Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma mass spectrometry using a manometer-sized alumina packed micro-column

被引:189
|
作者
Yin, J [1 ]
Jiang, ZC [1 ]
Chang, G [1 ]
Hu, B [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
nanometer-sized alumina; flow injection; on-line preconcentration; ICP-MS; metal ions; environmental samples;
D O I
10.1016/j.aca.2005.03.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (Fl) on-line preconcentration procedure by using a manometer-sized alumina packed micro-column coupled to inductively coupled plasma mass spectrometry (ICP-MS) was described for simultaneous determination of trace metals (V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb) in the environmental samples. The effects of pH value, sample flow rate, preconcentration time, and interfering ions on the preconcentration of analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the manometer-sized alumina for V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb were found to be 11.7, 13.6, 15.7, 9.5, 12.2, 13.3, 17.1, 17.7 and 17.5 mg g(-1), respectively. With 60s preconcentration time and 60s elution time, an enrichment factor of 5 and the sampling frequency of 15 h(-1) were obtained. The proposed method has been applied to the determination of trace metals in environmental certified reference materials and natural water samples with satisfactory results. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
  • [21] Determination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column
    Anthemidis, Aristidis N.
    Martavaltzoglou, Evdoxia K.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 413 - 418
  • [22] Determination of trace amounts of zinc in water samples by flow injection isotope dilution inductively coupled plasma mass spectrometry
    Hwang, TJ
    Jiang, SJ
    ANALYST, 1997, 122 (03) : 233 - 237
  • [23] Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry
    Wang, JH
    Hansen, EH
    Gammelgaard, B
    TALANTA, 2001, 55 (01) : 117 - 126
  • [24] Flow injection on-line displacement sorption preconcentration coupled with flame atomic absorption spectrometry for the determination of trace lead in biological samples
    Han De-Man
    Jia Wen-Ping
    Liang Hua-Ding
    Yan Xiu-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (11) : 1643 - 1646
  • [25] Determination of trace metals in high-salinity petroleum produced formation water by inductively coupled plasma mass spectrometry following on-line analyte separation/preconcentration
    Oliveira, Eliane Padua
    Yang, Lu
    Sturgeon, Ralph E.
    Santelli, Ricardo Erthal
    Bezerra, Marcos Almeida
    Willie, Scott N.
    Capilla, Ramses
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 578 - 585
  • [26] Ti-containing mesoporous silica packed microcolumn separation/preconcentration combined with inductively coupled plasma-mass spectrometry for the determination of trace Cr, Cu, Cd and Pb in environmental samples
    Cui, Chao
    Peng, Hanyong
    Zhang, Yanan
    Nan, Kai
    He, Man
    Chen, Beibei
    Hu, Bin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (06) : 1386 - 1394
  • [27] Determination of some rare earth elements in seawater by inductively coupled plasma mass spectrometry using flow injection preconcentration
    Vicente, O
    Padro, A
    Martinez, L
    Olsina, R
    Marchevsky, E
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (09) : 1281 - 1287
  • [28] Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples
    Jia, Xiaoyu
    Han, Yi
    Liu, Xinli
    Duan, Taicheng
    Chen, Hangting
    MICROCHIMICA ACTA, 2010, 171 (1-2) : 49 - 56
  • [29] Determination of trace cadmium in environment water samples by flame atomic absorption spectrometry using flow injection on-line preconcentration with double microcolumns
    Kang, WJ
    Liang, SX
    Jia, LH
    Xu, LQ
    Zhao, Y
    Sun, HW
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (05) : 792 - 795
  • [30] Determination of copper in saline water using flow injection on line precipitation coupled with inductively coupled plasma mass spectrometry
    Chen, HH
    Beauchemin, D
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2000, 45 (03): : 84 - 89