Objective: To evaluate a new operative treatment of femoral nonunion following failed exchange nailing. Design: Retrospective review, consecutive series. Setting: Office-based orthopaedic practice. Patients: Five consecutive patients (ages 31-67 years) were referred in with a femoral nonunion following exchange nailing an average of 28 months (range 11-55) after the initial traumatic injury. The patients had undergone an average of 5 (range 2-8) previous surgeries on the femur. No patient had signs or history of bone infection or segmental bone loss at presentation. All patients had diaphyseal or diaphyseal-metaphyseal oligotrophic nonunions and had failed an average of 2 (range 1-3) previous exchange nailings. Intervention: Slow compression (0.25 to 0.50 mm per day) of the nonunion site over a new, smaller diameter nail using an Ilizarov external fixator. Main Outcomes Measurements: Clinical and radiographic evidence of bone union, ambulation, pain, residual deformity, or shortening. Results: All nonunions healed without the need for further nonunion surgery. The external fixator was removed at an average of 133 days (range 86-238 days). No deep infections occurred in any patient. All patients experienced some degree of pin site irritation. At the most recent follow-up (average 45 months; range 12-75 months), all patients had improved their functional ambulatory status and had discontinued or decreased the use of assistive devices to walk. All patients were full weight bearing. Average pain, as rated on a 0 to 10 Visual Analogue Scale, decreased from 8 of 10 before treatment to 1 of 10 after treatment. No patient experienced a clinically significant worsening of leg length discrepancy. Conclusions: Slow compression over an intramedullary nail using external fixation successfully promotes the healing of problematic femoral nonunions that have failed one or more prior exchange nailings.
引用
收藏
页码:668 / 676
页数:9
相关论文
共 40 条
  • [1] Bai MH, 1996, INT SURG, V81, P390
  • [2] Results of indirect reduction and plating of femoral shaft nonunions after intramedullary nailing
    Bellabarba, C
    Ricci, WM
    Bolhofner, BR
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (04) : 254 - 263
  • [3] Brinker M, 2003, SKELETAL TRAUMA BASI, P507
  • [4] Busse JW, 2002, CAN MED ASSOC J, V166, P437
  • [5] Christensen N O, 1973, J Bone Joint Surg Br, V55, P312
  • [6] Cook SD, 1999, ORTHOPEDICS, V22, P669
  • [7] No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures
    Emami, A
    Petrén-Mallmin, M
    Larsson, S
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (04) : 252 - 257
  • [8] Exchange nailing for femoral shaft aseptic non-union
    Furlong, AJ
    Giannoudis, PV
    DeBoer, P
    Matthews, SJ
    MacDonald, DA
    Smith, RM
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (04): : 245 - 249
  • [9] GREEN SA, 1994, CLIN ORTHOP RELAT R, V301, P111
  • [10] Success of exchange reamed intramedullary nailing for femoral shaft nonunion or delayed union
    Hak, DJ
    Lee, SS
    Goulet, JA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (03) : 178 - 182