Correction of refractive distortion in whole-eye optical coherence tomography imaging of the mouse eye

被引:2
|
作者
Tan, Jinzhen [1 ]
Qiu, Rui [2 ]
Ding, Xueqing [2 ]
Dai, Cuixia [2 ]
Meng, Jing [1 ]
Zhao, Jingxiu [1 ]
Ma, Fei [1 ]
Qi, Sumin [1 ]
机构
[1] Qufu Normal Univ, Sch Comp, Rizhao 276826, Peoples R China
[2] Shanghai Inst Technol, Coll Sci, Shanghai 201418, Peoples R China
基金
中国国家自然科学基金;
关键词
Fermat's principle; light distortion correction; ophthalmic diagnosis; optical coherence tomography; CORNEAL THICKNESS; FORM-DEPRIVATION; ANTERIOR-SEGMENT; SCHEIMPFLUG; C57BL/6;
D O I
10.1002/jbio.202200146
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is an imaging modality that acquires high-resolution cross-sectional images of living tissues and it has become the standard in ophthalmological diagnoses. However, most quantitative morphological measurements are based on the raw OCT images which are distorted by several mechanisms such as the refraction of probe light in the sample and the scan geometries and thus the analysis of the raw OCT images inevitably induced calculation errors. In this paper, based on Fermat's principle and the concept of inverse light tracing, image distortions due to refraction occurred at tissue boundaries in the whole-eye OCT imaging of mouse by telecentric scanning were corrected. Specially, the mathematical correction models were deducted for each interface, and the high-precision whole-eye image was recovered segment by segment. We conducted phantom and in vivo experiments on mouse and human eyes to verify the distortion correction algorithm, and several parameters of the radius of curvature, thickness of tissues and error, were calculated to quantitatively evaluate the images. Experimental results demonstrated that the method can provide accurate and reliable measurements of whole-eye parameters and thus be a valuable tool for the research and clinical diagnosis.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Advances in Whole-Eye Optical Coherence Tomography Imaging
    Kuo, Anthony N.
    McNabb, Ryan P.
    Izatt, Joseph A.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (02): : 99 - 104
  • [2] Optical coherence tomography for whole eye segment imaging
    Dai, Cuixia
    Zhou, Chuanqing
    Fan, Shanhui
    Chen, Zhe
    Chai, Xinyu
    Ren, Qiushi
    Jiao, Shuliang
    OPTICS EXPRESS, 2012, 20 (06): : 6109 - 6115
  • [3] Full ocular biometry through dual-depth whole-eye optical coherence tomography
    Kim, Hyung-Jin
    Kim, Minji
    Hyeon, Min Gyu
    Choi, Youngwoon
    Kimi, Beop-Min
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (02): : 360 - 372
  • [4] Whole-Eye OCT Imaging of Refractive Errors in Genetically Modified Zebrafish
    Sabour, Shiva
    Brown-Panton, Cherie A.
    Kotova, Anna
    Zoidl, Georg S. O.
    Zoidl, Christiane
    Zoidl, Georg R.
    Tabatabaei, Nima
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVIII, 2024, 12830
  • [5] High-resolution, dual-depth spectral-domain optical coherence tomography with interlaced detection for whole-eye imaging
    Kim, Hyung-Jin
    Kim, Pil Un
    Hyeon, Min Gyu
    Choi, Youngwoon
    Kim, Jeehyun
    Kim, Beop-Min
    APPLIED OPTICS, 2016, 55 (26) : 7212 - 7217
  • [6] Polarization-sensitive optical coherence tomography imaging of the anterior mouse eye
    Baumann, Bernhard
    Augustin, Marco
    Lichtenegger, Antonia
    Harper, Danielle J.
    Muck, Martina
    Eugui, Pablo
    Wartak, Andreas
    Pircher, Michael
    Hitzenberger, Christoph K.
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (08)
  • [7] Dual band dual focus optical coherence tomography for imaging the whole eye segment
    Fan, Shanhui
    Li, Lin
    Li, Qian
    Dai, Cuixia
    Ren, Qiushi
    Jiao, Shuliang
    Zhou, Chuanqing
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (07): : 2481 - 2493
  • [8] Cross-scanning optical coherence tomography angiography for eye motion correction
    Kim, Hyung-Jin
    Song, Byeong Joo
    Choi, Youngwoon
    Kim, Beop-Min
    JOURNAL OF BIOPHOTONICS, 2020, 13 (09)
  • [9] Imaging of eye tumor in the mouse model of retinoblastoma with spectral-domain optical coherence tomography
    Jiao, Shuliang
    Ruggeri, Marco
    Wehbe, Hassan
    Gregory, Giovanni
    Jockovich, Maria E.
    Hackam, Abigail
    Puliafito, Carmen A.
    OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [10] Dual channel dual focus optical coherence tomography for imaging accommodation of the eye
    Zhou, Chuanqing
    Wang, Jianhua
    Jiao, Shuliang
    OPTICS EXPRESS, 2009, 17 (11): : 8947 - 8955