measurements of whole-eye parameters and thus be a valuable tool for the research and clinical diagnosis.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Tissue Contrast Imaging of Anterior Eye Based on Optical Properties Measured by Polarization Sensitive Optical Coherence Tomography
    Miyazawa, A.
    Yamanari, M.
    Makita, S.
    Miura, M.
    Kawana, K.
    Lwaya, K.
    Goto, H.
    Oshika, T.
    Yasuno, Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [42] Refractive index correction in optical coherence tomography images of multilayer tissues
    Turani, Zahra
    Fatemizadeh, Emad
    Xu, Qiuyun
    Daveluy, Steven
    Mehregan, Darius
    Nasiriavanaki, Mohammadreza
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (07)
  • [43] Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase
    Asejczyk-Widlicka, Magdelena
    Schachar, Ronald A.
    Pierscionek, Barbara K.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (02)
  • [44] In Vivo Imaging of Mouse Cochlea by Optical Coherence Tomography
    Tona, Yosuke
    Sakamoto, Tatsunori
    Nakagawa, Takayuki
    Adachi, Tsunemichi
    Taniguchi, Mirei
    Torii, Hiroko
    Hamaguchi, Kiyomi
    Kitajiri, Shin-ichiro
    Ito, Juichi
    OTOLOGY & NEUROTOLOGY, 2014, 35 (02) : E84 - E89
  • [45] A model for screening eye diseases using optical coherence tomography images
    Gupta S.
    Chandra S.
    Maheswari N.
    Sivagami M.
    International Journal of Computers and Applications, 2022, 44 (04) : 396 - 400
  • [46] Pathogenesis of the dry eye syndrome observed by optical coherence tomography in vitro
    Kray, Oya
    Lenz, Markus
    Spoeler, Felix
    Kray, Stefan
    Kurz, Heinrich
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [47] Model eye tool for retinal optical coherence tomography instrument calibration
    Wang, Hongting
    Liu, Wenli
    Hu, Zhixiong
    Li, Xiuyu
    Li, Fei
    Duan, Liangcheng
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2021, 14 (03)
  • [48] Investigations of the eye fundus using a simultaneous optical coherence tomography/indocyanine green fluorescence imaging system
    Podoleanu, Adrian G.
    Dobre, George M.
    Cernat, Ramona
    Rogers, John A.
    Pedro, Justin
    Rosen, Richard B.
    Garcia, Patricia
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (01)
  • [49] Assessment of the posterior segment of the cat eye by optical coherence tomography (OCT)
    Gekeler, Florian
    Gmeiner, Helmut
    Voelker, Michael
    Sachs, Helmut
    Messias, Andre
    Eule, Corinna
    Bartz-Schmidt, Karl Ulrich
    Zrenner, Eberhart
    Shinoda, Kei
    VETERINARY OPHTHALMOLOGY, 2007, 10 (03) : 173 - 178
  • [50] Assessment of Full-Eye Response to Osmotic Stress in Mouse Model In Vivo Using Optical Coherence Tomography
    Ni, Yang
    Xu, Baisheng
    Wu, Lan
    Du, Chixin
    Jiang, Bo
    Ding, Zhihua
    Li, Peng
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015