Grid Harmonic Current Correction Based on Parallel Three-Phase Shunt Active Power Filter

被引:21
作者
De souza, Laysa L. [1 ]
Rocha, Nady [1 ]
Fernandes, Darlan A. [1 ]
De Sousa, Reuben P. R. [2 ]
Jacobina, Cursino B. [2 ]
机构
[1] Univ Fed Paraiba, Dept Elect Engn, BR-58051900 Joao Pessoa, Paraiba, Brazil
[2] Univ Fed Campina Grande, BR-58428830 Campina Grande, Paraiba, Brazil
关键词
Inverters; Topology; Harmonic analysis; Harmonic distortion; Power harmonic filters; Switches; Reactive power; Cost function; FS-MPC; parallel connected inverters; shunt active power filter (SAPF); MODEL-PREDICTIVE CONTROL; CONTROL STRATEGY; CONVERTER;
D O I
10.1109/TPEL.2021.3107399
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a finite-set model predictive control (FS-MPC) applied to the shunt active power filters (SAPF) based on three-phase inverters connected in parallel sharing the same dc-link. The discrete-time model of the system is used to predict the future value of the grid, circulation, and offset currents. The presence of circulation and offset currents occurs due to the connection of the two inverters in parallel sharing the same dc-link. There are 64 switching state vectors for SAPF and, in order to reduce the burden of calculation, only 30 switching states are chosen and applied, however keeping the advantages of the FS-MPC algorithm. The control strategy ensures the sinusoidal shape of the grid current, high power factor, and circulating and offset currents suppression. The FS-MPC has its performance compared to the pulsewidth modulation (PWM) strategy considering the SAPF with two parallel inverters, the conventional SAPF and the neutral-point-clamped SAPF. These comparisons include harmonic distortion, power semiconductor losses, and analysis of dc-link capacitor losses. As a multilevel topology, the SAPF with two parallel inverters using FS-MPC present competitive efficiency and can be applied with a good performance in industrial and residential applications. Simulation results and a laboratory-scale experimental platform is used for corroborating the proposal.
引用
收藏
页码:1422 / 1434
页数:13
相关论文
共 50 条
  • [41] Fuzzy Logic Controller Based Three-Phase Shunt Active Power Filter for Compensating Harmonics and Reactive Power under Unbalanced Mains Voltages
    Belaidi, R.
    Haddouche, A.
    Guendouz, H.
    TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 : 560 - 570
  • [42] Analysis of the grid side behavior of a LCL-filter based three-phase active rectifier
    Blaabjerg, F
    Chiarantoni, E
    Dell'Aquila, A
    Liserre, M
    Vergura, S
    2003 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 2003, : 775 - 780
  • [43] Model reference generating an optimal DC bus voltage level for a three-phase shunt active power filter
    Rahmani, S
    Al-Haddad, K
    Fnaiech, F
    2004 11TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, 2004, : 22 - 27
  • [44] Implementation of Three-Phase Active Filter for Compensation of Harmonics and Displacement with Phases Current Balancing
    Demonti, Rogers
    Bianchin, Carlos G.
    Omori, Julio S.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5, 2008, : 30 - 35
  • [45] Discrete Polynomial Current Controller for a Three-Phase VSC Connected to the Grid using a LCL Filter
    Ramos, Carlos
    Martins, Antonio
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 1702 - 1708
  • [46] Three-Phase Transformerless PV Inverter With Reconfigurable LCL Filter and Reactive Power Capability
    Dadkhah, Jalal
    Ho, Carl Ngai Man
    Siu, Ken King-Man
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (07) : 8229 - 8241
  • [47] Direct Power Control Concept and Analysis for Three Phase Shunt Active Power Filter
    Chaoui, Abdelmadjid
    Gaubert, Jean-Paul
    Bouafia, Abdelouahab
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 1286 - 1294
  • [48] DC-Link Capacitor Voltage Regulation for Three-Phase Three-Level Inverter-Based Shunt Active Power Filter with Inverted Error Deviation Control
    Hoon, Yap
    Radzi, Mohd Amran Mohd
    Hassan, Mohd Khair
    Mailah, Nashiren Farzilah
    ENERGIES, 2016, 9 (07)
  • [49] Power quality improvement of three-phase electrical systems using active-passive hybrid harmonic filter
    Nor, Khairul Anuar Mohd
    Abdullah, Noramalina
    RESULTS IN ENGINEERING, 2024, 22
  • [50] System integrated active power filter for three-phase rectifier application
    Yang, Han
    Khan, Muhammad Mansoor
    Chen, Chen
    POWERENG2007: INTERNATIONAL CONFERENCE ON POWER ENGINEERING - ENERGY AND ELECTRICAL DRIVES PROCEEDINGS, VOLS 1 & 2, 2007, : 29 - 34