Aerosol delivery and modern mechanical ventilation -: In vitro/in vivo evaluation

被引:156
作者
Miller, DD
Amin, MM
Palmer, LB
Shah, AR
Smaldone, GC
机构
[1] SUNY Stony Brook, Hlth Sci Ctr 040, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Div Pulm & Critical Care Med, Dept Med, Stony Brook, NY 11794 USA
[3] Univ Hosp, Dept Resp Care, Stony Brook, NY USA
关键词
aerosolized antibiotics; nebulizers; bronchodilators; humidification; sputum;
D O I
10.1164/rccm.200210-1167OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aerosol delivery via a mechanical ventilator remains unregulated with no standards for drug delivery to intubated patients. Bench models predicting drug delivery have not been validated in vivo. For modern ventilator designs, we chose to identify, on the bench, the most important variables affecting aerosol delivery and to correlate in vitro predictions of aerosol delivery with in vivo end points independent of patient response. Test aerosols of albuterol and antibiotics were compared. Bench measurements of inhaled mass (percentage of nebulizer charge, mean +/- SEM) ranged from 5.7 +/- 0.5% to 37.4 +/- 1.6%, with breath-actuated nebulization and humidity identified as the most important factors determining aerosol delivery. In patients, sputum levels of deposited antibiotics varied from 1.10 to 19.6 mug/ ml/mg. Variation in sputum levels correlated with predictions from the in vitro model. Aerosol delivery in. ventilated patients can be efficient and reproducible only if defined ventilator parameters are tightly controlled. Key parameters can be determined via in vitro bench testing defining delivery standards for clinical trials of drugs with narrow therapeutic/toxicity ratios.
引用
收藏
页码:1205 / 1209
页数:5
相关论文
共 16 条
  • [11] NEBULIZER FUNCTION DURING MECHANICAL VENTILATION
    ORIORDAN, TG
    GRECO, MJ
    PERRY, RJ
    SMALDONE, GC
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (05): : 1117 - 1122
  • [12] ORIORDAN TG, 1994, AM J RESP CRIT CARE, V150, P1474
  • [13] TRACHEAL ASPIRATES IN LONG-TERM MECHANICALLY VENTILATED PATIENTS - A HUMAN-MODEL OF GRAM-NEGATIVE INFECTION AND AIRWAY INFLAMMATION
    PALMER, LB
    SMALDONE, GC
    SIMON, S
    ORIORDAN, T
    MORRA, L
    [J]. CHEST, 1995, 108 (05) : 1326 - 1332
  • [14] Aerosolized antibiotics in mechanically ventilated patients: Delivery and response
    Palmer, LB
    Smaldone, GC
    Simon, SR
    O'Riordan, TG
    Cuccia, A
    [J]. CRITICAL CARE MEDICINE, 1998, 26 (01) : 31 - 39
  • [15] SMALDONE GC, 2000, EUR RESPIR J, V16, pS540
  • [16] PULMONARY DEPOSITION OF A NEBULIZED AEROSOL DURING MECHANICAL VENTILATION
    THOMAS, SHL
    ODOHERTY, MJ
    FIDLER, HM
    PAGE, CJ
    TREACHER, DF
    NUNAN, TO
    [J]. THORAX, 1993, 48 (02) : 154 - 159