Value of Contrast-Enhanced Ultrasound and Acoustic Radiation Force Impulse Imaging for the Differential Diagnosis of Benign and Malignant Thyroid Nodules

被引:15
作者
He, Yan [1 ]
Wang, Xiao Yan [1 ]
Hu, Qiao [1 ]
Chen, Xue Xue [1 ]
Ling, Bing [1 ]
Wei, Hai Ming [2 ]
机构
[1] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Ultrasound, Nanning, Peoples R China
[2] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Pathol, Nanning, Peoples R China
来源
FRONTIERS IN PHARMACOLOGY | 2018年 / 9卷
基金
中国国家自然科学基金;
关键词
thyroid nodule; contrast-enhanced ultrasound; acoustic radiation force impulse-imaging; shear wave velocity; receiver operating characteristic curve; ULTRASONOGRAPHIC TISSUE QUANTIFICATION; IN-VIVO; ELASTOGRAPHY; UTILITY; PHANTOM;
D O I
10.3389/fphar.2018.01363
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: To assess the value of contrast-enhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) imaging for the differential diagnosis of benign and malignant thyroid nodules. Methods: CEUS was performed in eighty-eight thyroid nodules. The patterns of CEUS were analyzed, and ARFI was then performed. The shear wave velocities (SWVs) of the nodules and the surrounding normal thyroid tissue were obtained. The areas under the curve (AUCs) and cut-off value were obtained by a receiver operating characteristic (ROC) curve analysis. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic rate of each modality were assessed and compared using pathological diagnosis. Results: Among 88 nodules, 29 nodules were malignant and 59 were benign. The sensitivity, specificity, PPV, NPV, and diagnostic rate of CEUS were 79.3, 91.5, 82.1, 90, and 87.5%, respectively. Using a cut-off value of 2.565 m/s for SWV, the sensitivity, specificity, PPV, NPV and diagnostic rate for malignancy were 75.9, 94.9, 88.0, 88.9, and 88.6%, respectively. The AUC was 0.878. The sensitivity, specificity, PPV, NPV and diagnostic rate of CEUS in combination with ARFI were 93.1, 89.8, 81.8, 96.3, and 90.9%, respectively. Conclusion: Both CEUS and ARFI are valuable for the differential diagnosis of benign and malignant thyroid nodules. Combining these two methods can improve the diagnostic rate.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Combination of conventional ultrasound and tissue quantification using acoustic radiation force impulse technology for differential diagnosis of small thyroid nodules
    Xing, Ping
    Chen, Qi
    Yang, Zhuo-Wen
    Liu, Chun-Bo
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (05): : 8288 - 8295
  • [22] Value of ultrasound elastography combined with contrast-enhanced ultrasound and micro-flow imaging in differential diagnosis of benign and malignant breast lesions
    Ding, Zuopeng
    Liu, Weiyong
    He, Nianan
    Ma, Xiaopeng
    Fu, Lili
    Ye, Lei
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (12): : 13941 - 13949
  • [23] Role of Ultrasound Elastography and Contrast-Enhanced Ultrasound (CEUS) in Diagnosis and Management of Malignant Thyroid Nodules-An Update
    Solomon, Carolina
    Petea-Balea, Diana-Raluca
    Dudea, Sorin Marian
    Bene, Ioana
    Silaghi, Cristina Alina
    Lenghel, Manuela Lavinia
    DIAGNOSTICS, 2025, 15 (05)
  • [24] ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY IN THE DIAGNOSIS OF THYROID NODULES: USEFUL OR NOT USEFUL?
    Zhang, Yi-Feng
    Xu, Hui-Xiong
    Xu, Jun-Mei
    Liu, Chang
    Guo, Le-Hang
    Liu, Lin-Na
    Zhang, Jing
    Xu, Xiao-Hong
    Qu, Shen
    Xing, Mingzhao
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (10) : 2581 - 2593
  • [25] Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification
    Jiang, Jue
    Shang, Xu
    Wang, Hua
    Xu, Yong-Bo
    Gao, Ya
    Zhou, Qi
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2015, 31 (03) : 138 - 144
  • [26] SONOGRAPHIC CHARACTERISTICS OF PAPILLARY THYROID CARCINOMA WITH COEXISTENT HASHIMOTO'S THYROIDITIS: CONVENTIONAL ULTRASOUND, ACOUSTIC RADIATION FORCE IMPULSE IMAGING AND CONTRAST-ENHANCED ULTRASOUND
    Peng, Qinghai
    Niu, Chengcheng
    Zhang, Meixiang
    Peng, Qiang
    Chen, Sijie
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02) : 471 - 480
  • [27] Clinical efficacy of novel elastography using acoustic radiation force impulse (ARFI) for diagnosis of malignant thyroid nodules
    Fukuhara, Takahiro
    Matsuda, Eriko
    Donishi, Ryohei
    Koyama, Satoshi
    Miyake, Naritomo
    Fujiwara, Kazunori
    Takeuchi, Hiromi
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2018, 3 (04): : 319 - 325
  • [28] Diagnostic value of "absent" pattern in contrast-enhanced ultrasound for the differentiation of thyroid nodules
    Wu, Qiong
    Li, Yi
    Wang, Yan
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 63 (04) : 325 - 334
  • [29] Application of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Benign and Malignant Subpleural Pulmonary Lesions
    Shen, MengJun
    Bi, Ke
    Cong, Yang
    Chen, HongWei
    Zhang, Yi
    Zhu, HuiMing
    Wang, Yin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1147 - 1157
  • [30] Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement
    Wu, Qiong
    Wang, Yan
    Li, Yi
    Hu, Bing
    He, Zhi-Yan
    ENDOCRINE, 2016, 53 (02) : 480 - 488