Correction of refractive distortion in whole-eye optical coherence tomography imaging of the mouse eye

被引:2
|
作者
Tan, Jinzhen [1 ]
Qiu, Rui [2 ]
Ding, Xueqing [2 ]
Dai, Cuixia [2 ]
Meng, Jing [1 ]
Zhao, Jingxiu [1 ]
Ma, Fei [1 ]
Qi, Sumin [1 ]
机构
[1] Qufu Normal Univ, Sch Comp, Rizhao 276826, Peoples R China
[2] Shanghai Inst Technol, Coll Sci, Shanghai 201418, Peoples R China
基金
中国国家自然科学基金;
关键词
Fermat's principle; light distortion correction; ophthalmic diagnosis; optical coherence tomography; CORNEAL THICKNESS; FORM-DEPRIVATION; ANTERIOR-SEGMENT; SCHEIMPFLUG; C57BL/6;
D O I
10.1002/jbio.202200146
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is an imaging modality that acquires high-resolution cross-sectional images of living tissues and it has become the standard in ophthalmological diagnoses. However, most quantitative morphological measurements are based on the raw OCT images which are distorted by several mechanisms such as the refraction of probe light in the sample and the scan geometries and thus the analysis of the raw OCT images inevitably induced calculation errors. In this paper, based on Fermat's principle and the concept of inverse light tracing, image distortions due to refraction occurred at tissue boundaries in the whole-eye OCT imaging of mouse by telecentric scanning were corrected. Specially, the mathematical correction models were deducted for each interface, and the high-precision whole-eye image was recovered segment by segment. We conducted phantom and in vivo experiments on mouse and human eyes to verify the distortion correction algorithm, and several parameters of the radius of curvature, thickness of tissues and error, were calculated to quantitatively evaluate the images. Experimental results demonstrated that the method can provide accurate and reliable measurements of whole-eye parameters and thus be a valuable tool for the research and clinical diagnosis.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Optical coherence tomography of cornea and anterior segment of the eye
    Koop, N
    Brinkmann, R
    Lankenau, E
    Flache, S
    Engelhardt, R
    Birngruber, R
    OPHTHALMOLOGE, 1997, 94 (07): : 481 - 486
  • [22] Changes of the Anterior Eye Segment after Eye Muscle Surgery - Evaluation by Optical Coherence Tomography in Adults
    Luechtenberg, M.
    Haeussler-Sinangin, Y.
    Kohnen, T.
    Kuhli-Hattenbach, C.
    Koss, M. J.
    Schalnus, R.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (10) : 782 - 785
  • [23] Polarization sensitive optical coherence tomography in the human eye
    Pircher, Michael
    Hitzenberger, Christoph K.
    Schmidt-Erfurth, Ursula
    PROGRESS IN RETINAL AND EYE RESEARCH, 2011, 30 (06) : 431 - 451
  • [24] Anterior segment optical coherence tomography in eye injuries
    Edward Wylegala
    Dariusz Dobrowolski
    Anna Nowińska
    Dorota Tarnawska
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 451 - 455
  • [25] Corneal Responses to Eye Rubbing with Spectral Domain Optical Coherence Tomography
    Prakasam, Ruby K.
    Schwiede, Mario
    Huetz, Werner W.
    Guthoff, Rudolf F.
    Stachs, Oliver
    CURRENT EYE RESEARCH, 2012, 37 (01) : 25 - 32
  • [26] Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging
    Corcoran, Anthony
    Muyo, Gonzalo
    van Hemert, Jano
    Gorman, Alistair
    Harvey, Andrew R.
    JOURNAL OF MODERN OPTICS, 2015, 62 (21) : 1828 - 1838
  • [27] Progress on Developing Adaptive Optics-Optical Coherence Tomography for In Vivo Retinal Imaging: Monitoring and Correction of Eye Motion Artifacts
    Zawadzki, Robert J.
    Capps, Arlie G.
    Kim, Dae Yu
    Panorgias, Athanasios
    Stevenson, Scott B.
    Hamann, Bernd
    Werner, John S.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2014, 20 (02)
  • [28] Development of a Widefield Phantom Eye for Retinal Optical Coherence Tomography
    Corcoran, Anthony T.
    Muyo, Gonzalo
    van Hemert, Jano I.
    Harvey, Andrew R.
    DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE VI, 2014, 8945
  • [29] Combination of Optical Coherence Tomography and Reflectometry Technique for Eye Measurement
    Lu, Hui
    Wang, Michael R.
    OPHTHALMIC TECHNOLOGIES XXIII, 2013, 8567
  • [30] Optical coherence tomography of the Tokay gecko (Gekko gecko) eye
    Go, Seokmin
    Kang, Seonmi
    Kwon, Jun
    Park, Sechang
    Seo, Kangmoon
    VETERINARY OPHTHALMOLOGY, 2020, 23 (05) : 863 - 871