Visual performance following implantation of presbyopia correcting intraocular lenses

被引:9
作者
Torky, Magda A. [1 ]
El Nokrashy, Amgad [1 ]
Metwally, Heba [2 ]
Abdelhameed, Ameera G. [1 ]
机构
[1] Mansoura Univ, Fac Med, Mansoura Ophthalm Ctr, Dept Ophthalmol, Mansoura, Egypt
[2] Mem Inst Ophthalm Res, Mansoura, Egypt
关键词
EXTENDED-DEPTH; BILATERAL IMPLANTATION; CONTRAST SENSITIVITY; CLINICAL-OUTCOMES; TRIFOCAL IOL; VISION; RANGE; QUALITY; CATARACT; ACUITY;
D O I
10.1038/s41433-022-02188-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To compare the visual outcomes following bilateral implantation of 3 presbyopia correcting IOLs. Methods Results are reported for patients who underwent phacoemulsification with bilateral implantation of one of the following IOLs: Panoptix IOL, AT LISA tri IOL and Symphony IOL. Six months postoperative examination included monocular UIVA at 80 and 60 cm and monocular UNVA and DCNVA at 40 cm, monocular UDVA and CDVA, Spherical equivalent (SE) refraction, binocular defocus curve, contrast sensitivity, photopic phenomena, and spectacle independence. Results UIVA at 80 cm was significantly better in the AT LISA group and the Symfony groups than the Panoptix group, while UIVA at 60 cm was better in the Symfony group and the Panoptix group than the AT LISA group. A worse DCNVA was recorded in the Symfony group. At a defocus of -2.50 D, the near VA was similar in the PanOptix and AT LISA groups (0.05, 0.07 logMAR respectively), which were significantly better than the Symfony group (0.3 LogMAR). Binocular photopic and scotopic contrast sensitivity outcomes were similar among the three groups at all spatial frequencies. In Symphony group, the frequency and the degree of bother of photic phenomena was relatively higher than the other two groups. Higher percentage of patients in symphony group reported their need for reading glasses. Conclusion PanOptix IOL and AT LISA IOL would be a good choice for patients aiming for an optimum near vision, while Symfony IOL seems suitable for patients having the priority for good intermediate vision.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 50 条
  • [41] Risk factors in self-reported dissatisfied patients implanted with various presbyopia-correcting intraocular lenses after cataract surgery
    Jeon, Woosung
    Yoon, Chang Ho
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [42] The role of presbyopia-correcting intraocular lenses after laser in situ keratomileusis
    Khor, Wei Boon
    Afshari, Natalie A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (01) : 35 - 40
  • [43] Preoperative Factors Affecting Visual Acuity Following the Implantation of Diffractive Multifocal Intraocular Lenses
    Takabatake, Ryu
    Takahashi, Makiko
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (10) : 674 - +
  • [44] Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopia
    Zamora-de La Cruz, Diego
    Zuniga-Posselt, Karla
    Bartlett, John
    Gutierrez, Mario
    Abariga, Samuel A.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2020, (06):
  • [45] Visual and optical performance with hybrid multifocal intraocular lenses
    Madrid-Costa, David
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2010, 93 (06) : 426 - 440
  • [46] Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system
    Kim, Myoung Joon
    Zheleznyak, Len
    MacRae, Scott
    Tchah, Hungwon
    Yoon, Geunyoung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) : 1305 - 1312
  • [47] Multifocal and Accommodating Intraocular Lenses for the Treatment of Presbyopia A Report by the American Academy of Ophthalmology
    Schallhorn, Julie M.
    Pantanelli, Seth M.
    Lin, Charles C.
    Al-Mohtaseb, Zaina N.
    Steigleman, Walter Allan, III
    Santhiago, Marcony R.
    Olsen, Timothy W.
    Kim, Stephen J.
    Waite, Aaron M.
    Rose-Nussbaumer, Jennifer R.
    OPHTHALMOLOGY, 2021, 128 (10) : 1469 - 1482
  • [48] Comparison of Five Presbyopia-Correcting Intraocular Lenses: Optical-Bench Assessment with Visual-Quality Simulation
    Labuz, Grzegorz
    Yan, Weijia
    Baur, Isabella D. D.
    Khoramnia, Ramin
    Auffarth, Gerd U. U.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [49] Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics
    Novacek, Ladislav Viktor
    Nemcova, Marie
    Tyx, Katerina
    Lahodova, Kristyna
    Rejmont, Leos
    Rozsival, Pavel
    Studeny, Pavel
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [50] Perceptual cost and benefit of presbyopia-correcting intraocular lenses: effect of energy balance, addition, and adaptation
    Esteban-ibanez, Eduardo
    Gambra, Enrique
    Marrakchi, Yassine
    Sawides, Lucie
    Dorronsoro, Carlos
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 849 - 871