Grid Harmonic Current Correction Based on Parallel Three-Phase Shunt Active Power Filter

被引:21
作者
De souza, Laysa L. [1 ]
Rocha, Nady [1 ]
Fernandes, Darlan A. [1 ]
De Sousa, Reuben P. R. [2 ]
Jacobina, Cursino B. [2 ]
机构
[1] Univ Fed Paraiba, Dept Elect Engn, BR-58051900 Joao Pessoa, Paraiba, Brazil
[2] Univ Fed Campina Grande, BR-58428830 Campina Grande, Paraiba, Brazil
关键词
Inverters; Topology; Harmonic analysis; Harmonic distortion; Power harmonic filters; Switches; Reactive power; Cost function; FS-MPC; parallel connected inverters; shunt active power filter (SAPF); MODEL-PREDICTIVE CONTROL; CONTROL STRATEGY; CONVERTER;
D O I
10.1109/TPEL.2021.3107399
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a finite-set model predictive control (FS-MPC) applied to the shunt active power filters (SAPF) based on three-phase inverters connected in parallel sharing the same dc-link. The discrete-time model of the system is used to predict the future value of the grid, circulation, and offset currents. The presence of circulation and offset currents occurs due to the connection of the two inverters in parallel sharing the same dc-link. There are 64 switching state vectors for SAPF and, in order to reduce the burden of calculation, only 30 switching states are chosen and applied, however keeping the advantages of the FS-MPC algorithm. The control strategy ensures the sinusoidal shape of the grid current, high power factor, and circulating and offset currents suppression. The FS-MPC has its performance compared to the pulsewidth modulation (PWM) strategy considering the SAPF with two parallel inverters, the conventional SAPF and the neutral-point-clamped SAPF. These comparisons include harmonic distortion, power semiconductor losses, and analysis of dc-link capacitor losses. As a multilevel topology, the SAPF with two parallel inverters using FS-MPC present competitive efficiency and can be applied with a good performance in industrial and residential applications. Simulation results and a laboratory-scale experimental platform is used for corroborating the proposal.
引用
收藏
页码:1422 / 1434
页数:13
相关论文
共 50 条
  • [31] Shunt Active Filter with Optimum Reference Generation Algorithm for Power Factor and Harmonic Current Compensation
    Hoffmann, Nils
    Asiminoaei, Lucian
    Hansen, Steffan
    Fuchs, Friedrich W.
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 3044 - +
  • [32] Model Predictive Current Control for Low-Cost Shunt Active Power Filter
    Abdel-Aziz, Ali A.
    Elgenedy, Mohamed A.
    Williams, Barry W.
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2024, 10 (04): : 1589 - 1598
  • [33] A Cascaded Controller for a Grid-Tied Photovoltaic System With Three-Phase Half-Bridge Interleaved Buck Shunt Active Power Filter: Hybrid Control Strategy and Fuzzy Logic Approach
    Echalih, Salwa
    Abouloifa, Abdelmajid
    Lachkar, Ibtissam
    El Aroudi, Abdelali
    Hekss, Zineb
    Giri, Fouad
    Al-Numay, Mohammed S.
    IEEE JOURNAL ON EMERGING AND SELECTED TOPICS IN CIRCUITS AND SYSTEMS, 2022, 12 (01) : 320 - 330
  • [34] Solar Photovoltaic System Interfaced Shunt Active Power Filter for Enhancement of Power Quality in Three-Phase Distribution System
    Senguttuvan, S.
    Vijayakumar, M.
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2018, 27 (11)
  • [35] Magnetic saturation impact on three-phase shunt active power filters
    Chihab A.A.
    Ouadi H.
    Renewable Energy and Power Quality Journal, 2020, 18 : 539 - 544
  • [36] Novel circuit topology for three-phase active power filter
    Wu, Jinn-Chang
    Jou, Hurng-Liahng
    Feng, Ya-Tsung
    Hsu, Wen-Pin
    Huang, Min-Sheng
    Hou, Wen-Jet
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 444 - 449
  • [37] Grid Impedance Detection Based On Complex Coefficient Filter and Full-order Capacitor Current Observer for Three-phase Grid-connected Inverters
    Wang, Kaixin
    Yang, Yong
    Fan, Mingdi
    Tang, Yuhang
    Li, Haoyang
    Chen, Rong
    Hu, Jiefeng
    Zeng, Weibo
    Rodriguez, Jose
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 2408 - 2420
  • [38] Variable parameter pulse width modulation-based current tracking technology applied to four-switch three-phase shunt active power filter
    Tan, Xingguo
    Li, Qingmin
    Wang, Hui
    Cao, Lei
    Han, Shuai
    IET POWER ELECTRONICS, 2013, 6 (03) : 543 - 553
  • [39] Current Harmonic Compensation by a Single-Phase Shunt Active Power Filter Controlled by Adaptive Neural Filtering
    Cirrincione, Maurizio
    Pucci, Marcello
    Vitale, Gianpaolo
    Miraoui, Abdellatif
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (08) : 3128 - 3143
  • [40] A Novel Frequency Locked Loop With Current Harmonic Elimination Method for the Three-Phase Grid-Connected Inverter
    Uzzaman, Tawfique
    Kim, Unghoe
    Choi, Woojin
    IEEE ACCESS, 2022, 10 : 32870 - 32878