MULTIFUNCTIONAL CAPABILITIES OF GRID CONNECTED DISTRIBUTED GENERATION SYSTEM WITH NON-LINEAR LOADS

被引:2
|
作者
Singh, Alka [1 ]
机构
[1] Delhi Technol Univ, Bawana Rd, Delhi 110042, India
关键词
Distributed generation; load balancing; power factor correction; utility grid; voltage source converter; non-linear loads; ACTIVE-FILTER; POWER;
D O I
10.1002/asjc.1203
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with the integration of distribution energy resource (DER) connected to a three-phase grid connected system feeding a variety of loads. The DER is controlled to provide power quality improvement capabilities viz. power factor correction, harmonic reduction, voltage regulation, and load balancing, and it is realized as a voltage source converter (VSC). The developed controller is based on Synchronous Reference Frame (SRF) Theory and an energy based controller that also includes additional features viz. filtration of fundamental voltage extracted from the polluted utility grid voltages. This new controller, realized as an energy controller, is implemented over the square of the DC link voltage of the DER. The control algorithm has been tested for several power quality improvement features and works well for power factor correction, voltage regulation, harmonic reduction, and operation under unbalanced load conditions. Extensive simulation and hardware results are demonstrated on a prototype developed in the laboratory.
引用
收藏
页码:1537 / 1545
页数:9
相关论文
共 50 条
  • [31] Disturbance assessment in the grid integration of power electronic devices and other non-linear loads
    Yang, X.
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 44 - 50
  • [32] Non-linear Control of a PV System coupled to the power grid
    Ghelam, Ali
    Boudhiaf, Mohamed
    Bekai, Hamida
    Abikchi, Maria
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON APPLIED SMART SYSTEMS (ICASS), 2018,
  • [33] Characteristics of harmonic distortion and disturbance in frequency 9-150 kHz of the grid-connected rooftop photovoltaic system for various types non-linear household loads
    Marganda, N.
    Sudiarto, B.
    2ND INTERNATIONAL CONFERENCE ON GREEN ENERGY AND ENVIRONMENT (ICOGEE 2020), 2020, 599
  • [34] Enhanced control of grid-connected inverters with non-linear inductor in LCL filter
    Safamehr, Hossein
    Najafabadi, Tooraj Abbasian
    Salmasi, Farzad Rajaei
    IET POWER ELECTRONICS, 2016, 9 (10) : 2111 - 2120
  • [35] System and method for determining harmonic contributions from non-linear loads
    Mazumdar, J
    Harley, RG
    Lambert, F
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 2456 - 2463
  • [36] SYSTEM APPROACH TO FUNCTIONAL DEVICES WITH NON-LINEAR DISTRIBUTED PARAMETERS
    EGOROV, EA
    KABANOV, DA
    RADIOTEKHNIKA I ELEKTRONIKA, 1978, 23 (12): : 2557 - 2562
  • [37] SPACE SAMPLING EFFECTS IN NON-LINEAR DISTRIBUTED SYSTEM STABILITY
    JUMARIE, G
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1981, 103 (01): : 54 - 60
  • [38] SELF-CONSTRICTION OF IMPULSE IN A DISTRIBUTED NON-LINEAR SYSTEM
    MESHKOV, AN
    ZHURNAL TEKHNICHESKOI FIZIKI, 1981, 51 (12): : 2592 - 2593
  • [39] Multifunctional Converter for Power Quality and Power Flow Control in Wind Distributed Generation Systems Directly Connected to the Grid
    Braga, Filipe Nassau
    Bonaldo, Jakson P.
    Pomilio, Jose Antenor
    2014 11TH IEEE/IAS INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2014,
  • [40] The Improved vμ LMS-Based Grid Connected Solar PV System Power Flow with Abnormal Grid and Non-linear Load Conditions
    Gupta, Pavan Prakash
    Tripathi, Ramesh Kumar
    Kumar, Shailendra
    RECENT ADVANCES IN POWER ELECTRONICS AND DRIVES, VOL 2, EPREC 2023, 2024, 1139 : 261 - 277